The xrootd tools used by FGST are in the release directory of the glastdat user. Sourcing the wk_env script will set the PATH to a release bin directory and set the PYTHONPATH for the python packages.
% cd /u/gl/glastdat/releases/current/ % . bin/wk_env
The ScaRunOnHosts script will take a list of FGST xrootd servers and a command. It will ssh to all of the servers in the list and execute the command directly on the server. The basic usage is:
% ScaRunOnHosts -s wain018,wain034 -r -e -- <command> % ScaRunOnHosts -f glast -r -e -- <command>
It should be run from a release as described above. The available options are:
-p : ssh to all host in parallel
-w : wait for all hosts do be done. Only useful with -p option.
-e : Setup the release environment on the remote host. With out this option the
command to be run has to be found in the default PATH of the glastdat
-s srv1,srv2,..,srvn : list of servers to run the command
-f <flist> : read server list from a file. The file is looked for in /afs/slac.stanford.edu/g/glast/applications/xrootd/config/
The script reads from a file the list of recon files that can be purged from a xrootd server. Purging a file includes the following steps:
#) Check if file is on disk
#) Check if file is marked as migrated. On Solaris this means comparing a files mtime with the corresponding .lock files. On linux xattrs are used instead.
#) If the file is marked as migrated check in HPSS if the file exists and compare file sizes.
#) remove file (and .lock file) if the check in HPSS succeeded.
SrvPurgeFiles.sh [options] pass options: -l write output to log file -n number of files to purge -T test, print only command and exit pass: P202 | P300
Example:
% cd /u/gl/glastdat/releases/current % . bin/wk_env % ScaRunOnHosts -f glast -r -e -- SrvPurgeFiles.sh -l P202 % ScaRunOnHosts -f glast -r -e -- SrvPurgeFiles.sh -l P300
The above commands will ssh to all xrootd servers and do the purge. Log files are written to the directory /var/adm/mps/logs (Solaris) or /var/adm/frm/logs (Linux) and the logfile name is purge_file.YYYYMMDDTHHMMSS. As all output from SrvPurgeFiles.sh_ is written to a log file one will not see any output from the command above. The first(second) example would purge the recon files that are succeeded by the P202(P300) reprocessing.
ScaRunOnHosts -f glast -e -r -- SrvMigrateFiles.sh -b [-r] [-e]
The -r migrates the recon files, -e use the extra-backup file lists.
Mark file on server as migratable (Linux):
frm_admin mark -m /glast/Data/.....
Run migration
SrvMigrateFiles.sh <file-list>
ssh to all data server and tail the last few lines of the most recent migrate log file. Count the number of migrated files.
ScaRunOnHosts -f glast -e -r -- SrvMigrStat.sh
The migration tools check for a semaphore file (/var/adm/frm/STOP_MIGR or /var/adm/mps/STOP_MIGR) and will exit if it exists. To set remove or list the semaphore files on all servers run:
ScaRunOnHosts -f glast -e -r --SrvMigrateFlags.sh [list | rm | set]