Validation After Leap  Second Upgrade

GlastRelease 17-35-24lp29 is now the current L1proc version of GR and will be used as our baseline.

GlastRelease 17-35-24-gr35 is the new candidate GR

Johan's findings comparing the system test results of the RHEL4 builds of both tags are available here.  In particular we need to clean up the Overlay system tests and determine why there are different numbers of events between the two versions in some of the low-level plots.

Discrepancy in number of entries in low-level plots

While the number of events simulated in 17-35-24-lp29 and 17-35-24-gr35 are identical across the various system tests - the events generated are not.  Here are some examples:

17-35-24-lp29

AllGamma

FluxAlg              INFO Computed Rate: 37.6639 Hz
                         Source ID   Source Name                  counts
                                -1   all_gamma                     40000
G4Generator          INFO finalize:
TkrCalibAlg          INFO           Finalize TkrCalibAlg
TkrDigiMcToHitAlg    INFO finalize
TkrDigiNoiseAlg      INFO finalize
TkrDigiChargeAlg     INFO finalize
TkrDigiHitRemov...   INFO finalize
TkrDigiHitToDig...   INFO finalize
TkrDigiAlg           INFO finalize
TriggerAlg           INFO Totals triggered/ processed: 40000/40000
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ---- --- --- --- --- ---
               0 31862     0     0     0     0     0
               2  3024     0     0     0  3024     0
               3   983     0     0     0   983   983
               4  1606     0     0  1606     0     0
               6  1184     0     0  1184  1184     0
               7   148     0     0   148   148   148
              12   450     0   450   450     0     0
              14   387     0   387   387   387     0
              15   140     0   140   140   140   140
              16    58    58     0     0     0     0
              18    56    56     0     0    56     0
              19    96    96     0     0    96    96
              20     1     1     0     1     0     0
              22     1     1     0     1     1     0
              23     2     2     0     2     2     2
              28     1     1     1     1     0     0
              31     1     1     1     1     1     1
                ---- --- --- --- --- ---
            tot: 40000   216   979  3921  6022  1370
trigger              INFO counted 40000 times

BackGndMixDC2

FluxAlg              INFO Computed Rate: 130128 Hz
                         Source ID   Source Name                  counts
                                 0   CrProtonPrimary                6168
                                 1   CrProtonReentrant              1464
                                 2   CrProtonSplash                 1283
                              1000   CrElectronPrimary                60
                              1001   CrElectronReentrant            6490
                              1002   CrElectronSplash               6456
                              2000   CrPositronPrimary                 6
                              2001   CrPositronReentrant            6898
                              2002   CrPositronSplash               6918
                              3000   CrAlpha                         833
                              4000   CrHeavyIon                      123
                              5000   Earth10                        3301
G4Generator          INFO finalize:
TkrCalibAlg          INFO           Finalize TkrCalibAlg
TkrDigiMcToHitAlg    INFO finalize
TkrDigiNoiseAlg      INFO finalize
TkrDigiChargeAlg     INFO finalize
TkrDigiHitRemov...   INFO finalize
TkrDigiHitToDig...   INFO finalize
TkrDigiAlg           INFO finalize
TriggerAlg           INFO Totals triggered/ processed: 40000/40000
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ---- --- --- --- --- ---
               0 35839     0     0     0     0     0
               2   690     0     0     0   690     0
               3  2417     0     0     0  2417  2417
               4   187     0     0   187     0     0
               6    68     0     0    68    68     0
               7   424     0     0   424   424   424
              12     9     0     9     9     0     0
              14     1     0     1     1     1     0
              15    40     0    40    40    40    40
              16   144   144     0     0     0     0
              18    10    10     0     0    10     0
              19    96    96     0     0    96    96
              20     7     7     0     7     0     0
              22     3     3     0     3     3     0
              23    53    53     0    53    53    53
              31    12    12    12    12    12    12
                ---- --- --- --- --- ---
            tot: 40000   325    62   804  3814  3042
trigger              INFO counted 40000 times

17-35-24-gr35

AllGamma

FluxAlg              INFO Computed Rate: 38.0247 Hz
                         Source ID   Source Name                  counts
                                -1   all_gamma                     40000
G4Generator          INFO finalize:
TkrCalibAlg          INFO           Finalize TkrCalibAlg
TkrDigiMcToHitAlg    INFO finalize
TkrDigiNoiseAlg      INFO finalize
TkrDigiChargeAlg     INFO finalize
TkrDigiHitRemov...   INFO finalize
TkrDigiHitToDig...   INFO finalize
TkrDigiAlg           INFO finalize
TriggerAlg           INFO Totals triggered/ processed: 40000/40000
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ----- --- --- --- --- ----
               0 31749     0     0     0     0     0
               2  3136     0     0     0  3136     0
               3   898     0     0     0   898   898
               4  1607     0     0  1607     0     0
               6  1234     0     0  1234  1234     0
               7   145     0     0   145   145   145
              11     1     0     1     0     1     1
              12   494     0   494   494     0     0
              14   388     0   388   388   388     0
              15   129     0   129   129   129   129
              16    67    67     0     0     0     0
              18    65    65     0     0    65     0
              19    84    84     0     0    84    84
              22     1     1     0     1     1     0
              23     1     1     0     1     1     1
              31     1     1     1     1     1     1
                ----- --- --- --- --- ----
            tot: 40000   219  1013  4000  6083  1259
trigger              INFO counted 40000 times

BackGndMixDC2

FluxAlg              INFO Computed Rate: 131383 Hz
                         Source ID   Source Name                  counts
                                 0   CrProtonPrimary                6132
                                 1   CrProtonReentrant              1462
                                 2   CrProtonSplash                 1328
                              1000   CrElectronPrimary                54
                              1001   CrElectronReentrant            6463
                              1002   CrElectronSplash               6455
                              2000   CrPositronPrimary                 2
                              2001   CrPositronReentrant            6986
                              2002   CrPositronSplash               6834
                              3000   CrAlpha                         889
                              4000   CrHeavyIon                      107
                              5000   Earth10                        3288
G4Generator          INFO finalize:
TkrCalibAlg          INFO           Finalize TkrCalibAlg
TkrDigiMcToHitAlg    INFO finalize
TkrDigiNoiseAlg      INFO finalize
TkrDigiChargeAlg     INFO finalize
TkrDigiHitRemov...   INFO finalize
TkrDigiHitToDig...   INFO finalize
TkrDigiAlg           INFO finalize
TriggerAlg           INFO Totals triggered/ processed: 40000/40000
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ---- --- --- --- --- ---
               0 36067     0     0     0     0     0
               2   607     0     0     0   607     0
               3  2299     0     0     0  2299  2299
               4   170     0     0   170     0     0
               6    71     0     0    71    71     0
               7   417     0     0   417   417   417
              12     9     0     9     9     0     0
              14     3     0     3     3     3     0
              15    32     0    32    32    32    32
              16   158   158     0     0     0     0
              18    10    10     0     0    10     0
              19   105   105     0     0   105   105
              20     8     8     0     8     0     0
              22     2     2     0     2     2     0
              23    37    37     0    37    37    37
              28     1     1     1     1     0     0
              31     4     4     4     4     4     4
                ---- --- --- --- --- ---
            tot: 40000   325    49   754  3587  2894
trigger              INFO counted 40000 times

  

Validation After Upgrading to OBF B3-0-0-gl1

GlastRelease 17-35-24-lp28 is now the current L1proc version of GR and will be used as our basline.  It uses FSW B3-0-0 (gl1) as the OBF external.  It is built via SCons on glastlnx14 (RHEL4-32).

GlastRelease 17-35-24-gr31 is the new candidate GR moving back to OBF B3-0-0 and includes patches to Overlay and the event display handling.

First Attempts

GlastRelease 17-35-24-lp22 is the current L1proc version of GR and will be used as our baseline.  It uses FSW B1-3-0 as the base of our OBF external.  It is built on glastlnx14 (RHEL4-32) via SCons.

GlastRelease-17-35-24-gr27 is the current test candidate of GR that is built on RHEL4-32 and RHEL5-32 via SCons.  This required upgrading to FSW B3-0-0 for OBF and Gaudi v21r7-gl1.

GlastRelease-17-35-24-gr30 is identical to gr27, but falls back to OBF B1-1-3 for now, while JJ evaluates the cause for the differences in the OBF filter results.

System Tests

GlastRelease-17-35-24-gr30 versus GlastRelease-17-35-24-lp22

 http://glast-ground.slac.stanford.edu/SystemTests/?releaseVersionId=13221

The many differences are likely attributable to the different random number seeds applied.  A new run is being prepared.

Testing Real (evt) Data Take 2 May 7, 2012

Backed off to OBF B1-1-3 for now, continuing to test RHEL4 builds of 17-35-24-lp22 versus 17-35-24-gr30.  Digi step performed on dole0030 and recon on kiso0067 as before.

Now the digitization logs concerning the OBF data are identical.  Comparing the reconstruction logs, one notices that the merit values are not identical across the board:

GR 17-35-24-lp22 

RootTupleSvc WARNING Found 71 bad events: table of bad values follows
Name count
AcdActiveDist3DErr 45
AcdTkr1ActiveDistErr 46
CalCfpCalChiSq 1
CalCfpCalEffRLn 1

GR 17-35-24-gr30 

RootTupleSvc WARNING Found 70 bad events: table of bad values follows
Name count
AcdActiveDist3DErr 45
AcdTkr1ActiveDistErr 46

We then tried using Luca Baldini's meritDiff.py to compare the resulting merit files (this is available in CVS users/lbaldini/MeritDiff):

MeritUtils/python/meritDiff.py -n 66429 -d 1e-3 GR-17-35-24-lp22-rhel4build-merit.root test-newGaudi/test-gr30/GR-17-35-24-gr30-rhel4build-merit.root

*** Event @ row 15:
               CalCfpCalEnergy:      1580.19 vs. 1229.07
*** Event @ row 20:
            CalCfpCalFitErrFlg:          4.0 vs. 0.0

So the differences seem centered on the CalCfp** calculations.

System tests for 17-35-24-gr30 versus 17-35-24-lp22 have been run.

Testing Real (evt) Data Processing

Starting with RHEL4-32 optimized builds of both GR 17-35-24-lp22 (lp22) and 17-35-24-gr27 (gr27) we digitized and recon'ed evt file:  

The digi step was done on dole0030 while recon took place on kiso0067

The results were close, but not precisely identical, the number of events processed is identical (66429).  The resulting log files are attached to this Confluence doc and some interesting differences are highlighted here:

GR 17-35-24-lp22

EventSelector        INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr         INFO No more events in event selection
TriggerAlg           INFO Totals triggered/ processed: 66429/66429
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ---- --- --- --- --- ---
               0   723     0     0     0     0     0
               2 46357     0     0     0 46357     0
               3  2279     0     0     0  2279  2279
               4     9     0     0     9     0     0
               6  7565     0     0  7565  7565     0
               7  1997     0     0  1997  1997  1997
              12    65     0    65    65     0     0
              14  1106     0  1106  1106  1106     0
              15  4337     0  4337  4337  4337  4337
              18     1     1     0     0     1     0
              19    71    71     0     0    71    71
              22     1     1     0     1     1     0
              23   284   284     0   284   284   284
              28     1     1     1     1     0     0
              31  1633  1633  1633  1633  1633  1633
                ---- --- --- --- --- ---
            tot: 66429  1991  7142 16998 65631 10601
EbfWriter            INFO Wrote 66429 Total Events
OnboardFilter.G...   INFO -- Gamma Filter Status Word bit frequency table --
    GFC_V3_STATUS_M_GEM_THROTTLE        = 10077
    GFC_V3_STATUS_M_GEM_TKR             = 66020
    GFC_V3_STATUS_M_GEM_CALLO           = 16734
    GFC_V3_STATUS_M_GEM_CALHI           = 7364
    GFC_V3_STATUS_M_GEM_CNO             = 1991
    GFC_V3_STATUS_M_ACD_TOP             = 10069
    GFC_V3_STATUS_M_ACD_SIDE            = 22182
    GFC_V3_STATUS_M_ACD_SIDE_FILTER     = 9894
    GFC_V3_STATUS_M_TKR_EQ_1            = 15654
    GFC_V3_STATUS_M_TKR_GE_2            = 21361
    GFC_V3_STATUS_M_RSVD_10             = 0
    GFC_V3_STATUS_M_TKR_LT_2_ELO        = 4253
    GFC_V3_STATUS_M_TKR_SKIRT           = 8
    GFC_V3_STATUS_M_TKR_EQ_0            = 24
    GFC_V3_STATUS_M_TKR_ROW2            = 28
    GFC_V3_STATUS_M_TKR_ROW01           = 49
    GFC_V3_STATUS_M_TKR_TOP             = 207
    GFC_V3_STATUS_M_SIDE                = 101
    GFC_V3_STATUS_M_TOP                 = 170
    GFC_V3_STATUS_M_ZBOTTOM             = 45
    GFC_V3_STATUS_M_ERR_CTB             = 331
    GFC_V3_STATUS_M_SPLASH_1            = 2113
    GFC_V3_STATUS_M_E350_FILTER_TILE    = 32
    GFC_V3_STATUS_M_E0_TILE             = 73
    GFC_V3_STATUS_M_EL0_ETOT_HI         = 3755
    GFC_V3_STATUS_M_EL0_ETOT_LO         = 9706
    GFC_V3_STATUS_M_LO_ENERGY           = 20328
    GFC_V3_STATUS_M_HI_ENERGY           = 3688
    GFC_V3_STATUS_M_SPLASH_0            = 516
    GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
    GFC_V3_STATUS_M_NON_PHYSICS         = 171
    GFC_V3_STATUS_M_VETOED              = 4000
OnboardFilter.M...   INFO -- MIP Filter Status Word bit frequency table --
    MFC_STATUS_M_STAGE_GEM           = 66428
    MFC_STATUS_M_STAGE_ACD           = 0
    MFC_STATUS_M_STAGE_DIR           = 0
    MFC_STATUS_M_STAGE_CAL           = 0
    MFC_STATUS_M_STAGE_XCAL          = 0
    MFC_STATUS_M_MULTI_PKT           = 0
    MFC_STATUS_M_ERR_CAL             = 0
    MFC_STATUS_M_ERR_CTB             = 0
    MFC_STATUS_M_ERR_DIR             = 0
    MFC_STATUS_M_RSVD_09             = 0
    MFC_STATUS_M_RSVD_10             = 0
    MFC_STATUS_M_RSVD_11             = 0
    MFC_STATUS_M_RSVD_12             = 0
    MFC_STATUS_M_RSVD_13             = 0
    MFC_STATUS_M_RSVD_14             = 0
    MFC_STATUS_M_RSVD_15             = 0
    MFC_STATUS_M_RSVD_16             = 0
    MFC_STATUS_M_RSVD_17             = 0
    MFC_STATUS_M_RSVD_18             = 0
    MFC_STATUS_M_RSVD_19             = 0
    MFC_STATUS_M_RSVD_20             = 0
    MFC_STATUS_M_RSVD_21             = 0
    MFC_STATUS_M_RSVD_22             = 0
    MFC_STATUS_M_RSVD_23             = 0
    MFC_STATUS_M_RSVD_24             = 0
    MFC_STATUS_M_RSVD_25             = 0
    MFC_STATUS_M_NO_TKR_ADJ          = 0
    MFC_STATUS_M_LYR_COUNTS          = 0
    MFC_STATUS_M_NO_ACD_TKR          = 63371
    MFC_STATUS_M_GEM_NOTKR           = 501
    MFC_STATUS_M_GEM_CNO             = 2556
    MFC_STATUS_M_VETOED              = 66428
OnboardFilter.H...   INFO -- HIP Filter Status Word bit frequency table --
    HFC_STATUS_M_STAGE_GEM           = 66429
    HFC_STATUS_M_STAGE_DIR           = 0
    HFC_STATUS_M_STAGE_CAL           = 0
    HFC_STATUS_M_STAGE_CAL_ECHK      = 0
    HFC_STATUS_M_STAGE_CAL_LCHK      = 0
    HFC_STATUS_M_MULTI_PKT           = 0
    HFC_STATUS_M_ERR_CAL             = 0
    HFC_STATUS_M_ERR_CTB             = 0
    HFC_STATUS_M_ERR_DIR             = 0
    HFC_STATUS_M_RSVD_09             = 0
    HFC_STATUS_M_RSVD_10             = 0
    HFC_STATUS_M_RSVD_11             = 0
    HFC_STATUS_M_RSVD_12             = 0
    HFC_STATUS_M_RSVD_13             = 0
    HFC_STATUS_M_RSVD_14             = 0
    HFC_STATUS_M_RSVD_15             = 0
    HFC_STATUS_M_RSVD_16             = 0
    HFC_STATUS_M_RSVD_17             = 0
    HFC_STATUS_M_RSVD_18             = 0
    HFC_STATUS_M_RSVD_19             = 0
    HFC_STATUS_M_RSVD_20             = 0
    HFC_STATUS_M_RSVD_21             = 0
    HFC_STATUS_M_RSVD_22             = 0
    HFC_STATUS_M_RSVD_23             = 0
    HFC_STATUS_M_RSVD_24             = 0
    HFC_STATUS_M_RSVD_25             = 0
    HFC_STATUS_M_LYR_ENERGY          = 0
    HFC_STATUS_M_LYR_COUNTS          = 0
    HFC_STATUS_M_GEM_NOTKR           = 0
    HFC_STATUS_M_GEM_NOCALLO         = 75
    HFC_STATUS_M_GEM_NOCNO           = 66354
    HFC_STATUS_M_VETOED              = 66429
OnboardFilter.D...   INFO -- DFC Filter bit frequency table --
    Status Bit                         Value
    DFC_STATUS_M_STAGE_GEM             66429
    Veto Bit Summary
    Trigger Name                           Count
    DFC_STATUS_M_GEM_CLASSES           66429
    DFC_STATUS_M_VETOED                66429
OnboardFilter        INFO Encountered 0 events with no ebf data

GR 17-35-24-gr27 

EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
ApplicationMgr INFO Application Manager Stopped successfully
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
---- --- --- --- --- ---
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events
OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –

GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000
OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –

MFC_STATUS_M_STAGE_GEM = 66429
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 14156
MFC_STATUS_M_STAGE_CAL = 14156
MFC_STATUS_M_STAGE_XCAL = 14156
MFC_STATUS_M_MULTI_PKT = 1011
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 7361
MFC_STATUS_M_LYR_COUNTS = 11972
MFC_STATUS_M_NO_ACD_TKR = 49867
MFC_STATUS_M_GEM_NOTKR = 409
MFC_STATUS_M_GEM_CNO = 1997
MFC_STATUS_M_VETOED = 64245
OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –

HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 1918
HFC_STATUS_M_STAGE_CAL = 1918
HFC_STATUS_M_STAGE_CAL_ECHK = 1918
HFC_STATUS_M_STAGE_CAL_LCHK = 687
HFC_STATUS_M_MULTI_PKT = 1397
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 1191
HFC_STATUS_M_LYR_COUNTS = 281
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 72
HFC_STATUS_M_GEM_NOCNO = 64439
HFC_STATUS_M_VETOED = 65983
OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count
DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429
OnboardFilter INFO Encountered 0 events with no ebf data

Next we built GlastRelease-17-35-24-gr30 which fell back to OBF B1-1-3-gl7.  Now the OBF results in logs are indeed identical.

GR 17-35-24-lp22 

EventSelector        INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr         INFO No more events in event selection
TriggerAlg           INFO Totals triggered/ processed: 66429/66429
             bit frequency: all events
           value count   CNO CALHI CALLO   TKR   ROI
                ---- --- --- --- --- ---
               0   723     0     0     0     0     0
               2 46357     0     0     0 46357     0
               3  2279     0     0     0  2279  2279
               4     9     0     0     9     0     0
               6  7565     0     0  7565  7565     0
               7  1997     0     0  1997  1997  1997
              12    65     0    65    65     0     0
              14  1106     0  1106  1106  1106     0
              15  4337     0  4337  4337  4337  4337
              18     1     1     0     0     1     0
              19    71    71     0     0    71    71
              22     1     1     0     1     1     0
              23   284   284     0   284   284   284
              28     1     1     1     1     0     0
              31  1633  1633  1633  1633  1633  1633
                ---- --- --- --- --- ---
            tot: 66429  1991  7142 16998 65631 10601
EbfWriter            INFO Wrote 66429 Total Events
OnboardFilter.G...   INFO -- Gamma Filter Status Word bit frequency table --
    GFC_V3_STATUS_M_GEM_THROTTLE        = 10077
    GFC_V3_STATUS_M_GEM_TKR             = 66020
    GFC_V3_STATUS_M_GEM_CALLO           = 16734
    GFC_V3_STATUS_M_GEM_CALHI           = 7364
    GFC_V3_STATUS_M_GEM_CNO             = 1991
    GFC_V3_STATUS_M_ACD_TOP             = 10069
    GFC_V3_STATUS_M_ACD_SIDE            = 22182
    GFC_V3_STATUS_M_ACD_SIDE_FILTER     = 9894
    GFC_V3_STATUS_M_TKR_EQ_1            = 15654
    GFC_V3_STATUS_M_TKR_GE_2            = 21361
    GFC_V3_STATUS_M_RSVD_10             = 0
    GFC_V3_STATUS_M_TKR_LT_2_ELO        = 4253
    GFC_V3_STATUS_M_TKR_SKIRT           = 8
    GFC_V3_STATUS_M_TKR_EQ_0            = 24
    GFC_V3_STATUS_M_TKR_ROW2            = 28
    GFC_V3_STATUS_M_TKR_ROW01           = 49
    GFC_V3_STATUS_M_TKR_TOP             = 207
    GFC_V3_STATUS_M_SIDE                = 101
    GFC_V3_STATUS_M_TOP                 = 170
    GFC_V3_STATUS_M_ZBOTTOM             = 45
    GFC_V3_STATUS_M_ERR_CTB             = 331
    GFC_V3_STATUS_M_SPLASH_1            = 2113
    GFC_V3_STATUS_M_E350_FILTER_TILE    = 32
    GFC_V3_STATUS_M_E0_TILE             = 73
    GFC_V3_STATUS_M_EL0_ETOT_HI         = 3755
    GFC_V3_STATUS_M_EL0_ETOT_LO         = 9706
    GFC_V3_STATUS_M_LO_ENERGY           = 20328
    GFC_V3_STATUS_M_HI_ENERGY           = 3688
    GFC_V3_STATUS_M_SPLASH_0            = 516
    GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
    GFC_V3_STATUS_M_NON_PHYSICS         = 171
    GFC_V3_STATUS_M_VETOED              = 4000
OnboardFilter.M...   INFO -- MIP Filter Status Word bit frequency table --
    MFC_STATUS_M_STAGE_GEM           = 66428
    MFC_STATUS_M_STAGE_ACD           = 0
    MFC_STATUS_M_STAGE_DIR           = 0
    MFC_STATUS_M_STAGE_CAL           = 0
    MFC_STATUS_M_STAGE_XCAL          = 0
    MFC_STATUS_M_MULTI_PKT           = 0
    MFC_STATUS_M_ERR_CAL             = 0
    MFC_STATUS_M_ERR_CTB             = 0
    MFC_STATUS_M_ERR_DIR             = 0
    MFC_STATUS_M_RSVD_09             = 0
    MFC_STATUS_M_RSVD_10             = 0
    MFC_STATUS_M_RSVD_11             = 0
    MFC_STATUS_M_RSVD_12             = 0
    MFC_STATUS_M_RSVD_13             = 0
    MFC_STATUS_M_RSVD_14             = 0
    MFC_STATUS_M_RSVD_15             = 0
    MFC_STATUS_M_RSVD_16             = 0
    MFC_STATUS_M_RSVD_17             = 0
    MFC_STATUS_M_RSVD_18             = 0
    MFC_STATUS_M_RSVD_19             = 0
    MFC_STATUS_M_RSVD_20             = 0
    MFC_STATUS_M_RSVD_21             = 0
    MFC_STATUS_M_RSVD_22             = 0
    MFC_STATUS_M_RSVD_23             = 0
    MFC_STATUS_M_RSVD_24             = 0
    MFC_STATUS_M_RSVD_25             = 0
    MFC_STATUS_M_NO_TKR_ADJ          = 0
    MFC_STATUS_M_LYR_COUNTS          = 0
    MFC_STATUS_M_NO_ACD_TKR          = 63371
    MFC_STATUS_M_GEM_NOTKR           = 501
    MFC_STATUS_M_GEM_CNO             = 2556
    MFC_STATUS_M_VETOED              = 66428
OnboardFilter.H...   INFO -- HIP Filter Status Word bit frequency table --
    HFC_STATUS_M_STAGE_GEM           = 66429
    HFC_STATUS_M_STAGE_DIR           = 0
    HFC_STATUS_M_STAGE_CAL           = 0
    HFC_STATUS_M_STAGE_CAL_ECHK      = 0
    HFC_STATUS_M_STAGE_CAL_LCHK      = 0
    HFC_STATUS_M_MULTI_PKT           = 0
    HFC_STATUS_M_ERR_CAL             = 0
    HFC_STATUS_M_ERR_CTB             = 0
    HFC_STATUS_M_ERR_DIR             = 0
    HFC_STATUS_M_RSVD_09             = 0
    HFC_STATUS_M_RSVD_10             = 0
    HFC_STATUS_M_RSVD_11             = 0
    HFC_STATUS_M_RSVD_12             = 0
    HFC_STATUS_M_RSVD_13             = 0
    HFC_STATUS_M_RSVD_14             = 0
    HFC_STATUS_M_RSVD_15             = 0
    HFC_STATUS_M_RSVD_16             = 0
    HFC_STATUS_M_RSVD_17             = 0
    HFC_STATUS_M_RSVD_18             = 0
    HFC_STATUS_M_RSVD_19             = 0
    HFC_STATUS_M_RSVD_20             = 0
    HFC_STATUS_M_RSVD_21             = 0
    HFC_STATUS_M_RSVD_22             = 0
    HFC_STATUS_M_RSVD_23             = 0
    HFC_STATUS_M_RSVD_24             = 0
    HFC_STATUS_M_RSVD_25             = 0
    HFC_STATUS_M_LYR_ENERGY          = 0
    HFC_STATUS_M_LYR_COUNTS          = 0
    HFC_STATUS_M_GEM_NOTKR           = 0
    HFC_STATUS_M_GEM_NOCALLO         = 75
    HFC_STATUS_M_GEM_NOCNO           = 66354
    HFC_STATUS_M_VETOED              = 66429
OnboardFilter.D...   INFO -- DFC Filter bit frequency table --
    Status Bit                         Value
    DFC_STATUS_M_STAGE_GEM             66429
    Veto Bit Summary
    Trigger Name                           Count
    DFC_STATUS_M_GEM_CLASSES           66429
    DFC_STATUS_M_VETOED                66429
OnboardFilter        INFO Encountered 0 events with no ebf data

17-35-24-gr30

TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
---- --- --- --- --- ---
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events

OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000

OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66428
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 0
MFC_STATUS_M_STAGE_CAL = 0
MFC_STATUS_M_STAGE_XCAL = 0
MFC_STATUS_M_MULTI_PKT = 0
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 0
MFC_STATUS_M_LYR_COUNTS = 0
MFC_STATUS_M_NO_ACD_TKR = 63371
MFC_STATUS_M_GEM_NOTKR = 501
MFC_STATUS_M_GEM_CNO = 2556
MFC_STATUS_M_VETOED = 66428

OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 0
HFC_STATUS_M_STAGE_CAL = 0
HFC_STATUS_M_STAGE_CAL_ECHK = 0
HFC_STATUS_M_STAGE_CAL_LCHK = 0
HFC_STATUS_M_MULTI_PKT = 0
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 0
HFC_STATUS_M_LYR_COUNTS = 0
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 75
HFC_STATUS_M_GEM_NOCNO = 66354
HFC_STATUS_M_VETOED = 66429

OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count

DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429

OnboardFilter INFO Encountered 0 events with no ebf data


  • No labels