Advanced Tables - Table Plus |
---|
border | 0 |
---|
columnTypes | S,F,F,F |
---|
columnAttributes | font-size:12pt; text-align: center;" |
---|
align | center |
---|
title | 'Example Device Types' |
---|
align | center |
---|
highlightColor | white |
---|
sortColumn | 1 |
---|
bgcolor | silver |
---|
cellpadding | 10 |
---|
cellspacing | 0 |
---|
class | '' |
---|
sortIcon | true |
---|
|
Device Type | Nodename | Comment |
---|
Access Switch | ACSW-IN20-NW01 | | Terminal Server | TS-IN20-NW01 | | Scope | SCOP-IN20-NW01 | LCLS Injector Scope | Scope | SCOP-SYS0-NW01 | LCLS Roaming Scope | Magnet IOC | IOC-IN20-MG01 | Magnet injector ioc | Magnet IOC 2nd NIC | IOC-IN20-MG01-FNET | Magnet injector ioc feedback |
|
To obtain an ip address for an LCLS device click here for SCCS IP/Node Name Request form. Fill out this form according the the naming conventions described herein and email this information to Charlie Granieri.
The Device Type Field
Wiki Markup |
---|
{center}{*}Table 1.0{*}{center} |
Advanced Tables - Table Plus |
---|
border | 0 |
---|
columnTypes | S,F,F,F |
---|
columnAttributes | font-size:12pt; text-align: center;" |
---|
align | center |
---|
title | 'Device Types Field' | align | center |
---|
highlightColor | white |
---|
sortColumn | 1 |
---|
bgcolor | silver |
---|
cellpadding | 10 |
---|
cellspacing | 0 |
---|
class | '' |
---|
sortIcon | true |
---|
|
Device Type | Description | Manufacturer | Model |
---|
ACSW | AC Switch | | | CHAS | Chassis | | | GPIB | GPIB/LAN Gateway | | | DDM | Digital Multimeter | Keithley | 2701 | RTR | Router | Cisco | | SWH | Ethernet Switch | CISCO | | SCOP | Scope | Tektronix | DPO4054BDPO4054B | TS | Terminal Server | DIGI | DIGI-TS16 | UPS | Uninterruptible Power Supply | APS | | WKUP | Walk-up ethernet connection | | | EIOC | Embedded IOC | NetBurner,Arcturus | Coldfire 5282, MicroC5282 | IOC | IOC | Motorola | MVME6100, MVME3100 | SIOC | Soft IOC | Linux Host | | VIOC | Virtual IOC (Process) | | | CPU | Central Processing Unit | COMx,etc | | PLC | Programmable Logic Controller | Allen-Bradley,Pils | | PNA | Phase Noise Analyzer | Holzworth | HA7062C | PSC | Ethernet Power Supply Controller | SLAC (Dave MacNair) | EPSC | CAMR | Camera for Beam Line Optics | Pulnix | | CRAT | Intelligent VME Crates | Wiener/Dawn | | MET | Metrology | | | INST | Instrument | | |
|
...
The Area field is 4 characters in length. There are currently 24 areas in the LCLS Accelerator. Going from the Drive Laser to the Experimental areas they include:
Wiki Markup |
---|
{center}{*}Table 1.1{*}{center} |
Advanced Tables - Table Plus |
---|
border | 0 |
---|
columnTypes | S,F,F,F |
---|
columnAttributes | font-size:12pt; text-align: center;" |
---|
align | center |
---|
title | 'Area Field' | align | center |
---|
highlightColor | white |
---|
sortColumn | 1 |
---|
bgcolor | silver |
---|
cellpadding | 10 |
---|
cellspacing | 0 |
---|
class | '' |
---|
sortIcon | true |
---|
|
Area | Physical Location |
---|
ACR0 | Accelerator Control Room (B052) | AS01 | Accelerator Structure Test System(ASTA) | LI00 | LINAC Sector 0 | LR20 | Laser Room (Upstairs, near sector 20) | LA20 | FACET Laser Room (Upstairs, near Sector 20) | IN20 | Injector | LI20 | LINAC Sector 20 | LI21 | LINAC Sector 21 | LI22 | LINAC Sector 22 | LI23 | LINAC Sector 23 | LI24 | LINAC Sector 24 | LI25 | LINAC Sector 25 | LI26 | LINAC Sector 26 | LI27 | LINAC Sector 27 | LI28 | LINAC Sector 28 | LI29 | LINAC Sector 29 | LI30 | LINAC Sector 30 | MCC0 | Main Control Center (B005) OBSOLETE. Replaced by ACR0 | B005 | Access Building 5 | B052 | Access Building 52 | B136 | Access Building 136 | B911 | Access Building 911 | B912 | Access Building 912 | B913 | Access Building 913 | B921 | Access Building 921 | BSY0 | Beam Switchyard | BSYS | Beam Switch Yard South | BSYN | Beam Switch Yard North | BSYA | Beam Switch Yart A-Line | ESA0 | End Station A and Beam Dump East | BSYB | Beam Switchyard B-Line | LTU0 | LINAC-to Undulator Switchyard | LTU1 | LINAC-to-Undulator Line 1 | UND1 | Undulator on Line 1 | DMP1 | Beam Dump on Line 1 | FEE1 | Front End Enclosure on Line 1 | NEH1 | Near Experimental Hall on Line 1 | XRT1 | X-Ray Tunnel on Line 1 | FEH1 | Far Experimental Hall on Line 1 | SYS0 | LCLS System | SYS1 | FACET System | SYS2 | LCLS-II System | SYS3 | LCLS-III System | SYS4 | NLCTA System | SYS5 | SPEAR System | SYS6 | X-Band Test Area System | SYS7 | ASTA System | SYSW | Global System West | SYSE | Global System East | GBL0 | Global to all Machines | AS01 | ASTA | XT01 | X-Band Test Area |
|
...
The Position Field - Subsystem Prefix
Wiki Markup |
---|
{center}{*}Table 1.2{*}{center} |
Advanced Tables - Table Plus |
---|
border | 0 |
---|
columnTypes | S,F,F,F |
---|
columnAttributes | font-size:12pt; text-align: center;" |
---|
align | center |
---|
title | 'Subsystem Prefix Field' | align | center |
---|
highlightColor | white |
---|
sortColumn | 1 |
---|
bgcolor | silver |
---|
cellpadding | 10 |
---|
cellspacing | 0 |
---|
class | '' |
---|
sortIcon | true |
---|
|
Subsystem Prefix | Subsystem |
---|
LS | Laser Steering | PM | Profile Monitor | SP | Spectrometer | IM | Current Monitor | BL | Bunch Length Monitor | BP | Beam Position Monitor | MC | Motion Control | CL | Collimator | AM | Alignment Mirror | AL | Alarm Handler | LG | Data Logger | MG | Magnet | EV | Event | RF | Low-Level RF (LLRF) | KY | Klystron | MP | Machine Protection System (MPS) | NW | Network Device, terminal servers, switches routers, scopes, UPS, etc. | PP | Personnel Protection System (PPS) | BC | Beam Containment System (BCS) | TM | Temperature Monitor | TR | Toroid | VA | Vacuum | WS | Wire Scanner | FB | Beam-based Feedback |
|
...