Location of DQM ROOT Files
Files for cooked runs are saved in
/volatile/hallb/hps/data/run2019/ConcurrentCook/${run}/dqm
of hps@ifarm (${run} represents run number)
Part of files are saved in
/group/hps/dqm-web/files
of hps@ifarm for browse through
https://hpsweb.jlab.org/dqm/dqm.php
(JLab account is required)
Location of scripts for DQM 2019:
/u/group/hps/production/data/Run2019/ConcurrentCook at hps@ifarm
Presentation PDF Files
Run 10129: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v9_2.cnf
Run 10130: Beam 150 nA; target 4 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v9_2.cnf
Run 10136: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v9_2.cnf
Run 10149: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v9_2.cnf
Run 10169: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v10.cnf
Run 10170: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v10.cnf
Run 10186: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v10.cnf
Run 10188:
Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v10.cnf
Run 10190: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by
HPS/Run2019/hps_v10.cnf
Run 10235: Beam 150 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10240: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10257: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10266: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10268: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10271: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10275: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10282: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10287: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10291: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v6_random_30kHz.trg
Run 10305: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10310: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10318: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10323: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10328: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10333: Beam 200 nA; target OUT; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v6_FEE_STRAIGHT
Run 10364: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10365: Beam 80 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10377: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10379: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10385: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10389: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10396: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v10.cnf
Run 10410: Beam 110 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_1.cnf
Run 10417: Beam 110 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_1.cnf
Run 10419: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10423: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10444: Beam 120 nA; target OUT; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10448: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10465: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10480: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10487: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10495: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10498: Beam 110 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10502: Beam 110 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10514: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10518: Beam 300 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10520: Beam 300 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10522: Beam 300 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10524: Beam 100 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10526: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10531: Beam 200 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10545: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10548: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10552: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10564: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10570: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10612: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10618: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10622: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10625: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_6.cnf
Run 10643: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10646: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v11_5_random_15kHz.cnf
Run 10648: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10654: Beam 80 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v11_5.cnf
Run 10657: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10660: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10662: Beam 80 nA; target OUT; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v6_FEE_STRAIGHT.trg
Run 10666: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10677: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10679: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10688: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10690: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10698: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10700: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v11_5_random_15kHz.trg
Run 10702: Beam 120 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10710: Beam 120 nA; target 8 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10711: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf; with different SVT bias HV setup
Run 10712: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
; with different SVT bias HV setup
Run 10713: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
; with different SVT bias HV setup
Run 10714: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
; with different SVT bias HV setup
Run 10717: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v13_FEE.trg
Run 10720: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10724: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10734: Beam 50 nA; target OUT; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/
hps_v13_FEE_STRAIGHT.trg
Run 10735: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf
Run 10740: Beam 120 nA; target 20 um; SVT Y-position 0.5 mm; Trigger by HPS/Run2019/hps_v12_1.cnf