Cable batch polarity test

This test was inspired by the incorrect polarity cable that we received in multiple batches. It was type B, while in the second purchase it was a mix of type A and type B. The specs on the order do not say anything. in the next order, we need to explicitly state that we want TYPE A (Straight - Not cross) as we are adopting is a standard for couple configuration in the detector.

...

Results of testing all cables are as follows

NumberType
3701

A

3696A
3697B
3700B
3698B
3699A
3705B
First batch cableB