Tolerance Item | Where Used | Tolerance (mm, Dia.) |
Pick-up Table Edge Repeatability (repeatability of lining up module to machined edges) | Locating Module to Pickup Table | .002000 |
Bridge Bushing ID | Locating Loading Bridge to Pick-up Table | .012 |
Pick-up Table Pin OD | Locating Loading Bridge to Pick-up Table | .012 |
Pin Location | Locating Loading Bridge to Pick-up Table | .025 |
Bridge Bushing ID | Locating Loading Bridge to Loading Fixture | .012 |
Baseplate Pin OD | Locating Loading Bridge to Loading Fixture | .012 |
Pin Location | Locating Loading Bridge to Loading Fixture | .025 |
Total: | .100mm 98mm (+/-.050mm) | |
Root Sum Square: | .043mm (+/-.019mm) |
...
- Total for all:
- Limit: +/-.075mm074mm
- Root sum square: +/-.028mm
...