Optical measurement
We use before-run4 optical measuremens from Chris 2011-06-20 file.
Procedure and table of results
We calculate
S1 - 1st short side of 2x1
S2 - 2nd short side of 2x1
L1 - 1st long side of 2x1
L2 - 2nd long side of 2x1
dS and dL are the deviations of the 1st and 2nd corner along the short and long sides, respectively. The sign of all dS are chosen in order to provide correct sign for the tilt angle (the same direction for all 2x1 sensors).
Everything, excluding <dS/L> and angle(deg), are in micrometers.
S1 S2 dS1 dS2 L1 L2 dL1 dL2 <dS/L> angle(deg) Quad 0 pair: 0 20911 20907 -255 -259 43543 43539 130 126 -0.00590 -0.33819 pair: 1 20907 20905 2 0 43536 43535 4 3 0.00002 0.00132 pair: 2 20905 20909 241 237 43537 43539 112 114 0.00549 0.31452 pair: 3 20894 20903 -22 -31 43540 43542 -10 -8 -0.00061 -0.03487 pair: 4 20906 20908 111 113 43539 43543 -55 -51 0.00257 0.14738 pair: 5 20899 20911 54 66 43545 43533 -23 -35 0.00138 0.07896 pair: 6 20908 20911 -164 -167 43544 43538 -74 -80 -0.00380 -0.21778 pair: 7 20905 20897 -83 -75 43541 43539 -38 -40 -0.00181 -0.10396 Quad 1 pair: 0 20907 20911 -209 -205 43542 43544 100 102 -0.00475 -0.27238 pair: 1 20904 20892 4 -8 43550 43544 0 -6 -0.00009 -0.00526 pair: 2 21372 21379 23 16 43903 43909 1 7 0.00044 0.02545 pair: 3 21379 21382 25 22 43908 43909 11 12 0.00054 0.03066 pair: 4 20915 20906 -23 -32 43535 43543 7 15 -0.00063 -0.03619 pair: 5 20908 20911 17 20 43540 43541 -12 -11 0.00042 0.02434 pair: 6 20904 20900 59 63 43538 43540 28 30 0.00140 0.08027 pair: 7 20901 20900 114 115 43543 43537 53 47 0.00263 0.15067 Quad 2 pair: 0 20910 20905 -34 -39 43540 43548 12 20 -0.00084 -0.04803 pair: 1 20908 20896 3 -9 43539 43537 0 -2 -0.00010 -0.00592 pair: 2 20912 20900 80 92 43536 43536 43 43 0.00198 0.11318 pair: 3 20906 20908 -59 -61 43539 43542 -31 -28 -0.00138 -0.07896 pair: 4 20900 20903 -276 -273 43538 43536 139 137 -0.00630 -0.36125 pair: 5 20895 20899 -244 -240 43538 43540 114 116 -0.00556 -0.31846 pair: 6 20905 20901 -127 -123 43388 43278 56 -54 -0.00288 -0.16527 pair: 7 20902 20893 66 75 44415 43465 -34 -984 0.00161 0.09200 Quad 3 pair: 0 20904 20897 98 91 43538 43536 -42 -44 0.00217 0.12436 pair: 1 20909 20904 4 -1 43534 43529 5 0 0.00005 0.00263 pair: 2 20902 20907 343 338 43540 43537 162 159 0.00782 0.44809 pair: 3 20904 20896 192 200 43539 43537 97 95 0.00450 0.25794 pair: 4 20906 20908 -138 -136 43533 43542 61 70 -0.00315 -0.18029 pair: 5 20906 20768 68 -70 43404 43542 28 166 -0.00002 -0.00117 pair: 6 20905 20900 246 251 43541 43540 119 118 0.00571 0.32701 pair: 7 20908 20905 245 248 43540 43536 121 117 0.00566 0.32439
- The only problematic measurement is for Quad 3, pair 5.
- All other are consistent with each other within
+/-10um
. - Angles of 2x1 are in the range from
-0.46
to+0.44
degree.
Configuration parameters
Configuration parameters are shown in number of pixels.
For 2x1 pairs in each quad
Coordinates of the 2x1 centers (the same orientation as in optical measurement, center is calculated as an average of 4 corner coordinates)
self.pairXInQaud = [[199.14, 198.05, 310.67, 98.22, 629.71, 629.68, 711.87, 499.32], [198.52, 198.08, 311.50, 98.69, 627.27, 627.27, 712.35, 499.77], [198.32, 198.04, 310.53, 97.43, 626.68, 628.45, 710.86, 498.01], [198.26, 198.04, 308.70, 96.42, 627.66, 628.04, 711.12, 498.25]] self.pairYInQaud = [[308.25, 95.11, 625.60, 625.70, 515.02, 727.37, 198.53, 199.30], [307.18, 95.08, 622.98, 623.51, 514.99, 727.35, 199.27, 198.94], [307.68, 95.09, 623.95, 625.29, 512.32, 724.63, 198.04, 200.35], [307.39, 95.12, 627.57, 626.65, 518.03, 730.95, 200.02, 199.70]] self.pairZInQaud = [[ 0.31, 0.12, 0.05, 0.12, 0.28, 0.24, 0.40, 0.27], [ 0.45, 0.36, 0.62, 0.33, 1.02, 0.92, 1.30, 1.07], [ 0.23, 0.22, 0.11, 0.15, 0.24, 0.20, 0.60, 0.42], [ 0.25, 0.21, 0.12, 0.10, 0.35, 0.28, 0.66, 0.40]]
Hand-maid coordinate correction for 2x1 in quads
self.dXInQaud = [[ 0, 0, 0, 1, 1, 0, 1, 0], [ 0, 0, 0, 0, 0, 0, -1, 0], [ 0, 0, 0, 0, 0, 0, 0, 0], [ 0, 0, 0, -1, 0, 0, 0, 1]] self.dYInQaud = [[ 0, 0, 0, 0, -1, 0, -1, 0], [ 0, 0, 0, 0, 0, 1, 0, 0], [ 0, 0, 0, 0, 0, 0, -1, -2], [ 0, 0, 0, 0, 0, 0, 0, 0]]
2x1-pair orientation in quads
self.pairInQaudOrient = [ [ 270, 270, 180, 180, 90, 90, 180, 180], [ 270, 270, 180, 180, 90, 90, 180, 180], [ 270, 270, 180, 180, 90, 90, 180, 180], [ 270, 270, 180, 180, 90, 90, 180, 180] ]
Sensor tilt angle (dergee) from optical measurement
self.dPhi = [ [-0.33819, 0.00132, 0.31452, -0.03487, 0.14738, 0.07896, -0.21778, -0.10396], [-0.27238, -0.00526, 0.02545, 0.03066, -0.03619, 0.02434, 0.08027, 0.15067], [-0.04803, -0.00592, 0.11318, -0.07896, -0.36125, -0.31846, -0.16527, 0.09200], [ 0.12436, 0.00263, 0.44809, 0.25794, -0.18029, -0.00117, 0.32701, 0.32439] ]
For quads in the detector
TBA