Server/ Service

Description

Location

SCADA

Enclave

I = In

Blank = out

Observing Continuity Critical

I = In

Blank = out

S = straddle

Sizing

Special Power Needs

Communications In (data rate)

Communications Out (data rate)

Network Interface Bandwidth

(1 Gb,

10 Gb)

Appears on Backbones

Does (any) data in "Comm's out" go to EFD?

Name on Backbone Diagrams

Notes, Aliases

Master Control Module

Master control module coordinates delegation of observatory commands to camera subsystems

Summit Computer Room

 

I

1U

 

 

 

1Gb

Camera Control

No

CCS

 

Camera Database

Camera trending and configuration database

Summit Computer Room

 

I

2U

 

 

 

1Gb

Camera Control

No

CCS

 

Camera Database Backup

Backup (mirror) of camera database at base

Base Data Center

 

 

2U

 

 

 

1Gb

Camera Control

No

Camera IT HW

 

Lock Manager

Lock manager coordinates interlocks between camera consoles and OCS

Summit Computer Room

 

I

1U

 

 

 

1Gb

Camera Control

No

CCS

 

Rafts Control HCU

Hardware control unit for DAQ/focal plane

Summit Computer Room

 

I

1U

 

 

 

1Gb

Camera Control

No

CCS

 

Camera HCUs

Hardware control units (7) inside utility trunk or on camera body that control camera subsystems.

We need to clarify how the connection between the utility trunk and the camera control backbone (via the CCS fiber is made)

Inside Camera utility trunk or Camera body

 

I

~7 embedded (PC104) computers

 

 

 

n/a

Camera Control

No

CCS

 

Camera Router

Router to provide connectivity to Camera HCUs

Inside Camera utility trunk

I

 

Small (~1u)

 

 

 

n/a

Camera Control

No

CCS

 

Refrigerator Compressor Controller

Refrigerator compressor cabinets that are on the telescope are on the general network.

See LSE-64 CA-TS-UTI-ICD-0050

On the telescope mount

 

I

1U (HCU)

1 console (laptop)

 

 

 

1Gb

Camera Control

No

Refrigerator Compressor Controller

 

Camera Maintenance Laptop

Laptop used for camera maintenance

See LSE-64 CA-TS-UTI-ICD-0022

Service platform used to access camera utility trunk

 

 

1 console (laptop)

 

 

 

1Gb

Camera Control

No

NA

 

Diagnostic Cluster

Diagnostic cluster is used for camera image diagnostics and for feeding images to camera visualization server,

Summit Computer Room

 

I

10x1U

 

Images

Telemetry

10x10Gb

Camera Control, Camera Data

Yes

Diagnostic Cluster

 

Visualization server

Visualization server backend (firefly)

Summit Computer Room

 

I

1U

 

Images and metadata

Displays (40 Gbps)

4x10Gb

Camera Control

No

Camera Visualization Server and Display

Includes Firefly Server

CCS-OCS bridge

Relays Commands and Telemetry between CCS and OCS

Summit Computer Room

 

I

1U

 

Commands and Telemetry

Commands and Telemetry

1Gb

Camera Control, Telescope Control

Yes

OCS Bridge

 

Read-out System

Reads out sensor data

Summit Computer Room

 

I

Part of 14U for entire DAQ

 

Sensor read-outs

Images

 

Camera Data

No

Read-Out System

Connected directly inside Camera, writes to Image Data Store

DAQ Management Server

Installs software, runs DHCP for DAQ, runs initialization

Summit Computer Room

 

I

1U

 

 

Software installs/configuration instructions, DHCP assignments

1Gb

Camera Control, Camera Data

No

DAQ Management Server

 

Camera Devices connected by Private Network

Sensors and Power Supplies

Inside Camera

I

I

(Not in racks)

 

 

 

 

Camera Internal Network

No

 

 

Connected via CCS fiber to utility trunk

Camera Annex CCS

Camera Control in the Annex

Camera Annex

 

 

 

 

 

 

 

Camera Support Rooms

 

Camera Annex CCS

 

Clean Room CCS

Camera Control in the Clean Room

See LSE-65 CA-TS-FAC-ICD-0035

Clean Room

 

 

 

 

 

Simulated images and telemetry

 

Camera Support Rooms

Yes

Clean Room CCS

Additional camera discussions are needed to clarify network drops needed in camera test/maintenance area

White Room CCS

Camera Control in the White Room

See LSE-65 CA-TS-FAC-ICD-0026

White Room

 

 

 

 

 

 

 

Camera Support Rooms

 

White Room CCS

 

Support Room DAQ

Data Access for when Camera is in Staging Area

TBD (Staging area?)

 

 

 

 

 

 

 

Camera Support Rooms

 

Support Room DAQ

 

Refrigerator maintenance Compressor Controller

Refrigerator compressor cabinets that are on the network drop on service platform on the CCSnetwork in the machine room

See LSE-65 CA-TS-FAC-ICD-0045 (question)

In the machine room below the staging area

 

 

1U (HCU)

1 console (laptop)

 

 

 

 

Camera Support Rooms

 

Refrigerator Compressor Controller

 

These are additional compressors used when the camera is in the staging area. They are located in a machine room below the staging area.

Visualization client

Displays visualization content

Control room annex(?)

 

I

(Not in racks) Desktop

 

 

 

10Gb

Camera Control

 

 

 

Consoles

Operator interfaces

Control room annex

 

I

3 consoles

 

 

 

1Gb

(10Gb if need to display visualization)

Camera Control

No

 

 

Console at baseOperation interfaces at baseBase control room  3 consoles   1GbCamera ControlNo  
Console at baseOperation interfaces at baseCamera Office at base  3 consoles   1GbCamera ControlNo  