Name | Description |
---|
GDES | Operation Gradient setpoint (MV/m) |
GACT | Measured gradient from cavity probe (MV/m) |
GMAX | Maximum allowable gradient (MV/m) |
GCAL | Gradient calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output. |
ADES | Operation Amplitude setpoint (MV) |
AACT | Measured amplitude from cavity probe (MV) |
AMAX | Maximum allowable amplitude (MV) |
ACAL | Amplitude calibration scale factor, nominally 1. Multiply by this when calculating raw register value to set, so increasing GCAL increases output. |
PDES | Operation Phase setpoint (degrees, where 0 is on-crest) |
PACT | Measured phase from cavity probe (degrees) |
PREF | a.k.a.gold, phase offset used by LLRF to convert measured phase to one relative to on-crest operation, adjusted by beam phasing (detrees) |
PMAX? | Could be included, staying parallel to GMAX, but is this useful? |
PCON | See GCON above |
FDES | Cavity detuning setpoint (Hz) |
FACT | Detune seen by the resonance system (Hz) | FCON | See GCON above |
Mode | RF mode (off, pulsed, SEL, GDR) |
RFCTRL | Master enable for an RF cavity (On, Off) \[How to distinguish this from the SSA specific RF enable register?] |
RFReady | Status of RF controls, (Ready, Not Ready) set to ready when control loops are closed and RF is continuous. Or will we ever run with pulsed RF? |
Quench | Status showing when a cavity quenches, from interlocks (Normal, Quenched) |
STAT | Status bits in software (define the bits) |
HSTA | Hardware status |
GTRACE | Gradient | Gact[TBD] | Amplitude waveform from the cavity probe, which is used to calculate GACT (MV/m) |
PactWFPTRACE | Phase waveform from the cavity probe, which is used to calculate PACT (degrees) |
GfwdWFGFWDTRACE | Amplitude Gradient waveform from SSA output (MV/m) |
PfwdWFPFWDTRACE | Phase waveform from SSA output (degrees) |
GrevWFGREVTRACE | Reverse/reflected SSA output amplitude gradient waveform (MV/m) I'm favoring rev over ref because ref sounds to me like "reference" |
PrevWFPREVTRACE | Reverse/reflected SSA output phase waveform (degrees) |
*ErrWFERRTRACE | Error waveforms corresponding to waveforms above, captured and put in a separate buffer when a fault is detected (degrees or MV/m) |
| Any of the above in I/Q equivalent of Amplitude/Phase |
PwrFwd | Forward power from SSA to cavity |
PwrRev | Reflected/reverse power from cavity |
PzWF | Waveforms from tuner piezo motors, useful for finding microphonics. Units TBD. |
ALEM | LEM computed integrated RF amplitude (MV) per cavity and per cryomodule |
PLEM | LEM computed phase (deg) |
EGLEM | LEM computed energy gain (MeV) |
CHLEM | LEM computed chirp (MeV) |