PV Name | Type | Description |
---|
$(DEV):VERSION | stringin | DOSFET controller version |
$(DEV):ID | stringin | DOSFET serial number |
$(DEV):GET_DELAY | ai | Readback of pause between applying readback current and reading voltage |
$(DEV):SET_DELAY | ao | Set pause time between applying readback current and reading voltage |
$(DEV):GET_BIAS | ai | Readback bias voltage used between dose readings |
$(DEV):SET_BIAS | ao | Set bias voltage used between dose readings |
$(DEV):SAVE_SETTINGS | bo | Save delay and bias settings in the chassis non-volatile storage. |
$(DEV):SET_PERIOD | ao | Dose readback sampling interval setting |
$(DEV):BOARD_TEMP | ai | DOSFET chassis main board temperature |
$(DEV):POLL_ENABLE | bo | Enable/disable dose readback polling. |
$(DEV):POLL_DELAY | ao | Dose readback sampling interval readback |
$(DEV):GATE_POLLING | ai | Counter for seconds since the last dose readback cycle |
...
DOSFET locations and sensor to chassis mapping
DOSFET controller rack/ nearest undulator cell location | Network host name | MAC address | Controller connection | Sensor undulator # | Sensor apx. z-location (ft) | Device PV "Location" field $DEV |
---|
HXUC-2/HXU14 | radm-undh-rm01 | 00:80:A3:9B:A9:34
| A | HXU13 | 11702 | RADM:UNDH:1377: |
B | HXU14 | 11716 | RADM:UNDH:1477: |
C | HXU15 | 11728 | RADM:UNDH:1577: |
D | HXU16 | 11742 | RADM:UNDH:1677: |
HXUC-6/HXU18 | radm-undh-rm02 | 00:80:A3:A1:81:05
| A | HXU17 | 11755 | RADM:UNDH:1777: |
B | HXU18 | 11768 | RADM:UNDH:1877: |
C | HXU19 | 11781 | RADM:UNDH:1977: |
D | HXU20 | 11795 | RADM:UNDH:2077: |
HXUC-10/HXU22 | radm-undh-rm03 | 00:80:A3:9B:A9:1F | A | Self Seeding | 11808 | RADM:UNDH:2177: |
B | HXU22 | 11820 | RADM:UNDH:2277: |
C | HXU23 | 11833 | RADM:UNDH:2377: |
D | HXU24 | 11846 | RADM:UNDH:2477: |
HXUC-14/HXU26 | radm-undh-rm04 | 00:80:A3:A1:81:11 | A | HXU25 | 11860 | RADM:UNDH:2577: |
B | HXU26 | 11873 | RADM:UNDH:2677: |
C | HXU27 | 11887 | RADM:UNDH:2777: |
D | Self Seeding | 11900 | RADM:UNDH:2877: |
HXUC-18/HXU30 | radm-undh-rm05 | 00:80:A3:A1:81:1B
| A | HXU29 | 11913 | RADM:UNDH:2977: |
B | HXU30 | 11932 | RADM:UNDH:3077: |
C | HXU31 | 11932 | RADM:UNDH:3177: |
D | HXU32 | 11932 | RADM:UNDH:3277: |
HXUC-22/HXU34 | radm-undh-rm06 | 00:80:A3:A1:81:OE | A | HXU33 | 11932 | RADM:UNDH:3377: |
B | HXU34 | 11932 | RADM:UNDH:3477: |
C | HXU35 | 11952 | RADM:UNDH:3577: |
D | HXU36 | 11965 | RADM:UNDH:3677: |
HXUC-26/HXU38 | radm-undh-rm07 | 00:80:A3:A1:81:17
| A | HXU37 | 11978 | RADM:UNDH:3777: |
B | HXU38 | 11991 | RADM:UNDH:3877: |
C | HXU39 | 12005 | RADM:UNDH:3977: |
D | HXU40 | 12018 | RADM:UNDH:4077: |
HXUC-30/HXU42 | radm-undh-rm08 | 00:80:A3:9B:A9:10 | A | HXU41 | 12031 | RADM:UNDH:4177: |
B | HXU42 | 12044 | RADM:UNDH:4277: |
C | HXU43 | 12058 | RADM:UNDH:4377: |
D | HXU44 | 12071 | RADM:UNDH:4477: |
HXUC-34/HXU46 | radm-undh-rm09 | 00:80:A3:9B:A9:26 | A | HXU45 | 12084 | RADM:UNDH:4577: |
B | HXU46 | 12097 | RADM:UNDH:4677: |
...
INTERNAL ONLY name mapping for maintenance reference
...
.
NOT PART OF THE NAMING CONVENTION
NOT APPEARING ON ANY SCREENS
In this table, the "PV Name" column defines the user/programming interface with DEV defined by sensor location, e.g. DEV=RADM:GUNB:621: for a sensor at location 621 in GUNB, and "Wrapped internal name" is the names used internally, for which "PV Name" is a wrapper (not exposed on screens) which reflect the chassis channel labeling and manufacturer's documentation, e.g. P=RADM:GUNB:201RM01: and SENSOR=B for channel B of the second chassis at location 201 in GUNB. . SENSOR on the chassis side is A, B, C, or D.
PV Name | Wrapped internal name | Description |
---|
$(DEV):1:RAW | $(P):$(SENSOR)1:RAW | Raw voltage readback. Channel 1 of RadFET pair. |
$(DEV):1:ZERO_VOLTS | $(P):$(SENSOR)1:ZERO_VOLTS | Raw voltage at 0 accumulated dose. Channel 1 of RadFET pair. |
$(DEV):1:DELTA_VOLTS | $(P):$(SENSOR)1:DELTA_VOLTS | Raw voltage difference, from 0 to now. Channel 1 of RadFET pair. |
$(DEV):1:DOSE | $(P):$(SENSOR)1:DOSE | Accumulated dose. Channel 1 of RadFET pair. Calculated from DELTA_VOLTS, with an equation configured by radiation physicists |
$(DEV):1:RAW_STATUS | $(P):$(SENSOR)1:RAW_STATUS | Sensor status. Channel 1 of RadFET pair. |
$(DEV):2:RAW | $(P):$(SENSOR)2:RAW | Raw voltage readback. Channel 2 of RadFET pair. |
$(DEV):2:ZERO_VOLTS | $(P):$(SENSOR)2:ZERO_VOLTS | Raw voltage at 0 accumulated dose. Channel 2 of RadFET pair. |
$(DEV):2:DELTA_VOLTS | $(P):$(SENSOR)2:DELTA_VOLTS | Raw voltage difference, from 0 to now. Channel 2 of RadFET pair. |
$(DEV):2:DOSE | $(P):$(SENSOR)2:DOSE | Accumulated dose. Channel 2 of RadFET pair. |
$(DEV):2:RAW_STATUS | $(P):$(SENSOR)2:RAW_STATUS | Sensor status. Channel 2 of RadFET pair. |
$(DEV):TEMP | $(P):[A,B,C,D]$(SENSOR)TEMP | Temperature of the sensor board. |
...