- The following error is aperiodically seen when exiting the ScriptEngine (09/27/05):
C:\projects\LICOS\start>scriptEngine.bat --server lat-elf21 --config scriptEngine.cfg INFO:root:Trying to connect to the message logger INFO:root:Successfully connected to the message logger INFO:root:Connection to CVT failed. User scripts that call the CVT may fail Receiver server 1516 (134.79.129.208:4876) created Receiver server 1484 (134.79.129.208:4878) created Receiver server 1444 (134.79.129.208:4881) created Receiver server 1424 (134.79.129.208:4882) created INFO:root:FSMactionEngine: terminating INFO:root:ScriptEngine: terminating Error in sys.excepthook: Original exception was: C:\projects\LICOS\start>
This is probably due to the ScriptEngine not gracefully terminating some VSC originated threads.
- When working with the testbed powering off and on the SIU requires the TelemetryProxy to be restarted (09/27/05).
- When working with the testbed, the following message was observed on the DiagnosticProxy (09/27/05):
*** Receiver max number servers (1) reached