Cooling Block | Initial Squareness (<0.050 mm lean at top) | Max Rock (groove/flat - in) | Center Thickness (mm) | Thickness Range (max-min - mm) | Height After Machining at pins (back/front - mm) | Module | Notes |
---|---|---|---|---|---|---|---|
100-1 | Pass | 0.0005 | 5.964 | 0.005 | 52.451/52.451 |
| |
100-2 | Fail - lapped | 0.0005 | 5.972 | 0.008 | 52.451/52.451 | voids in glue? | |
100-3 | Fail - lapped | 0.0005 | 5.997 | 0.013 | 52.451/52.451 |
| |
100-4 | Pass | 0.0005 | 6.022 | 0.003 | 52.451/52.451 |
| |
100-5 | Pass | 0.0005 | 6.015 | 0.005 | 52.451/52.451 |
| |
100-6 | Pass | 0.0005 | 5.961 | 0.008 | 52.451/52.451 | voids in glue? | |
100-7 | Pass | 0.0005 | 5.979 | 0.008 | 52.451/52.451 |
| |
100-8 | Pass | 0.0005 | 5.966 | 0.008 | 52.451/52.451 | voids in glue? | |
100-9 | Pass | 0.0005 | 5.977 | 0.010 | 52.451/52.451 |
| |
100-10 | Pass | 0.0005 | 5.964 | 0.010 | 52.451/52.451 |
|
Cooling Block | Initial Squareness (<0.050 mm lean at top) | Max Rock (groove/flat - in) | Center Thickness (mm) | Thickness Range (max-min - mm) | Height After Machining at pins (back/front - mm) | Module | Notes |
---|---|---|---|---|---|---|---|
50-1 | Fail - lapped | 0.0/0.0 | 5.977 | 0.008 | 50.851/50.851 |
| |
50-2 | Fail - lapped | 0.0/0.0 | 5.984 | 0.010 | 50.851/50.825 |
| |
50-3 | Fail - lapped | 0.0/0.0 | 5.964 | 0.008 | 50.851/50.825 |
| |
50-4 | Pass | 0.0005/0.0005 | 5.974 | 0.010 | 50.825/50.800 |
| |
50-5 | Pass | 0.0005/0.0005 | 5.966 | 0.008 | 50.851/50.825 | voids in glue? | |
50-6 | Pass | 0.001/0.0005 | 5.969 | 0.010 | 50.851/50.825 |
|