The idea is to put scripts under scripts and scan or lowFlux ntuples/.npy files etc under scan or lowFlux. This is how I had things set up on the old psana.
To copy the files to another experiment (from mfxx1005021 to xcsc00120), then use:
cp -rp /sdf/data/lcls/ds/mfx/mfxx1005021/results/scripts /sdf/data/lcls/ds/xcs/xcsc00121/results/scripts
cp -rp /sdf/data/lcls/ds/mfx/mfxx1005021/results/scripts /sdf/data/lcls/ds/xcs/xcsc00121/results/scan
cp -rp /sdf/data/lcls/ds/mfx/mfxx1005021/results/scripts /sdf/data/lcls/ds/xcs/xcsc00121/results/lowFlux
however, you will lijkely not want to copy all the files in scan and lowFlux, so it might be easier to just create them in the folder for the new experiment.
Instructions to run the DAQ scripts and analysis:
...
Attenuator scans:
DAQ scans:
- intensity scan that produces multiple files:
Leland has written a new attenuator scan script for us. To use this, go on mfx-daq and:
...
The DAQ needs to be in the configured state before running this script.
2. intensity scan that produces a single file:
x.attenuator_single_scan(events=12000,record=True,transmissions=[1.0,0.8, 0.61,0.4,0.2,0.1,0.05,0.01])
1.0,0.8, 0.61,0.4,0.2,0.1,0.05,0.01 are the transmissions with 1.0 having no attenuation, and 0.01 being 1% transmission.
Analysis script:
??????
Timing scans:
...
Updated default run for intensity scans:
Results:
Link to analysis plan:
Beamtime run notes (Bhavna):
https://docs.google.com/document/d/1eYhR0q_LjSd4DGc9OnYuBl2aFFucNxmGOBq_E0NMT5g/edit
Analysis plan (Bhavna):
https://docs.google.com/spreadsheets/d/10m2vQLeCrlIA53khhRLaTRqm4YGobh0RGqGaE3A_WL8/edit
Primary finding for smalls: the detector is marginally timed in, which is causing the low values after switching. The delay, ACQToAsicR0delay, should be shifted from 18223 to 17223.
Google Drive folder for presentations with results etc.:
https://drive.google.com/drive/u/1/folders/1oolbkUqPAMD76qWZYiGQvVKIQPCqUfBS
Initial simulations of effects for getting the timing wrong. (Conny)
View file | ||||
---|---|---|---|---|
|
Overview of initial findings. (Conny)
View file | ||||
---|---|---|---|---|
|
Register settings for the various cameras for easy access. (Conny)
View file | ||||
---|---|---|---|---|
|
Small study of the double population. (Xavier)
View file | ||||
---|---|---|---|---|
|
Timing in an ePix detector with LCLS timing system - VB (Dionisio)
View file | ||||
---|---|---|---|---|
|
Double population (Xavier)
View file | ||||
---|---|---|---|---|
|