Confluence will be down for maintenance June 14 2024 at 6AM PT.
2007-01-13 17:04 Stopped Pipeline Server (Unpatched, w/ 1 stream)
Restarted Pipeline Server with unpatched code
2007-01-13 17:15 Created 1 stream
2007-01-13 19:36 Created 1 stream
2007-01-13 20:58 Created 1 stream
2007-01-13 21:01 Server died, cursors exceeded:
Jan 13, 2007 9:01:03 PM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 13, 2007 9:01:03 PM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 13, 2007 9:01:11 PM org.glast.pipeline.server.Main$Loop loop
FINER: Checking for work...
Jan 13, 2007 9:01:11 PM org.glast.pipeline.server.Main$Loop loop
FINE: Found 23 items ready to be queued
java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:546)
at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1552)
at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1466)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1699)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.readObject(ObjectInputStream.java:348)
at oracle.jpub.reflect.Client.deserialize(Client.java:380)
at oracle.jpub.reflect.Client.invoke(Client.java:187)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
Jan 13, 2007 9:01:12 PM org.glast.pipeline.server.Main$Loop loop
FINE: Pipeline waiting for queue to finish
Jan 13, 2007 9:01:12 PM org.glast.pipeline.server.mail.MailReceiver$MailThread run
FINER: MailReciver thread interrupted
java.lang.InterruptedException: sleep interrupted
at java.lang.Thread.sleep(Native Method)
at org.glast.pipeline.server.mail.MailReceiver$MailThread.run(MailReceiver.java:125)
Exception in thread "main" java.sql.SQLException: java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at oracle.jpub.reflect.Client.invoke(Client.java:196)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
glast@glastlnx07 $
Streams were: 1168737292 1168745778 1168750649!plot-48.jpg!
2007-01-14 13:33 Restarted Pipeline Server with patched code
(Last part of 1 stream still running)
2007-01-14 14:14 Deleted previous test's streams from DB
Restarted Pipeline Server with patched code
2007-01-14 14:20 Created 1 stream (1168813237)
2007-01-14 15:17 Created 1 stream (1168816607)
2007-01-14 15:50 Created 1 stream (1168818646)
2007-01-14 16:55 Created 1 stream (1168822501)
2007-01-14 17:59 Created 1 stream (1168826339)
2007-01-14 18:48 Created 1 stream (1168829360)
Pipeline Died:
Jan 14, 2007 6:49:12 PM org.glast.pipeline.server.Main$Loop loop
FINER: Checking for work...
Jan 14, 2007 6:49:12 PM org.glast.pipeline.server.Main$Loop loop
FINER: Sleeping for 10 seconds...
Jan 14, 2007 6:49:21 PM org.glast.pipeline.server.Main createStream
FINE: Received createStream DRP_monitoring 1168829360
Jan 14, 2007 6:49:21 PM org.glast.pipeline.server.Main$Loop loop
FINER: Checking for work...
Jan 14, 2007 6:49:21 PM org.glast.pipeline.server.Main$Loop loop
FINE: Found 1 items ready to be queued
java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:546)
at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1552)
at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1466)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1699)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.readObject(ObjectInputStream.java:348)
at oracle.jpub.reflect.Client.deserialize(Client.java:380)
at oracle.jpub.reflect.Client.invoke(Client.java:187)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
Jan 14, 2007 6:49:21 PM org.glast.pipeline.server.Main$Loop loop
FINE: Pipeline waiting for queue to finish
Jan 14, 2007 6:49:21 PM org.glast.pipeline.server.mail.MailReceiver$MailThread run
FINER: MailReciver thread interrupted
java.lang.InterruptedException: sleep interrupted
at java.lang.Thread.sleep(Native Method)
at org.glast.pipeline.server.mail.MailReceiver$MailThread.run(MailReceiver.java:125)
Exception in thread "main" java.sql.SQLException: java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at oracle.jpub.reflect.Client.invoke(Client.java:196)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
2007-01-15 23:19 Deleted previous test's streams from DB
Restarted Pipeline Server with patch2 code
2007-01-15 23:30 Created 1 stream (1168932258)
2007-01-16 01:48 Created 1 stream (1168939430)
2007-01-16 03:27 Created 1 stream (1168946635)
2007-01-16 05:31 Created 1 stream (1168953840)
2007-01-16 07:29 Created 1 stream (1168961041)
2007-01-16 09:00 Attempted to create more than one stream of same name.
Local machine network crashed.
Pipeline Server crashed
<<plot167.jpg>>
2007-01-16 09:13 Restarted Pipeline Server with patch2 code
(Forgot to delete active stream(s)
2007-01-16 09:15 Deleted previous test's streams from DB
Restarted Pipeline Server with patch2 code
(Ran out last bits of deleted streams (mail))
2007-01-16 09:20 Restarted Pipeline Server with patch2 code
2007-01-16 09:30 Created 1 stream (1168968635)
Created 1 stream (1168968661)
Created 1 stream (1168968666)
Created 1 stream (1168968671)
2007-01-16 010:20 Created 1 stream of ComplexExample
2007-01-16 010:27 Created 5 streams of ComplexExample
2007-01-16 010:28 Created 5 streams of DRP_Monitoring
Exception thrown:
Jan 16, 2007 10:36:30 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution starting
Jan 16, 2007 10:36:31 AM org.glast.pipeline.server.mail.MailReceiver checkForMail
FINER: Found 0 messages in mail queue
Jan 16, 2007 10:36:32 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
INFO: Gooodbye from stepA
java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:546)
at java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1552)
at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1466)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1699)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:1908)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:1832)
at java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:1719)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1305)
at java.io.ObjectInputStream.readObject(ObjectInputStream.java:348)
at oracle.jpub.reflect.Client.deserialize(Client.java:380)
at oracle.jpub.reflect.Client.invoke(Client.java:187)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
Jan 16, 2007 10:36:33 AM org.glast.pipeline.server.Main$Loop loop
FINE: Pipeline waiting for queue to finish
Jan 16, 2007 10:36:41 AM org.glast.pipeline.server.mail.MailReceiver checkForMail
FINER: Found 0 messages in mail queue
Jan 16, 2007 10:36:51 AM org.glast.pipeline.server.mail.MailReceiver checkForMail
FINER: Found 0 messages in mail queue
Jan 16, 2007 10:36:53 AM org.glast.pipeline.server.mail.MailReceiver$MailThread run
FINER: MailReciver thread interrupted
java.lang.InterruptedException: sleep interrupted
at java.lang.Thread.sleep(Native Method)
at org.glast.pipeline.server.mail.MailReceiver$MailThread.run(MailReceiver.java:125)
Exception in thread "main" java.sql.SQLException: java.io.InvalidClassException: oracle.jdbc.driver.OracleSQLException; local class incompatible: stream classdesc serialVersionUID = -3944732340976732163, local class serialVersionUID = -7311942150159538740
at oracle.jpub.reflect.Client.invoke(Client.java:196)
at org.glast.pipeline.server.sql.spclient.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance.java:42)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:733)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.Main$Loop.doWork(Main.java:198)
at org.glast.pipeline.server.Main$Loop.loop(Main.java:142)
at org.glast.pipeline.server.Main$Loop.access$100(Main.java:116)
at org.glast.pipeline.server.Main.doLoop(Main.java:113)
at org.glast.pipeline.server.Main.main(Main.java:82)
Jan 16, 2007 10:36:53 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 16, 2007 10:36:54 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Another exception:
FINE: Execution starting
java.sql.SQLException: Invalid State Transition (READY to READY)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:165)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:89)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.checkProcessDependents(SPProcessInstance:609)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:189)
at sun.reflect.GeneratedMethodAccessor2.invoke(Unknown Source)
at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java)
at java.lang.reflect.Method.invoke(Method.java)
at oracle.jpub.reflect.Server.invoke(Server.java)
at oracle.jpub.reflect.Server.invoke(Server.java)
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
SEVERE: Uncaught exception while running jython script
org.glast.pipeline.server.sql.DatabaseUtilities$InvalidStatusTransitionException: Error during pipeline database access
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:737)
at org.glast.pipeline.server.sql.DatabaseUtilities.setProcessInstanceStatus(DatabaseUtilities.java:745)
at org.glast.pipeline.server.process.ProcessInstanceExecutor.setState(ProcessInstanceExecutor.java:74)
at org.glast.pipeline.server.process.ProcessInstanceExecutor.setState(ProcessInstanceExecutor.java:64)
at org.glast.pipeline.server.process.jython.JythonProcessExecutor.run(JythonProcessExecutor.java:111)
at java.util.concurrent.ThreadPoolExecutor$Worker.runTask(ThreadPoolExecutor.java:650)
at java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:675)
at java.lang.Thread.run(Thread.java:595)
Caused by: java.sql.SQLException: Invalid State Transition (READY to READY)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:165)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:89)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.checkProcessDependents(SPProcessInstance:609)
at org.glast.pipeline.server.sql.sp.SPProcessInstance.setProcessInstanceStatus(SPProcessInstance:189)
at sun.reflect.GeneratedMethodAccessor2.invoke(Unknown Source)
at sun.reflect.DelegatingMethodAccessorImpl.invoke(DelegatingMethodAccessorImpl.java)
at java.lang.reflect.Method.invoke(Method.java)
at oracle.jpub.reflect.Server.invoke(Server.java)
at oracle.jpub.reflect.Server.invoke(Server.java)
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution starting
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution starting
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
FINE: Execution completed
Jan 16, 2007 10:40:49 AM org.glast.pipeline.server.logging.ProcessInstanceLogger doLog
!plot-167.jpg!