Date

Attendees

Goals

  • Jorge's piezo measurements + plans
  • John+Clarice's 1.3 GHz measurement
  • Sonya's firmware updates

Discussion items

TimeItemWhoNotes
20Jorge's piezos

Jorge

  • Jorge presented on his piezo ML feedback work.
    • Previous work had models made/trained on simulation data.
    • Took measured data on CM20, 8, 7, 19 (cav 1-2).
    • Will now train models with measured data.
  • Dan - when do you want to try this on a real cavity
    • Jorge - maybe in a month or two. Goal of the controller is to set amp and phase. 
    • Sebastian - piezo will work harder than it is now? Should we worry about lifetime?
    • Jorge - paper on piezo lifetime are out there. Should be considered/calculated since piezo will be more active. Yuri paper?
  • Want to try this on CM19 cavities with microphonics
    • If it works, will have to add it to firmware
151.3 GHz measJohn/Clarice
  • Clarice gave slides on HOM 1.3GHz measurement. 
    • Sebastian - acceptance test should have data on how the notch filter is tuned.
      • We can use that to spot check another another CM
    • John - were test at temperature?
      • Sebastian and Janice - acceptance test was done at both
    • Sebastian pulled up traveler to see if power data is there. Qext is included
    • John - work backwards from Qext to get power?
    • Sebastian - No we should check trends only / correlate low Q to higher power coupled out, don’t back calculate
    • Janice - We can check if this matches the measurements John/Clarice made
  • Sebastian/Jing - There were some HOM measurements during commissioning.
  • All other CMs are terminated at the CM with attenuators/loads at the flange
  • Jing - load on flange is able to handle 1W
    • John - installed over 1W attenuators at the flange
10Software updatesSonya
  • Diagnostics were added to CM32, we shouldn't notice a difference
  • DFCold landing PV will be changed to an integer
  • CM32 will also get new interlocks (only this PV)
    • LO Level
  • This shouldn't impact things much 

Action items

  •