To explore the ring map in interactive mode, use the buttons on within the bottom right of the Gliffy diagram macro . They work inline on Chrome; on Safari, you in the table on the left. You may need to enter full screen. Hover your mouse over the image to get the full screen menu option. Please note that the CMM measurements seem to take an especially long time to display.
Gliffy Diagram | |||||||
---|---|---|---|---|---|---|---|
|
Screenshots from the Loading layers of the Interactive Map
Observations, properties, and measurements by Heater ID
Properties
Quads
Heater ID: Quads, batch | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 | Uncertainty | Source |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Length (cm) | 4.110 | 4.106 | 4.102 | 4.101 | 4.105 | 4.101 | 4.101 | 4.108 | 4.105 | 4.103 | ±30 μm | Heaters.xlsx |
Width (cm) | 4.254 | 4.245 | 4.244 | 4.246 | 4.253 | 4.254 | 4.264 | 4.254 | 4.255 | 4.247 | ±30 μm | Heaters.xlsx |
Thickness (μm) | 310 | 310 | 315 | 312 | 312 | 315 | 312 | 312 | 312 | 312 | ±5 μm | Heaters.xlsx |
Resistance when wires first bonded (Ω) | 2.4 | 2.4 | 2.4 | 2.6 | 2.4 | 2.5 | 2.5 | 2.3 | 2.4 | 2.4 | ±0.1 Ω | Heaters.xlsx |
Resistance: mounted on ring, before spray painting (Ω) | 2-3 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | Heaters.xlsx | |
Mass (g) | 1.498 | 1.564 | ± 0.001 g | |||||||||
Module thickness at center, measured with micrometers (μm) | 305 | 303 | ± 1 μm | |||||||||
Wire thicknesses, measured with calipers (mm) |
Triplets
Heater ID: Singles, batch | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #18 | #9 | Uncertainty | Source |
---|---|---|---|---|---|---|---|---|---|---|---|
Length (cm) | ±30 μm | Heaters.xlsx | |||||||||
Width (cm) | ±30 μm | Heaters.xlsx | |||||||||
Thickness (μm) | ±5 μm | Heaters.xlsx | |||||||||
Resistance when wires first bonded (Ω) | 2.4 | 2.4 | ±0.1 Ω | Heaters.xlsx | |||||||
Resistance: mounted on ring, before spray painting (Ω) | 2-3 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | Heaters.xlsx | |
Mass (g) | ± 0.001 g | ||||||||||
Module thickness at center, measured with micrometers (μm) | ± 1 μm | ||||||||||
Wire thicknesses, measured with calipers () |
Heater visual inspection
Quads
Heater ID | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 |
---|---|---|---|---|---|---|---|---|---|---|
Before IPA wash & dry rag polish | ||||||||||
After IPA wash & dry rag polish | ||||||||||
Comments | Particles across its surface. Nico tried to blow them off with an ion gun. No effect | Noticed a peculiar speck artifact. Did not come off with a single IPA cleaning. Appears to be Cu |
Triplets
Heater ID | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #18 | #9 |
---|---|---|---|---|---|---|---|---|---|
Before IPA wash & dry rag polish | |||||||||
After IPA wash & dry rag polish | |||||||||
Comments |
Loading experience
Quads
Heater ID | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #8 | #9 | #10 |
---|---|---|---|---|---|---|---|---|---|---|
Load date | 2021-05-03 | 2021-05-03 | ||||||||
Load position | Q9 | Q10 | ||||||||
Shim testing results | ||||||||||
Expected glue layer thickness (μm) | ~200 | 100-200 | ||||||||
100-μm shim | Pass | Pass | ||||||||
200-μm shim | Fail | Pass | ||||||||
Glue batch | ||||||||||
Syringe ID | 2021-A-14 | 2021-A-14 | 2021-A-14 | 2021-A-14 | 2021-A-15 | 2021-A-15 | 2021-A-15 | 2021-A-15 | 2021-A-12 | 2021-A-12 |
Dispensing | ||||||||||
Estimated glue mass per star (mg) | 71 | 71 | ||||||||
Averaged mass tests | 2, 3, 4, 5 | 2, 3, 4, 5 | ||||||||
Time elapsed since syringe fully thawed | 64 | 64 | ||||||||
Minutes module held under vacuum (Hold time) | Overnight | Overnight |
Triplets
Heater ID | #1 | #2 | #3 | #4 | #5 | #6 | #7 | #18 | #9 |
---|---|---|---|---|---|---|---|---|---|
Load date | |||||||||
Load position | |||||||||
Shim testing results | |||||||||
Expected glue layer thickness (μm) | |||||||||
100-μm shim | |||||||||
200-μm shim | |||||||||
Glue batch | |||||||||
Syringe ID | |||||||||
Date dispensed | |||||||||
Dispensing | |||||||||
Estimated glue mass per star (mg) | |||||||||
Averaged mass tests | |||||||||
Time elapsed since syringe fully thawed | |||||||||
Minutes module held under vacuum (Hold time) |
Metrology