Would you like to help test Confluence and Jira updates? Please fill out the form here: https://forms.gle/5TbSqvYYCnTyyxSN7
Initially, these instructions will be for installing on rhel6-64 and using the LSF-based Pipeline-II infrastructure.
These instructions are also available in this repo in users/jchiang in SLAC CVS.
In tcsh, source the setup script containing
setenv BINDIR redhat6-x86_64-64bit-gcc44-Optimized setenv INST_DIR /afs/slac/g/glast/ground/ASP/prod/ASP-07-00-00 setenv GLAST_EXT /afs/slac/g/glast/ground/GLAST_EXT/redhat6-x86_64-64bit-gcc44 astrotools source ${INST_DIR}/bin/${BINDIR}/_setup.csh setenv TNS_ADMIN /u/gl/glast/oracle/admin setenv ORACLE_HOME /afs/slac.stanford.edu/package/oracle/f/11.1.0/amd64_linux26/11.1.0 setenv LD_LIBRARY_PATH ${ORACLE_HOME}/lib:${LD_LIBRARY_PATH} setenv PYTHONPATH /afs/slac/g/glast/ground/PipelineConfig/ASP/python/lib/python2.6_x86_64/site-packages:/afs/slac/g/glast/ground/PipelineConfig/GPLtools/prod/python:${PYTHONPATH} setenv PATH ${INST_DIR}/bin/${BINDIR}:${PATH} setenv PFILES ".;${BASE_DIR}/syspfiles:/dev/null" setenv CALDB /afs/slac.stanford.edu/g/glast/ground/ASP/prod/fermitools_irfs/irfs/caldb/CALDB setenv CALDBCONFIG ${CALDB}/software/tools/caldb.config setenv CALDBALIAS ${CALDB}/software/tools/alias_config.fits set prompt="[ASP]$ "
Install the ASP distribution in the ASP/prod area on afs, where ASP-vv-rr-pp is the tag, e.g., ASP-07-00-00:
ssh rhel6-64 cd /afs/slac/g/glast/ground/ASP/prod cvs co -r ASP-vv-rr-pp ASP-scons mv ASP-scons ASP-vv-rr-pp
Edit pyASP/python/databaseAccess.py to enable the asp_prod oracle wallet user, i.e., comment the relevant code block like this:
#try: # # # # Reset the default to prod if running in the PROD pipeline. # # # if os.environ['PIPELINESERVER'] == "PROD": # asp_default = asp_prod #except KeyError: # # # # We may be running interactively (and did not set PIPELINESERVER), # # so keep "DEV" as the default. # # # print "Warning: Using dev db tables." # pass
cd to the associated ScienceTools build in afs, edit the Makefile entry for ASP_prod to point to the ASP tag, build ASP_prod, and return to /afs/slac/g/glast/ground/ASP/prod:
pushd /afs/slac/g/glast/ground/releases/volume02/ScienceTools-09-32-05 <edit Makefile> make ASP_prod popd
Move the ASP symlink in /afs/slac/g/glast/ground/ASP/prod to point to the tagged installation:
ln -sf ASP-vv-rr-pp ASP
Ensure the location of aspLauncher.sh is correct (This is used by L1Proc to launch the ASP pipelines.):
cd /afs/slac/g/glast/ground/links/data/ASP ln -sf /afs/slac/g/glast/ground/ASP/prod/ASP/bin/redhat6-x86_64-64bit-gcc44-Optimized/aspLauncher.sh
Ensure the location of ingestNoticeQueue_rh6-64.sh is correct:
cd /afs/slac/g/glast/ground/ASP/GCN_Archive/ ln -sf /afs/slac/g/glast/ground/ASP/prod/ASP/bin/redhat6-x86_64-64bit-gcc44-Optimized/ingestNoticeQueue.sh ingestNoticeQueue_rh6-64.sh
Check that the notices are being properly ingested by the cron job at 5 min intervals (See Current Cronjobs for chronjob locations.)
ssh fermilnx-v05 cd /scratch/ASP ls -l
Ensure the location of make_monitored_source_list.sh is correct. This is called by makeDrpLcTables.sh on rhel6-64 via trscrontab.:
cd /afs/slac/g/glast/ground/links/data/ASP ln -sf /afs/slac/g/glast/ground/ASP/prod/ASP/bin/redhat6-x86_64-64bit-gcc44-Optimized/make_monitored_source_list.sh
The preceding relocated .sh scripts need to be edited to set the INST_DIR environment variable internally:
export INST_DIR=/afs/slac/g/glast/ground/ASP/prod/ASP-vv-rr-pp
Edit make_monitored_source_list.sh to define DRPMONITORINGROOT env var:
export DRPMONITORINGROOT=/afs/slac/g/glast/ground/ASP/prod/ASP-vv-rr-pp/drpMonitoring
Copy the GCN_Notice_processor.py script for the procmail GCN ingest process:
cd /afs/slac/g/glast/ground/PipelineConfig/ASP/bin cp /afs/slac/g/glast/ground/ASP/prod/ASP/grbASP/python/GCN/GCN_Notice_processor.py .
Install any new xml task defs into P-II:
aspLauncher/xml/AspInsertIntervals.xml aspLauncher/xml/AspLauncher.xml asp_pgwave/xml/PGWAVE.xml drpMonitoring/xml/DRP_monitoring.xml grbASP/xml/GRB_afterglow.xml grbASP/xml/GRB_afterglow_launcher.xml grbASP/xml/GRB_blind_search.xml grbASP/xml/GRB_refinement.xml grbASP/xml/GRB_refinement_launcher.xml
Update the relevant configs in the db tables:
GRB_ASP_CONFIG STARTDATE=456833103 456845884 ENDDATE=618796803 IRFS=P8R2_TRANSIENT020_V6 THRESHOLD=319 SOURCEMONITORINGCONFIG STARTDATE=456840000 ENDDATE=618796803 IRFS=P8R2_SOURCE_V6 ST_VERSION=10-01-01 ASP_VERSION=07-00-00 FT1_FILTER='(EVENT_CLASS & o200) != o0'