Performance Measures

Pedestal Summary

Method:  Dark environment, nominal operation, collect 1000 frames @120Hz.  Generate per-pixel mean and standard deviation over 1000 frames.  Pixels more than 3 sigma out of detector-wide mean are flagged bad.  Files archived as xxxx.

Map of pedestal non-conforming pixels for all gain modes here

Gain Mode

Mean Pedestal Value (ADU)

Number of NCP

Pixels Map, Histogram
FH3204 ± 2444938Graphs
FM3167 ± 2344956Graphs
FL3149 ± 2304967Graphs
AHL3209 ± 2424939Graphs
AML3169 ± 2344956Graphs


Noise Summary

Map of noise non-conforming pixels for all gain modes here.  

Gain ModeVariation (ADU)Number of NCPPixels Map, Histogram
FH61388Graphs
FM31612Graphs
FL211828Graphs
AHL748Graphs
AML31056Graphs     


Gain and uniformity (photon source)

Map of gain non-conforming pixels for all gain modes here

Gain ModeNumber of NCP
FH0
FM0
FL4096
AHL116
AML34

Configuration Settings

  

Linearity (signal injection)

Thermal measurements (all thermometers)



  • No labels