The beampipe consists of a cylindrical central tube and forward/backward conical sections.  The 0.040cm thick Beryllium central tube has an inner radius of 1.2cm and extends to |z|<6.25cm. The conical sections have a cone half-angle of 43.4mrad with an inner radius that flares from 1.2 cm at 6.25cm to 8.218cm at |z|=167.9cm. The conical sections are 0.0875Cm thick Be for 6.25cm<|z|<37.5cm, where they transition to steel. The thickness of the steel section flares from 0.0875cm at |z|=37.5cm to 0.1992cm at |z|=167.9cm. A titanium inner liner on the inner surface of the beam pipe consists of a 0.0025cm thick cylinder and 0.0075cm thick conical sections.

...

The entire vertex detector is enclosed within a double walled carbon fiber support tube. The support tube walls are 0.05cm thick carbon fiber with inner radii of 16.87cm and 18.42cm and a |z| extant of |z|<89.48cm. The ends of the support tube double-walled disks of 0.05cm thick carbon fiber disks that span 5.5cm<r<16.87cm and are located at |z|=97.5cm and |z|=99.74cm.disks located as follows:

Wall

Inner Radius

Outer Radius

Inner |z|

Inner

4.80cm

16.87cm

86.88cm

Outer

4.91cm

16.87cm

89.43cm

...