You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 8 Next »

Content

Optical measurements

Quality check

Quality check table for original metrology file

pair:        S1      S2     dS1     dS2        L1      L2     dL1     dL2    <dS/L>  angle(deg)      D1      D2      dD   d(dS)   d(dL)    dz3(um)

Quad  0
pair: 0   20910   20910    -180    -180     43550   43540      90      80   -0.00413   -0.23684   48304   48306      -2       0      10     99.997
pair: 1   20920   20920    -200    -200     43560   43630      10      80   -0.00459   -0.26285   48309   48401     -92       0     -70    100.033
pair: 2   20910   20100      10     820     43550   43540      10       0    0.00011    0.00658   47960   48305    -345    -810      10   1724.336
pair: 3   20910   20900    -140    -130     43540   43530     -60     -70   -0.00310   -0.17767   48294   48294       0     -10      10      9.995
pair: 4   20900   20910    -220    -210     43540   43550      90     100   -0.00494   -0.28289   48296   48311     -15     -10     -10    -69.579
pair: 5   20920   20900      40      20     43200   43550     -20     330    0.00069    0.03968   48304   47999     305      20    -350     34.059
pair: 6   20910   20910    -130    -130     43530   43540     -70     -60   -0.00299   -0.17109   48294   48298      -4       0     -10      0.002
pair: 7   20910   20909    -130    -129     43540   43540     -60     -60   -0.00297   -0.17041   48302   48298       4      -1       0    -30.000

Applied corrections

  • pair 1: Correction to point 2: x+0.07mm; 0.01 → 0.08
  • pair 2: Correction to point 16: x−0.8mm;  44.63 → 43.83
  • pair 5: Correction to point 24: x+0.35mm;  90.62 → 90.97

Gabriel Blaj reported that "Z deviations larger than ~150 micron are typos, or the metrology microscope focussing on the wrong surface. Please use the other 3 and assume a
flat surface to extrapolate the real Z". So, we apply Z correction: 

  • point 13 Z=−1.76 → 0
  • point 17 Z=−1.75 → 0
  • point 18 Z=−1.80 → 0
  • point 21 Z=−1.76 → 0
  • point 22 Z=−1.75 → 0

Quality check table for corrected metrology file

pair:        S1      S2     dS1     dS2        L1      L2     dL1     dL2    <dS/L>  angle(deg)      D1      D2      dD   d(dS)   d(dL)    dz3(um)
Quad  0
pair: 0   20910   20910    -180    -180     43550   43540      90      80   -0.00413   -0.23684   48304   48306      -2       0      10     99.997
pair: 1   20920   20920    -200    -200     43560   43560      80      80   -0.00459   -0.26307   48309   48338     -29       0       0    100.000
pair: 2   20110   20100      10      20     43550   43540      10       0    0.00011    0.00658   47960   47964      -4     -10      10     39.998
pair: 3   20910   20900    -140    -130     43540   43530     -60     -70   -0.00310   -0.17767   48294   48294       0     -10      10      9.995
pair: 4   20900   20910    -220    -210     43540   43550      90     100   -0.00494   -0.28289   48296   48311     -15     -10     -10    -20.009
pair: 5   20920   20900      40      20     43550   43550     -20     -20    0.00069    0.03947   48304   48314     -10      20       0     10.000
pair: 6   20910   20910    -130    -130     43530   43540     -70     -60   -0.00299   -0.17109   48294   48298      -4       0     -10      0.002
pair: 7   20910   20909    -130    -129     43540   43540     -60     -60   -0.00297   -0.17041   48302   48298       4      -1       0    -30.000

Geometry parameters

Parameters for center and tilt are available in

/reg/neh/home1/dubrovin/LCLS/CSPadAlignment-v01/calib-mec-2013-12-20/*/0-end.data

 

Summary

  • X coordinates are corrected for points 2, 16, 24
  • Z coordinate is corrected for points 13, 17, 18, 21, 22
  • After that all deviations are ~10um.

 

References

 

 

 

 

 