Half-module #

Contains hybrids

(hole end / slot end)

Contains sensors

(hole end / slot end)

Hybrids glued

Sensors glued

Sent to UCSC

Wirebonded

QA tested

Results

Sent to SLAC

EncapsulatedSylgard Bubbles?Vacuum Tested

Part of module

Notes

L4-L6 Half-Module 0

L4-L6 Hybrid 3 / L4-L6 Hybrid 4 

Sensor 152 / Sensor 648

3/10/2014 (TKN)

3/11/2014 (TKN)

3/12/2014 (TKN/HS)

3/13/2014 (FM)

3/13/2014 (OM)

 

4/4/2014 (PH)

4/8/2014 (TKN)NoN/A

nope

The double-gimp: Since 12/9/14, both HD connectors seem electrically disconnected from hybrids.

L4-L6 Half-Module 01

L4-L6 Hybrid 6 / L4-L6 Hybrid 7 

Sensor 621 / Sensor 622

3/27/2014 (TKN)

3/27/2014 (TKN)

3/30/2014 (PH/VF)

3/31/2014 (FM)

4/1/2014 (OM)

plots

4/4/2014 (PH)

4/8/2014 (TKN)NoN/A

8 (spare), stereo

  • Bad channels
    • Slot side, APV25 4, channel 46 (physical channel 46)
    • Hole side, APV25 4, channel 17 (physical channel 17)

L4-L6 Half-Module 02

L4-L6 Hybrid 9 / L4-L6 Hybrid 10 

Sensor 623 / Sensor 624

4/30/2014 (TKN)

4/30/2014 (TKN)

5/2/2014 (OM)5/6/2014 (FM)5/6/2014 (OM)plots5/7/2014 (PH)yesYes, on hole side, APV 3No

4 (T4), stereo

 

L4-L6 Half-Module 03

L4-L6 Hybrid 11 / L4-L6 Hybrid 12 

Sensor 625 / Sensor 626

5/6/2014 (TKN)

5/6/2014 (TKN)

5/7/2014 (PH)5/9/2014 (FM)5/9/2014 (TO/OM)plots5/13/2014 (VF/PH)yesYes, on slot side, APV 1No

4 (T4), axial

 

L4-L6 Half-Module 04

L4-L6 Hybrid 13 / L4-L6 Hybrid 14 

Sensor 627 / Sensor 629

5/6/2014 (PH)

5/6/2014 (TKN)

5/7/2014 (PH)5/9/2014 (FM)5/9/2014 (TO/OM)plots5/13/2014 (VF/PH)yesYes, on slot side, APV 4No

0 (spare), stereo

  • Bad channels
    • Slot side, APV25 2, channel 58 (physical channel 314)

L4-L6 Half-Module 05

L4-L6 Hybrid 16 / L4-L6 Hybrid 17 

Sensor 630 / Sensor 635

5/13/2014 (TKN)

5/13/2014 (TKN)

5/18/2014 (TKN/VF)5/19/2014 (FM)5/19/2014 (TO/OM)plots5/24/2014 (OM)yesNo08/27/2014 (OM) - Looks fine

1 (B4), stereo

 

L4-L6 Half-Module 06

L4-L6 Hybrid 19 / L4-L6 Hybrid 20 

Sensor 637 / Sensor 638

5/13/2014 (PH)

5/13/2014 (TKN)

5/18/2014 (TKN/VF)5/19/2014 (FM)5/19/2014 (TO/OM)plots5/24/2014 (OM)yesNoN/A

1 (B4), axial

Traces in H20 narrower from over-etching

L4-L6 Half-Module 07

L4-L6 Hybrid 15 / L4-L6 Hybrid 16 

Sensor 6400 / Sensor 643

5/15/2014 (TKN)

5/15/2014 (TKN)

5/18/2014 (TKN/VF)5/21/2014 (FM)5/21/2014 (TO/OM)plots5/24/2014 (OM)yesYes, on the slot side, APV 109/02/2014 (OM) - Looks fine

2 (B5), stereo

 

L4-L6 Half-Module 08

L4-L6 Hybrid 21 / L4-L6 Hybrid 22 

Sensor 645 / Sensor 646

5/15/2014 (PH)

5/15/2014 (TKN)

5/18/2014 (TKN/VF)5/21/2014 (FM)5/21/2014 (TO/OM)plots5/24/2014 (OM)yesYes, on hole side09/02/2014 (OM) - Looks fine

2 (B5), axial

 

L4-L6 Half-Module 09

L4-L6 Hybrid 8 / L4-L6 Hybrid 23 

Sensor 647 / Sensor 649

6/4/2014 (TKN)

6/4/2014 (TKN)

6/5/2014 (PH/VF)6/6/2014 (FM)6/6/2014 (TO/OM)plots6/6/2014 (OM)yesNo 

3 (B6), stereo

 

L4-L6 Half-Module 10

L4-L6 Hybrid 25 / L4-L6 Hybrid 26 

Sensor 652 / Sensor 653

6/4/2014 (TKN)

6/4/2014 (TKN)

6/5/2014 (PH/VF)6/6/2014 (FM)6/6/2014 (TO/OM)plots6/6/2014 (OM)no  

5 (T5), stereo

 

L4-L6 Half-Module 11

L4-L6 Hybrid 27 / L4-L6 Hybrid 28 

Sensor 655 / Sensor 656

6/6/2014 (TKN)

6/6/2014 (TKN)

6/9/2014 (OM)6/9/2014 (FM)6/9/2014 (OM)plots6/9/2014 (OM)no  

5 (T5), axial

A couple of connector pins on the slot side hybrid were bent when connecting the adapter board.  FM put the pins back in place and everything worked fine.

L4-L6 Half-Module 12

L4-L6 Hybrid 29 / L4-L6 Hybrid 30 

Sensor 657 / Sensor 658

6/6/2014 (TKN)

6/6/2014 (TKN)

6/9/2014 (OM)6/9/2014 (FM)6/9/2014 (OM)plots6/9/2014 (OM)yes  

3 (B6), axial

Before any of the APV's were wirebonded, HV test on the hole side of the half-module show the sensor "breaking down" at 500 V (current fluctuates between 10 uA - 100 uA). Leakage current looked OK at 400 V.  After the first set of wirebonds, the leakage current at 500 V dropped to ~80 nA and stayed at that level for duration of tests.

L4-L6 Half-Module 13L4-L6 Hybrid 45/ L4-L6 Hybrid 46Sensor 661 / Sensor 6638/22/2014 (TKN)

8/22/2014 (TKN)

8/25/2014 (OM)8/25/2014 (OM)8/25/2014 (OM)plots8/15/2014 (OM)yes  8 (spare), axial
  • Bad channels
    • Hole side, APV25 4, channel 110 (physical channel 110)
    • Hole side, APV25 3, channel 86 (physical channel 214)
L4 - L6 Half-Module 14L4-L6 Hybrid 47/ L4-L6 Hybrid 48 8/26/2014 (TKN)8/26/2014 (TKN)8/28/2014 (OM)8/28/2014 (FM)8/28/2014 (OM)plots9/04/2014 (OM)no  7 (spare), axialAPV wirebonds damaged. Repaired.
L4-L6 Half-Module 15L4-L6 Hybrid 49/ L4-L6 Hybrid 50Sensor 666 / Sensor 6688/26/2014 (OM)8/26/2014 (TKN)8/28/2014 (OM)8/28/2014 (FM)8/28/2014 (OM)plots9/04/2014 (OM)yes  7 (spare), stereo
  • Bad channels
    • Slot side, APV25 4, channel 52 (physical channel 52)
    • Slot side, APV25 4, channel 53 (physical channel 53)
L4-L6 Half-Module 16  8/29/2014 (TKN)8/29/2014 (TKN)9/04/2014 (OM)9/04/2014 (FM)9/04/2014 (OM)plots never  nope

APV 4 on the slot side has a chipped corner. The noise and baseline look fine, however, the response of the channels on cal group 2 is ~0. It's unclear if the low response is related to the chipped corner.

Damaged connector.

L4-L6 Half-Module 17  8/29/2014 (OM)8/29/2014 (TKN)9/04/2014 (OM)9/04/2014 (FM)9/04/2014 (OM)plots9/04/2014 (OM)yes  6 (T6), stereo 
L4-L6 Half-Module 18  9/03/2014 (TKN)9/03/2014 (TKN)9/04/2014 (OM)9/04/2014 (FM)9/04/2014 (OM)plots9/04/2014 (OM)no  6 (T6), axial 
L4-L6 Half-Module 19  9/03/2014 (TKN)9/03/2014 (TKN)9/04/2014 (OM)9/04/2014 (FM)9/04/2014 (OM)plots no  0 (spare), axial
  • Bad channels
    • Hole side, APV25 2, channel 109 (physical channel 365)

 

Half-module Channel Mapping

 

Link to DAQ page.

 

  • No labels