Proposal for precise geometry parametrization of planar imaging detectors.

Content

 

Coordinate system for setup

Axes definition

Cartesian coordinate system of setup is defined by three mutually orthogonal right-hand-indexed axes with origin in the interaction point (IP) of the photon beam with sample:

  • X – pointing from IP to the north,
    Y – pointing from IP to the top, and
    Z – pointing from IP along the photon beam propagation direction,

as shown in the plot:

                             

 

Each photon with sample collision happens in different place... IP is an abstract position of the crossing point of the "beam line" and "target", which both are not well defined... Is it really good definition?

 

Detector position

Detector coordinate system may have a translation and rotation with respect to the setup, which can be defined by the 3 vectors in the setup frame:

  • P – translation vector pointing from IP to the detector origin,
  • ex – unit vector along the detector frame x axis,
  • ey – unit vector along the detector frame y axis,

as shown in the plot:

                                         

Third unit vector ez – is assumed to be right-hand triplet component,

               ez=[ex × ey].

Components of these three unit vectors form the matrix eij, where indexes "i" and "j" corresponds to the vector components in the setup and detector local coordinate frames, respectively. Within this definition 3-d pixel coordinate "c" in the detector frame can be transformed to the setup coordinate "C" using equation

                              Ci=eij·cj + Pi.

 

 

Coordinate system of the detector

In this note we assume that:

  • the detector image is produced by a set of tiles (a.k.a., segment, section, 2x1, sensor, Si-pixel matrix, etc),
  • the tiles form almost flat (x-y) surface around z=0 within precision of production technology and installation,
  • the tile rotation angles in (x-y) are N*90 degrees, where N=0,1,2,or 3,
  • detector local coordinate system is defined in this plane, as explained below.

These assumptions are not necessary for most of algorithms. But, in many cases it may be convenient to use small angle approximation or ignore angular misalignment for image mapping between tiles and and 2-d image array.

 

Tile ideal geometry

  • Each tile has well defined by design geometry of pixels, which does not need in separate calibration.
  • Pixel center (x,y) coordinates at z=0 for each tile can be defined as a look-up table in its "natural" matrix-style coordinate system.
  • For example, CSPAD 2x1 tile pixel geometry is defined as

           

  • Regular pixels have size is 109.92 x 109.92 µm2,
  • Pixel size in two middle columns 193 and 194 is 274.80 x 109.92 µm2.

 

Memory model

It is assumed that each tile is presented in DAQ or offline data by a single block of memory.  Uniform matrix-type geometry of pixel array is preferable, but  other geometry can be handled, for example like in CSPAD 2x1 sensor. Detector data record consists of consecutive tile-blocks, in accordance with numeration adopted by DAQ. For effective memory management, some of the tile-blocks may be missing due to current detector configuration. Available configuration of the detector tile-blocks should be marked in a  bit-mask word in position order (bit position from lower to higher is associated with the tile number in DAQ).

For example, consecutive pixel index in the CSPAD 2x1 tile memory block of size (185,388) is

                         i = col + row*388.

Optical measurements

  • Optical measurements provide 3-d coordinates of 4 corners for all tiles in the detector in some arbitrary microscope plane which coincides with detector imaging array (tiles) plane within precision of installation.
  • Tile corner coordinates do not necessarily coincide with corner pixel centers or edges.
  • Numeration of tiles should not necessarily coincide with their numeration in DAQ, but it should be done in fixed order or with indication of tile numbers:
  • Optical measurements provide a list of coordinates for all sensor points:

    Tile #
    Point #X[µm]Y[µm]Y[µm]

Quality check

Quality check of optical measurement may include for each tile:

  • equity of opposite sides
  • equity of diagonals
  • equity of tilt angles for all sides
  • tile flatness in 3-d

Position of tiles in the detector

Detector pixels' geometry in 3-d can be unambiguously derived from

  • the list of coordinates obtained in optical measurements,
  • tile ideal geometry, and
  • designed orientation of tiles in the detector.

The tile location and orientation can be defined by the table of records

Tile #Xc[µm]Yc[µm]Yc[µm]Rotation angle [degree]Tilt in X-Y[degree]Tilt in Y-Z[degree]Tilt in X-Z[degree]

where

  • Tile # –  Tile number in DAQ
  • Xc, Yc, and Zc[µm] –  tile center coordinates in micrometers
  • Rotation angle [degree] – tile rotation angle in X-Y detector plane in degrees, presumably it is N*90, where N=0,1,2,3
  • Tilt in X-Y,  Y-Z,  X-Z[degree] – small angles for correction of the tile orientation w.r.t. design rotation angle

Tile center coordinates are defined as an average over 4 corners.

Tilt angles are projected angles of the tile sides on relevant planes. Each angle is evaluated as an averaged angle for 2 sides.

Summary

Suggested method for imaging detector geometry description provides simple and unambiguous way of pixel coordinate parametrization. This method utilizes all available information from optical measurement and design of the detector and tiles. All geometry parameters are extracted without fitting technique and presented by natural intuitive way.

 

 

 

 

 

 