Turn dry-air valve counterclockwise ¼ turn.
There should be a hissing noise from the air flow.Info This dry air is used to control EFD and height gauge.
Turn EFD on
The screen will display a default menu.
The settings for SE4445 are preset 001and either "steady" or "timed"
Info To change the settings refer to Building 33 - Setting up for gluing in the lab for instructions.
- Turn on glue robot.
The ITkPixel Itk account on the PC has the Janome Points software installed to control the robot.
Info The password is AtlasITkBox. For info about the itk-admin account contact Matthias Wittgen
- Click on the desktop icon JR C-Points to start the program
- Select If a window is shown - please select the following options to initialize the program :
- JR2500-N bullet
- z-axis control
- R-axis control (not ticked!)
- IO-A (not ticked)
See picture for comparison:
Open the point program file
Neha_2020Feb3_InnerRingx3.cpd
it should be the most recent file select the program #Info The program # is displayed on the right.
We are using the program #13 for the triplet in a row.
Note that the pallet routine is #22 (plane, with auto-increment)
Initialize the robot with
Meca Initialize
:
Info Verify that the z position is placed correctly by using the Tool option to verify the PTP point – hit Go and don't hit Register until you are sure about you want to update the xyz position.
To execute the program hit
Send C&T data
from the Robot menu.Info Make sure that the Robot is set in
Teaching mode
in theChanging Mode
window from the Robot menu.Select Switch Run Mode in the
Changing Mode
window from the Robot menu.Select the program # to execute from the Robot command buttons. It will be displayed on the LED.
Info The program # is displayed on the right.
Make sure to use the same # selected in point 7.Push the green start button.
Info At any moment if any issue to terminate push the RED button
- To repeat :
- switch to
Teaching mode
in theChanging Mode
window from the Robot menu. - made the proper changes to the program
- restart from #9 #9
- switch to
- To terminate - before you leave the station:
- Bring the robot back in the original position with
Meca Initialize
- Shut down the robot
- Shut down the EFT
- Turn off the valve
- Terminate the program
- Shut down the screen only of the PC
- Bring the robot back in the original position with
Related articles