Issue | Description | Date Added | Added by | Actions Taken | Status |
---|---|---|---|---|---|
FEB chiller | Disconnected after found dirty | 5/6/2019 | tkn | Replaced, new chiller plumbed in and running. Serial control is up but needs testing. | unresolved |
Wiener LV card | Card won't power - slot 4. On initial look, slots 4+ in crate had no power | 5/8/2019 | tkn | Swapped in spare card located in slot 10. See logbook entry | resolved (OM) |
FEBs | Not all working | 5/8/2019 | tkn | unresolved | |
Cable Labels | Label cabels to SVT/FEB chillers | 5/8/2019 | mrsolt | unresolved | |
Chiller Serial Cable | Redo spliced connections of the serial cable to SVT/FEB chiller | 5/8/2019 | mrsolt | unresolved | |
SVT Chiller Webcam | Setup the SVT chiller webcam to monitor fluid levels | 5/8/2019 | mrsolt | unresolved | |
Checked motor decoders | Need to understand if motor decoders need to be replaced | 5/9/2019 | omoreno | unresolved | |
Check motor controller | Verify that motor moves the expected distance when moved from the GUI | 5/9/2019 | omoreno | unresolved | |
Re-set motor home and operation position | New layer 0 modules requires resetting motor positions. | 5/9/2019 | omoreno | unresolved | |
Add SVT variables to EPICS | Before, values were retrieved by parsing the XML. Now, rogue will provide us the variables directly. | 5/9/2019 | omoreno | unresolved | |
Add RTD to SVT Chiller outlet | We have a broken RTD on the SVT chiller outlet, and we should replace it | 5/9/2019 | mrsolt | unresolved |