Pulse Selector in the Hutches
Wednsday Jul 3rd
SOLVED:
- Integrate 4 shots instead of 3 (using ccdtake(3, 1 , bShutter=True)
- missing some shots when in 2 shots mode. SOLVED (USING MODE 3.2)
- Switch from mode anymode to anymode OK
IMPROVED:
- PV's for OPEN and CLOSE range check
- Pre-mode alignment subroutine.
TODO:
- Fast OPEN and CLOSE
- RESET_PG Flag as PV (to monitor the finish reset process)
- ALIGN Flag as PV (monitor the pre-mode alignment feature)
Tuesday Jul 2nd
Initial XRay aligned positions:
Y position: 0.0000 mm
X position: 0.1512 mm
...