You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 7 Next »

LAT CU Heavy Ion Beam Test at GSI - Run Plan

Motivations

The CU Beam Test at GSI is part of the general beam test program of the GLAST LAT CU.
The main goal of the program is to support the LAT Instrument Calibration by providing direct measurements of the physical processes taking place in the CU detector when exposed to different beams, by comparing the obtained measurements with Monte Carlo predictions and by eventually validating the full LAT MC code used to provide instrument calibrations and background rejection strategies.

The first part of the program took place at CERN using a variety of different particle beams (e, e+, p, pions, photons) and ranging in energies from tens of MeV up to hundreds of GeV.
The second part of the program exploits the high energy heavy ion beams available at GSI to measure the response of the CU to such radiation. Heavy ions are an important component of primary cosmic rays, and the LAT plans to use them to calibrate the CAL and ACD subsystems during flight operations. Therefore the GSI test is primarily meant to verify the on-orbit calibration procedure for the CAL, which uses also the ACD and TKR subsystems for triggering and tracking.
The CU beam test at GSI is also a first test with heavy ions for the TKR subsystem.

List of measurements

Below is a partial list of topics of interest, grouped per subsystems

TKR: saturation effects from heavy ions on ToT signal, tracking performance, instrument deadtime
CAL: verification of quenching factors (measured at GSI 2003), test on-orbit calibration procedure and code
ACD: verification of CNO trigger, verify ACD dynamic range

General overview of the run

The run at GSI is scheduled between november 15 and november 20, with beam avaialble between november 18 8AM and november 19 8PM.
Installation and debug will take place on november 15, 16, 17.

Below is a table summarizing the standard operating mode agreed with GSI. Specific run conditions can be agreed and must be defined beforehand (see detailed run schedule)

Run period

Operation mode

Ions

Energy

Rate

18/11-8AM 19/11-8PM

parasitic mode to therapy for daytime (approx 20 min irradiation with 20 min break), timesharing with other experiment overnight

C, Xe (probably on 19 anytime)

1.5GeV/n

O(100)Hz/cm^2

The beam focus can be moved from a few meters upstream the detector down to the CU location, in order to enlarge or squeeze the beam spot. This feature can also be used to decrease/increase particle density.

Trigger considerations

Since the allocated beam time is not very much, we should exploit the capability of operating the CU with multiple trigger engines. Moreover, effects like pedestal drift and different investigations to be performed, suggest that we run in such mode to cover more topics in a short data-taking time.
Multiple trigger engines worked with the CU both at CERN-SPS and at INFN with CR tests.
Such operation will be verified again at GSI, with CR and beam, to make sure that the CU operates in the expected way and we can proceed with the test in such mode.

The CNO trigger, in combination with TKR and CAL triggers will be the main trigger for the test. Some runs will be taken with external trigger, others will be taken with standard internal trigger made with TKR and CAL primitives.
A periodic trigger, with variable frequency, will be in parallel to the main particle trigger for most of the runs, in order to sample the hardware status with random triggers.

Below is the list of proposed engines:

*BT42

Trigger

Readout configuration

CNO&&TKR&&CAL-LO

4-range, NZS

periodic(5Hz)

4-range, NZS

*BT43

Trigger

Readout configuration

CNO&&TKR&&CAL-LO

auto-range, ZS

periodic(5Hz)

4-range, NZS

*BT44

Trigger

Readout configuration

CNO

4-range, NZS

periodic(5Hz)

4-range, NZS

*BT45

Trigger

Readout configuration

TKR or CAL

auto-range, ZS

periodic(5Hz)

4-range, NZS

List of runs

Below is a list of specific run requests. Plese update the table and notify Luca so that a proper run schedule can be developed and agreed with GSI

Purpose

preferred schedule

Ion

Energy

Rate on CU

Beam focus

CU configuration

Trigger

notes

reference

Test multiple trigger engines prior to beam

nov 16-17

NA

NA

NA

NA

enable multiple trigger engines

CNO, periodic, internal trigger

take runs at different CNO thresholds, periodic trigger frequency

luca

Test multiple trigger engines w beam

nov 18

C

1.5Gev/n

100Hz

any

enable multiple trigger engines

CNO, periodic, internal trigger

take runs at different CNO thresholds, periodic trigger frequency

luca

Monitor beam rate and conditions

nov 18

C

1.5Gev/n

10-1000Hz

play with focus to change beam intensityon CU

4 range readout, non zero suppression

external

to be repeated shortly per configuration change

luca

Rate scan

after multiple engine work

C

1.5Gev/n

10-1000Hz

play with focus to change beam intensity on CU

multiple trigger engines, ZS

CNO, periodic, internal trigger

vary periodic trigger frequency to induce pedestal drift

luca, eric g

Tracking performance

any time

C,Xe

1.5Gev/n

10-1000Hz

far and near focus

multiple trigger engines, flight settings, 4range-readout ZS

CNO, internal trigger

investigate tracking at different rates and angles (0,30,45,60 TBD)

leon, INFN

Tracking saturation

any time

C,Xe

1.5Gev/n

10-1000Hz

far focus

multiple trigger engines, flight settings

CNO, TKR trigger, 4range-readout ZS

scan different angles (0,30,45,60 TBD)

leon, INFN

CAL calibration

nov 18

C,Xe

600MeV/n, 1GeV/n, 1.5GeV/n

100Hz

far and near focus

multiple trigger engines, ZS

CNO, periodic, internal trigger

verify quenching factors, CAL calibrations, ACD partial calibration

CAL team

CAL calibration comparison with previous results

nov 18

C,Xe

1.5GeV/n

100Hz

far and near focus

software trigger

4range, ZS

beam on tower1 to avoid TKR in the line

CAL team

Energy scan

nov 19

C,Xe

100MeV/n - 1.5GeV/n in steps

10-1000Hz

far and near focus

multiple trigger engines

CNO, periodic, internal trigger

attempt to simulate different ions by varying ionization energy

nicola

Secondary ions with target

nov 19

Xe

1.5GeV/n

10-1000Hz

far and near focus

multiple trigger engines

CNO, periodic, internal trigger

attempt to get different ions by shooting beam through a target

benoit

Charge injection in CAL with beam

nov 19

C

1.5GeV/n

10-1000Hz

far and near focus

software trigger

4range, NZS

check pedestal restoration with beam ON, explore different beam rates; can use existing CalibGenCAL script

sasha

Charge injection in TKR with beam

nov 19

C

1.5GeV/n

10-1000Hz

far and near focus

software trigger

4range, NZS

check rate effect in TKR signal; must identify CI script and plots to monitor

leon, TKR team

TOT saturation

nov 19

C

1.5Gev/n

100Hz

far focus

multiple trigger engines, flight settings

CNO, TKR trigger, 4range-readout ZS

try increasing TOT dynamic range by working with sys clock at 5MHz - need to first proof feasibility, find proper timing

robert, nicola

  • No labels