10 min | Cryo plant issues | Sebastian | - Attempted to have firmware update today
- Failed bc remote access failed
- Trouble shooting today and will try again tomorrow at 6am
- Last pump down failed again yesterday after motor drive replaced.
- Working on replacing filters before trying again / hope this will keep us below threshold
- Not confident we will get to 2K today.
- Compressor 6 is leaking on oil hoses, and it's getting worse.
- They want to switch parts/compressor, but if hose fail/burst, then cryo plant is down for a longer time.
- There may be a fast warm up / detune if this happens.
- Sonya has bypass scripts if needed
|