- Start chiller: 18 Celsius
- Switch on power supply: 8V constant --> check 2.0 A
- Switch on NI crate and TLU
1. Start sensors
- Remote access to NI crate:
-- Open Terminal
-- source access_NI_crate.sh
-- Login: telescope PWD: telescope+
- Start MI26.exe (upper icon on the NI crate Desktop)
-- Open .mcf threshold file, typically 6 (CALADIUM config files are in C:\opt\mimosas\config_files)
-- Press "Reset" --> 2.0 Amps
-- Press "All" --> 2.8 Amps
-- Press "Read" --> 2.8 Amps
-- Press "Start" --> check 3.6 Amps
2. Open Labview FPGA interface on NI crate, if not already open
- Double click MimosaDAQ (second upper icon on the Desktop)
3. Start EUDAQ on AR-EUDAQ:
- Open a second Terminal
- cd /opt/install/eudaq/eudaq-1.7 (need to make a shortcut -BPN 6/1/2018)
- source setup_eudaq.sh
- ./STARTRUN
- wait approx. 20 sec. until all Connections ping (unitialized)
4. Open TLUproducer on TLUproducer computer. N.B. this is currently the YARR computer but we need to change this when the YARR folks are not at SLAC! (-BPN 6/1/2018)

...