An overall description of the deployed hardware into Production is provided below. The top half describes hardware in Sector-2, while the bottom half presents equipment in Sector-10 (center and right) and Sector-20 (on the left).
(Hardware Deployment - Diagram by Matt Weaver)
Overall, 12 IOCS have been put together to support Linac Locking. The first 6 IOCs --developed a year prior to the current work-- are captured by the diagram below. This first batch of IOCs include controls for the frequency locker, frequency counter, PLL loops and Beckhoff instrumentation.
(Diagram by Kukhee Kim)
The following diagram captures the remaining 6 (most recent) IOCs deployed into Production. This second set of IOCs provides the controls for additional PLLs, re-synchronization triggers, a phase locker, an RFoF system and a trigger alignment/bucket jump detector subsystem.
See below crate & slot information for each of the IOCs.
IOC Name | CPU | Rack | Shelf Manager | IP | Slot |
---|---|---|---|---|---|
sioc-sys0-ms01 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.16 | - | |
sioc-sys0-ms02 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.20 | - | |
sioc-sys0-ms03 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.28 | - | |
sioc-sys0-ms04 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | - | ||
sioc-sys0-ms05 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.19 | - | |
sioc-sys0-ms06 | cpu-sys0-sp01 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.24 | - | |
sioc-sys0-ms07 | cpu-sys0-sp01 | L2KG02-27 | (Uses network switch on shm-sys0-sp01-1) | 192.168.1.17 | - |
sioc-sys0-ms08 | cpu-sys0-sp01 | L2KG02-27 | (Uses network switch on shm-sys0-sp01-1)- | 192.168.1.18 | - |
sioc-sys0-ms09 | L2KG02-24 | shm-sys0-sp01-1 | - | /dev/tpra (PCIe) | |
sioc-sys0-ms10 | cpu-sys0-sp02 | LKG10-27 / LKG10-28 | shm-sys0-sp02-1 | 10.0.1.102 | 2 |
sioc-sys0-ms11 | cpu-sys0-sp02 | L2KG02-27 / LKG10-27 | shm-sys0-sp02-1 | 172.27.136.38 172.27.136.39 | - |
sioc-sys0-ms12 | cpu-li20-ms01 | LKG20-xxx | - | - | /dev/tprb (PCIe) |
The Linac Locking software IOCs are housed by the masterSource repository. In iocBoot/README.linac-locking, a brief description is provided on the role of each of the IOCs.
(base) skoufis@aird-b50-srv01 (master) $ cat iocBoot/README.linac-locking Linac Locking resources in production and development areas are listed below: Production IOCs: sioc-sys0-ms01 ==> SIM16: DAC control for Frequency Locker in L2KG02-25 + Agilent 53220A (Frequency counter) sioc-sys0-ms02 ==> SIM20: MO PLL Control in L2CID-04 sioc-sys0-ms03 ==> SIM28: L2 PLL Control in L2KG04-20 + Beckhoff sioc-sys0-ms04 ==> Beckhoff Only sioc-sys0-ms05 ==> SIM19: VCO DAC control in L2CID-04 sioc-sys0-ms06 ==> SIM24: L2 VCO Control in L2KG04-20 ( sioc-sys0-ms07 ==> SIM17: 11.5MHz PLL control SIM module sioc-sys0-ms08 ==> SIM18: 476MHz PLL control SIM module sioc-sys0-ms09 ==> TPR triggers for ReSynch Chassis sioc-sys0-ms10 ==> phase locker sioc-sys0-ms11 ==> LINAC Locked 476 MHz reference distribution via RF-over-Fiber sioc-sys0-ms12 ==> LINAC Locking Trigger alignment and bucket jump detector Production Hosts: cpu-sys0-sp01 ==> sioc-sys0-ms{01,02,03,04,05,06,07,08} cpu-sys0-sp02 ==> sioc-sys0-ms{10,11} cpu-li20-ms01 ==> sioc-sys0-ms12 Development IOCs: vioc-b084-fl01 ==> SIM21: DAC control for Frequency Locker + Agilent 53220A (Frequency counter) sioc-b084-ms07 ==> SIM17: 11.5MHz PLL control SIM module sioc-b084-ms08 ==> SIM18: 476MHz PLL control SIM module sioc-b084-ms09 ==> TPR triggers for ReSynch Chassis sioc-b084-ms12 ==> LINAC Locking Trigger alignment and bucket jump detector Development Hosts: sioc-b084-sp12 ==> sioc-b084-ms{07,08,09,12}, vioc-b084-fl01