Search/Navigation:
Related:
SLAC/EPP/HPS Public
Jefferson Lab/Hall B/HPS Run Wiki
S30XL-LESA/LDMX
Confluence will be down for maintenance June 14 2024 at 6AM PT.
Will start off with full energy electrons (FEE) to set the momentum resolution.
Run the org.hps.analysis.trackingperformance.FeeAnalysisDriver (currently in git issue #309 pending a pull request) over the fee skims to produce the plots.
2015 Data, pass8, Run 5265 (SVT@1.5mm), FEE skims, top and bottom 6-hit tracks.
2015 Data, pass8, Run 5772 (SVT@0.5mm), FEE skims, top and bottom 6-hit tracks.
And, for comparison, 2015 Data, pass4, Run 5772 (SVT@0.5mm), FEE skims, top and bottom 6-hit tracks.
4 Comments
Tim Nelson
Thanks Norman! Clearly does NOT support my impression that resolution has suffered with more alignment work, but 0.5mm/1.5mm comparisons (different only in bottom) are interesting.
Norman Graf
pass4 was actually a pretty good recon.
Tim Nelson
BTW, even if everyone should know them (I don't), could the FEE skim cuts be listed here?
Norman Graf
For this analysis, I start with the FEE skims and apply the following additional cuts: