Test on Bare Local Support with active cooling system (July 8th 2020): 

PictureDescription
Local Support at the start of the cooling process

Local Support at the start of the cooling process (2:43 pm, 7/8/20).

The minimum temperature read in the local support is about -3 ºC.

To understand the structure, please compare the IR camera picture with the picture below from the visible light camera.

 

Image Added

Detail of the handling frameDetail of the handling frame.
Local Support after about half an hour of cooling on

Local Support after about half an hour of cooling on (3:24 pm, 7/8/20).

The minimum temperature read in the local support now is about -40 ºC.

View file
namethermalVideo_1594244631623.mp4
height250
Video of the IR camera view while moving it with the Gantry system

...