Muon System:
...
Air
...
The muon system is implemented as a sampling calorimeter composed of 11 layers of :
...
material
...
thickness
...
Iron
...
20.0cm
...
G10
...
0.3cm
...
PyrexGlass
...
0.11cm
...
RPCGas
...
0.12cm
...
PyrexGlass
...
0.11cm
20cm thick Iron plates interspersed with double RPC readout.
The barrel inner radius is 338.8cm with z extent of +/- 294cm.
The endcap sits outside the barrel at an inner z of 303.3cm and radius from 20.0cm to 608.2cm
...