You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 52 Next »

Target Release Date  

Final edits due  

Introduction

HE update

Roles and Team update

L2HE Project Roles and assignment table can be found here.

MECU-update

Rack allocations

Other controls requirements

LLE+LLNL Visit

Hutch Python Update

Hutch python's conda environment was updated to pcds-5.3.1 near the start of April

You can read the full release notes here: PCDS Conda Release Notes: pcds-5.3.1

Robert S. Tang-Kong Zachary L Lentz 


New Dual-Acting Valve Widget

Dual acting valves are now integrated into pcdswidgets with a nice looking icon to represent the functionality of the valve.

Extensive documentation on the process of making a new pcdswidget was provided as well as scripts for testing widgets in development.

Position Lag Monitoring

  • Add metric plots
  • Add any conclusions drawn regarding this issue, and corrections.
  • Would be nice to see the counts trending down on account of some PLM threshold changes.

Zachary L Lentz Tyler Johnson 

Lightpath Campaign

Lightpath is a tool that aims to show users and scientists which components are blocking the beam path, greatly expediting troubleshooting and recovery of operation.  

Unfortunately the tool has been plagued with bugs and efficiency issues for quite some time.  We are planning a substantial rework of the tool, with the goal of making the tool available for all hutches.  

A JIRA Epic has been created to gather existing lightpath issues/bug reports.  If you have ideas for features or bugs to report, feel free to add an issue to the epic.  We will be basing the re-design on requested features, so submitting an issue now is the best way to see those issues solved.  We will continue to reach out for input throughout development, so be ready to hear from us!

New ECS PD Campaign: Code Review

ECS currently has nearly all of our hutch-python and related Python source code in the pcdshub organization on GitHub.
We utilize a standardized workflow that improves understanding among our team, provides automated quality and style fixes, and in the end results in a higher quality set of code.

We want to take our same standards that we apply to Python development and bring it forward to nearly all PLC, EPICS module and EPICS IOC development.
This will be an ongoing effort over the course of months.

See more details on the initiative page here - ECS GitHub and Code Review Campaign - feedback is welcome.

ATEF Status Update

We are continuing on our refocused ATEF development effort, targeting passive testing of control system devices. The "passive" portion of this means that it will be fully-automated and non-intrusive (that is, it will not move your motors or otherwise directly cause a PV to change).

We are making progress on the user-facing components of atef for passive checks. This includes a work-in-progress set of GUI elements, allowing for a more straightforward specification of a passive checkout configuration, with a happi device search tool and ophyd device inspector. A preliminary command-line based passive check running tool has also been developed.

image

Future development will include: active tests (guided, with humans in the loop) including integration with bluesky, a synoptic for viewing the atef-reported status of all devices, integration with Grafana, views of devices in typhos/hutch-python at a given time in the past, and many other things.

shared-dotfiles

What are dotfiles?

  • Dotfiles are configuration files that sit in your home directory, like .bashrc.
  • Dotfiles set per-user configuration settings for different applications, like the text editor vim or your shell.
  • If you have a unix account, you likely have dotfiles in your home directory on pslogin, whether you have customized them or not.

In a survey of users' configurations, we found that many were similar, likely copied and tweaked from one user's home directory to another when they joined ECS.
In some strange form of the telephone game, a bit of meaning was lost between each successive copy, with configuration lines remaining with not a clue as to why they were there.

We then set off on a goal to create a shared repository that allows for a good starting point for new engineers, or existing ones that want to improve (or just better understand) their settings.
Almost every line contains an explanation as to why it is there, with some offering suggestions as to how to adjust it to your preference.

Here is a link to that repository:

https://github.com/pcdshub/shared-dotfiles

It includes a variety of suggested configuration files for various basic tools like ssh, bash, vim, and so on that ECS staff and others who use the same computing infrastructure may find useful.
It also explains a bit about what scripts are available and how to better navigate your environment in its documentation.

QRIX Controls

Margaret Ghaly Jyoti, Joshi 


Spectrometer Arm.mp4


The Spectrometer Arm has been installed and checked out. The spectrometer arm has a total of 27 axes installed with coupled and coordinated motion with strict EPS requirements. The acceptance test went very well with Toyama and even were complete ahead of schedule.

The QRIX vacuum PLC code has been merged with that of the spectrometer arm. The vacuum controls integration is complete for all the installed devices.

TXI

Cables were successfully pulled in the FEE for patch panels for both K and L lines. 

TMO

First deployment of VAT590 variable valve in LAMP. Jing Yin Govednik, Janez Maarten Thomas-Bosum 

This was used with the Magnetic Bottle (MBES) iteration of the LAMP endstation.





TMO requested this very-low flowrate leak valve for experiment gas delivery and vacuum level control in the IP1 chamber. 

The valve plate acts as a throttling element and varies the conductance of the valve opening.

Actuation is performed with a stepper motor and controller. The stepper motor/controller version ensures accurate pressure control due to exact gate positioning. The onboard controller and built-in PID loop were integrated into the control network of the LAMP vacuum PLC and IOC, and a custom PyDM GUI was developed as a user interface for this device.

In the future, this device will be integrated into the vacuum control systems of other endstations in TMO. Furthermore, work will be done to allow users to set and tune the PID loop parameters themselves, which are currently locked into the lower level CoE settings. This is because the control loop needs to be adjusted for chambers of different volume, gas flow rate etc.

Documentation page: LAMP MBES Variable Leak Valve Commissioning 3/22

Facility Monitoring System Update

Cynthia Melendrez Tyler Johnson 

Radiation Monitoring in the FEE

FEE Radiation Monitoring

We began taking initial Radiation measurements in the FEE! From four different locations we gained 2 sensor readouts each. Here we see Hard Xray beam energy mapped against dose rates.

A shift was made to bring the rest of the sensors online. Looking forward to collecting more data this month!

X-ray Optics Controls Updates

MR1L3, MR2L3, and MR1L4 XRT HOMS  Mirrors

    • Temperature sensors added to XRT HOMS Temperature
    • State Control fully implemented! We can now reach mirror coating positions and move the mirrors in and out of the beam with one click!

MR1K4 FEE TMO Mirror

  • Newly upgraded with coating state control.
  • PMPS states implemented. 

MR3K4, MR4K3, MR2L1, and MR3L1 TXI Mirror

MR4K4, MR5K4 TMO DREAM Mirror

  • Granite installed/Mirror moved into the hutch.
  • Controls fully checked out: DREAM Install
  • Coming: Internal RTD, Pressure, and Flow Sensors.

MR2K4, MR3K4 TMO LAMP Mirror

  • Look for some higher performance in the axis control
  • Control loops changed and Deadbands tightened

Experiment State Tracker and Eloggrubber

Based on popular demand, the Experiment State Tracker has been integrated with the eloggrubber and the possible state list has been extended (with much more detail for 'instrument down' in particular.)

The eloggrubbers JIRA implementation has changed to allow automatic assignment to the instruments as well as posting of the attachments Murali Shankar

Grafana has also been extended to allow the creation of piechart data from the archived Experiment State Tracker output.

Jungfrau [0.5/1]M IOC

The smaller jungfrau detectors which use a Rohde-Schwartz power supply now have an IOC (ioc/common/roving_jf) to make the process of turning them on/off consistent with the various epix-detectors. This IOC will trip the detector should a problem with the chiller flow or power supply is detected.

Jungfrau4M Tripper

Tyler NT Pennebaker 

Timing moves to RHEL7

Christina Pino 

CSU Chico Engineering Capstone Collaboration

Alex Wallace 

This year Diling Zhu has sponsored the collaboration project (many thanks Diling!), which is to develop a prototype system for determining interaction point alignment using machine vision. In early March, the CSU Chico Engineering Capstone Collaboration project team visited XPP to do some final fit measurements around the interaction point for installation of their project later this year.

For the past five years LCLS departments (SED and ME) have sponsored projects with the Mechanical/Mechatronic Engineering departments of CSU Chico for their engineering degree capstone. Each year the collaboration project offers a chance for  LCLS to develop prototype concepts, or even to offload a manageable portion of work to a team of 4-5 students and a faculty advisor (for a nominal fee + M&S). More importantly these projects offer us a chance to discover talented candidates that we can hire. If you have an idea for a project, please contact Alex Wallace for details. On a final note, this year we are excited to announce that we hired another student from the collaboration project, Mitchell Cabral. He will join ECS as a control system integrator in June.


HXR Single Shot Spectrometer Updates

Spencer, Aalayah I 

Restoration of the HXR spectrometer mechatronics has been completed and has successful commissioning times. The spectrometer has been a vital part in experiments including those in MFX. Included below are some images taken from the orca camera. Further updates to the gui have been made including ways to power cycle devices as well provide an easier way to access the webcam used for remotely viewing how the spectrometer is behaving.

Full design and motion system details can be found here


Hutch Rack Cleanup Efforts


IT Updates

Spencer, Aalayah I Omar Quijano 

Network Reorganization

WEKA HOME/FFB Cluster Upgrade

Workstations and Servers Matrix

Remote Operations Hardware Maintenance Schedule

Integrate UED to LCLS Standards

New Ciara Purchase

*ioc-xrt-rec07

*SRCF Data Mover Bandwidth Upgrade

*GNOME Key Binding Shortcuts

UPCOMING

Batch Nodes

DSS Nodes

CXI Network Upgrade

Switch Tool

Diskless Server Upgrade

Diskless Monitoring

750 Pit Cleanup Progress

Omar Office Cleanup Progress (per DFlath) LOL ?!

Jira


P Summary Resolution Created Resolved Reporter Assignee
Loading...
Refresh

  • No labels