In Development,
- Shelf Manager: shm-b15-rf03-1
- 10G Eth Switch: cswh-b15-rf03-1
- Supervisory Controller CPU: cpu-b15-rf03
- IOCs:
- sioc-b15-rf11 ==> SLOT 2 ==> XTCAV NC HXR & SXR LLRF Controller (LCLS-I Timing)
- sioc-b15-rf12 ==> SLOT 3 ==> XTCAV NC HXR & SXR LLRF Diagnostics (LCLS-I Timing)
- sioc-b15-rf21 ==> SLOT 5 ==> XTCAV SC HXR & SXR LLRF Controller (LCLS-II Timing)
- sioc-b15-rf22 ==> SLOT 6 ==> XTCAV SC HXR & SXR LLRF Diagnostics (LCLS-II Timing)
In Production,
- Shelf Manager: shm-dmp0-rf01-1
- Supervisory Controller CPU: cpu-dmp0-rf01
- IOCs:
- sioc-dmp0-rf11 ==> SLOT 2 ==> XTCAV NC HXR & SXR LLRF Controller (LCLS-I Timing)
- sioc-dmp0-rf12 ==> SLOT 3 ==> XTCAV NC HXR & SXR LLRF Diagnostics (LCLS-I Timing)
- sioc-dmp0-rf21 ==> SLOT 5 ==> XTCAV SC HXR & SXR LLRF Controller (LCLS-II Timing)
- sioc-dmp0-rf22 ==> SLOT 6 ==> XTCAV SC HXR & SXR LLRF Diagnostics (LCLS-II Timing)
In Dev,
$ ssh lcls-dev3
$ ssh cpu-b15-rf03
$ iocConsole.sh sioc-b15-rf11
$ iocConsole.sh sioc-b15-rf12
$ iocConsole.sh sioc-b15-rf21
$ iocConsole.sh sioc-b15-rf22
In Prod,
$ ssh mcclogin
$ ssh softegr@lcls-srv01
$ ssh cpu-dmp0-rf01
$ iocConsole.sh sioc-dmp0-rf11
$ iocConsole.sh sioc-dmp0-rf12
$ iocConsole.sh sioc-dmp0-rf21
$ iocConsole.sh sioc-dmp0-rf22
In Dev,
$ ssh lcls-dev3
$ xtcav-b15.bash
In Prod,
$ ssh mcclogin
$ ssh softegr@lcls-srv01
$ xtcav-llrf-ui.bash
or
$ ssh mcclogin
$ ssh softegr@lcls-srv01
$ lclshome&
When the LCLS home screen appears, click on the DMPH and RF buttons, then click on the ATCA Controls button.