S30XL-LESA/LDMX
It has only two runs 5772: from 0.5mm dataset, and 5611: from 1.5mm data set.
More than 100 files from each run are cooked.
HPS-Java release 4.0
Ingredient | decscription |
---|---|
detector | HPS-EngRun2015-Nominal-v6-0-fieldmap |
fee_steer | /org/hps/steering/production/FEEFilter.lcsim |
fieldmap | 125acm2_3kg_corrected_unfolded_scaled_0.7992.dat |
moller_steer | /org/hps/steering/production/MollerCandidateFilter.lcsim |
p0_steer | /org/hps/steering/production/Pair0TriggerFilter.lcsim |
pulser_steer | /org/hps/steering/production/PulserTriggerFilter.lcsim |
recon_steer | /org/hps/steering/recon/EngineeringRun2015FullRecon.lcsim |
s0_steer | /org/hps/steering/production/Single0TriggerFilter.lcsim |
tuple_steer | /org/hps/steering/analysis/MakeTuplesNoTweak.lcsim |
v0_steer | /org/hps/steering/production/V0CandidateFilter.lcsim |
Out of 242 jobs 6 were timed out "240 194 133 14 18 467".
Reconstruction stops at some point, JVM doesn't exit, doesn't throw exception nor produces any warning message,
it just doesn't reconstruct any more event.
Running it interactively, shows, that lmost 100% of CPU is used by JVM.
Some of input evio files were not properly cached from the tape.
On the cace disk following files have file size=0
Files from 5772: 3 95
files from 5611: 169 205 213
Two plots below show Wall time and CPU time of jobs.
CPU time show quite good mostly below 10 hours.
Quite large number of jobs however have significantly larger wall times.
The reason is not quite clear. Seems Recon is done fine, however it takes quite long time before starting DSTs
/work/hallb/hps/data/engrun2015/tpass7d