  1. Turn dry-air valve counterclockwise ¼ turn.
    There should be a hissing noise from the air flow.

    Info

    This dry air is used to control EFD and height gauge.

  2. Turn EFD on
    The screen will display a default menu. [Add picture.] 
    The settings for SE4445 are preset 001



    Image Added

  3. Turn on glue robot.
    The robot head should be in such-and-such position.
    Image Added


  4. The ITkPixel account on the PC has the Janome Points software installed to control the robot. 

    Info

    The password is AtlasITkBox. For info about the itk-admin account contact Matthias Wittgen

  5. Click on the desktop icon JR C-Points to start the program
    PointIcon.png
  6.  Select the following options to initialize the program :  

    •  JR2500-N bullet 
    •  z-axis control 
    •  R-axis control (not ticked!)
    •   IO-A (not ticked) 

      See picture for comparison: 


  7. Open the point program Neha_2020Feb3_InnerRingx3.cpd

    Info

    We are using #13 for the triplet in a row.

    Note that the pallet routine is #22 (plane, with auto-increment)

     



  8. Initialize the robot with Meca Initialize



  9. To execute the program hit Send C&T data from the Robot menu. 

    Info

    Make sure that the Robot is set in Teaching mode in the Changing Mode window from the Robot menu.

  10. Select Switch Run Mode in the Changing Mode window from the Robot menu.

  11. Select the program #  to execute from the Robot command buttons. It will be displayed on the LED. 

    Image Added

    Info

    The program # is displayed on the right.

     

     

  12. Push the green start button. 

    Info

    At any moment if any issue to terminate push the RED button



  13. To repeat : 
    1. switch to Teaching mode in the Changing Mode window from the Robot menu. 
    2. made the proper changes to the program 
    3. restart from #9 


...