System Tests Report Summary
Comparison to v14r2 shows differences in the ACD digis. Examples shown below – this seems to reflect Eric's fix to handling pulses below the zero suppression threshold.
The comparison is made to v14r2 instead of v14r3, which was interrupted mid-build by the weekend computing outage.
Changes
- AcdDig - kill PHA below zero suppression threshold
- Catching up many packages
- Updates for JIRA ROOT-34, ACD-19 and GRINF-46
- Updates for DFI 3-4-5
ACD Digi Plots
All of the system tests (except the vertical muons) show a similar change in the ACD digi ADC plots. You can see increase in zeros and suppression of sub-zero suppression threshold pulses. (Shown below for the AllGamma test.)
In some cases the ribbon MIPs plot has changed in a similar manner (AllGamma shown).
The VerticalGamma100MeV test shows a difference in the ACD digi total sum (below).