For completeness we repeated the digitization step using the same evt file using a CMT RHEL4 opt build GR v17r35p24gr15 which uses OBF B1-1-3 and compared that to an SCons RHEL4 opt build of GR 17-35-24-lp22 also using OBF B1-1-3.

GR 17-35-24-lp22

EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
--- — --- — -- —
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
--- — --- — -- —
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events
OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000
OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66428
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 0
MFC_STATUS_M_STAGE_CAL = 0
MFC_STATUS_M_STAGE_XCAL = 0
MFC_STATUS_M_MULTI_PKT = 0
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 0
MFC_STATUS_M_LYR_COUNTS = 0
MFC_STATUS_M_NO_ACD_TKR = 63371
MFC_STATUS_M_GEM_NOTKR = 501
MFC_STATUS_M_GEM_CNO = 2556
MFC_STATUS_M_VETOED = 66428
OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 0
HFC_STATUS_M_STAGE_CAL = 0
HFC_STATUS_M_STAGE_CAL_ECHK = 0
HFC_STATUS_M_STAGE_CAL_LCHK = 0
HFC_STATUS_M_MULTI_PKT = 0
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 0
HFC_STATUS_M_LYR_COUNTS = 0
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 75
HFC_STATUS_M_GEM_NOCNO = 66354
HFC_STATUS_M_VETOED = 66429
OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count
DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429
OnboardFilter INFO Encountered 0 events with no ebf data

GR v17r35p24gr15 CMT Build 

EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
---- --- --- --- --- ---
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events

OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000

OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66428
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 0
MFC_STATUS_M_STAGE_CAL = 0
MFC_STATUS_M_STAGE_XCAL = 0
MFC_STATUS_M_MULTI_PKT = 0
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 0
MFC_STATUS_M_LYR_COUNTS = 0
MFC_STATUS_M_NO_ACD_TKR = 63371
MFC_STATUS_M_GEM_NOTKR = 501
MFC_STATUS_M_GEM_CNO = 2556
MFC_STATUS_M_VETOED = 66428

OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 0
HFC_STATUS_M_STAGE_CAL = 0
HFC_STATUS_M_STAGE_CAL_ECHK = 0
HFC_STATUS_M_STAGE_CAL_LCHK = 0
HFC_STATUS_M_MULTI_PKT = 0
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 0
HFC_STATUS_M_LYR_COUNTS = 0
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 75
HFC_STATUS_M_GEM_NOCNO = 66354
HFC_STATUS_M_VETOED = 66429

OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count

DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429

OnboardFilter INFO Encountered 0 events with no ebf data
ParticlePropert... INFO Service finalised successfully

GR v15r47p12gr21 

EventSelector INFO Processed 66429 event from a file containing 66429 events
EventLoopMgr INFO No more events in event selection
TriggerAlg INFO Totals triggered/ processed: 66429/66429
bit frequency: all events
value count CNO CALHI CALLO TKR ROI
---- --- --- --- --- ---
0 723 0 0 0 0 0
2 46357 0 0 0 46357 0
3 2279 0 0 0 2279 2279
4 9 0 0 9 0 0
6 7565 0 0 7565 7565 0
7 1997 0 0 1997 1997 1997
12 65 0 65 65 0 0
14 1106 0 1106 1106 1106 0
15 4337 0 4337 4337 4337 4337
18 1 1 0 0 1 0
19 71 71 0 0 71 71
22 1 1 0 1 1 0
23 284 284 0 284 284 284
28 1 1 1 1 0 0
31 1633 1633 1633 1633 1633 1633
---- --- --- --- --- ---
tot: 66429 1991 7142 16998 65631 10601
EbfWriter INFO Wrote 66429 Total Events

OnboardFilter.G... INFO – Gamma Filter Status Word bit frequency table –
GFC_V3_STATUS_M_GEM_THROTTLE = 10077
GFC_V3_STATUS_M_GEM_TKR = 66020
GFC_V3_STATUS_M_GEM_CALLO = 16734
GFC_V3_STATUS_M_GEM_CALHI = 7364
GFC_V3_STATUS_M_GEM_CNO = 1991
GFC_V3_STATUS_M_ACD_TOP = 10069
GFC_V3_STATUS_M_ACD_SIDE = 22182
GFC_V3_STATUS_M_ACD_SIDE_FILTER = 9894
GFC_V3_STATUS_M_TKR_EQ_1 = 15654
GFC_V3_STATUS_M_TKR_GE_2 = 21361
GFC_V3_STATUS_M_RSVD_10 = 0
GFC_V3_STATUS_M_TKR_LT_2_ELO = 4253
GFC_V3_STATUS_M_TKR_SKIRT = 8
GFC_V3_STATUS_M_TKR_EQ_0 = 24
GFC_V3_STATUS_M_TKR_ROW2 = 28
GFC_V3_STATUS_M_TKR_ROW01 = 49
GFC_V3_STATUS_M_TKR_TOP = 207
GFC_V3_STATUS_M_SIDE = 101
GFC_V3_STATUS_M_TOP = 170
GFC_V3_STATUS_M_ZBOTTOM = 45
GFC_V3_STATUS_M_ERR_CTB = 331
GFC_V3_STATUS_M_SPLASH_1 = 2113
GFC_V3_STATUS_M_E350_FILTER_TILE = 32
GFC_V3_STATUS_M_E0_TILE = 73
GFC_V3_STATUS_M_EL0_ETOT_HI = 3755
GFC_V3_STATUS_M_EL0_ETOT_LO = 9706
GFC_V3_STATUS_M_LO_ENERGY = 20328
GFC_V3_STATUS_M_HI_ENERGY = 3688
GFC_V3_STATUS_M_SPLASH_0 = 516
GFC_V3_STATUS_M_NOCALLO_FILTER_TILE = 2245
GFC_V3_STATUS_M_NON_PHYSICS = 171
GFC_V3_STATUS_M_VETOED = 4000

OnboardFilter.M... INFO – MIP Filter Status Word bit frequency table –
MFC_STATUS_M_STAGE_GEM = 66428
MFC_STATUS_M_STAGE_ACD = 0
MFC_STATUS_M_STAGE_DIR = 0
MFC_STATUS_M_STAGE_CAL = 0
MFC_STATUS_M_STAGE_XCAL = 0
MFC_STATUS_M_MULTI_PKT = 0
MFC_STATUS_M_ERR_CAL = 0
MFC_STATUS_M_ERR_CTB = 0
MFC_STATUS_M_ERR_DIR = 0
MFC_STATUS_M_RSVD_09 = 0
MFC_STATUS_M_RSVD_10 = 0
MFC_STATUS_M_RSVD_11 = 0
MFC_STATUS_M_RSVD_12 = 0
MFC_STATUS_M_RSVD_13 = 0
MFC_STATUS_M_RSVD_14 = 0
MFC_STATUS_M_RSVD_15 = 0
MFC_STATUS_M_RSVD_16 = 0
MFC_STATUS_M_RSVD_17 = 0
MFC_STATUS_M_RSVD_18 = 0
MFC_STATUS_M_RSVD_19 = 0
MFC_STATUS_M_RSVD_20 = 0
MFC_STATUS_M_RSVD_21 = 0
MFC_STATUS_M_RSVD_22 = 0
MFC_STATUS_M_RSVD_23 = 0
MFC_STATUS_M_RSVD_24 = 0
MFC_STATUS_M_RSVD_25 = 0
MFC_STATUS_M_NO_TKR_ADJ = 0
MFC_STATUS_M_LYR_COUNTS = 0
MFC_STATUS_M_NO_ACD_TKR = 63371
MFC_STATUS_M_GEM_NOTKR = 501
MFC_STATUS_M_GEM_CNO = 2556
MFC_STATUS_M_VETOED = 66428

OnboardFilter.H... INFO – HIP Filter Status Word bit frequency table –
HFC_STATUS_M_STAGE_GEM = 66429
HFC_STATUS_M_STAGE_DIR = 0
HFC_STATUS_M_STAGE_CAL = 0
HFC_STATUS_M_STAGE_CAL_ECHK = 0
HFC_STATUS_M_STAGE_CAL_LCHK = 0
HFC_STATUS_M_MULTI_PKT = 0
HFC_STATUS_M_ERR_CAL = 0
HFC_STATUS_M_ERR_CTB = 0
HFC_STATUS_M_ERR_DIR = 0
HFC_STATUS_M_RSVD_09 = 0
HFC_STATUS_M_RSVD_10 = 0
HFC_STATUS_M_RSVD_11 = 0
HFC_STATUS_M_RSVD_12 = 0
HFC_STATUS_M_RSVD_13 = 0
HFC_STATUS_M_RSVD_14 = 0
HFC_STATUS_M_RSVD_15 = 0
HFC_STATUS_M_RSVD_16 = 0
HFC_STATUS_M_RSVD_17 = 0
HFC_STATUS_M_RSVD_18 = 0
HFC_STATUS_M_RSVD_19 = 0
HFC_STATUS_M_RSVD_20 = 0
HFC_STATUS_M_RSVD_21 = 0
HFC_STATUS_M_RSVD_22 = 0
HFC_STATUS_M_RSVD_23 = 0
HFC_STATUS_M_RSVD_24 = 0
HFC_STATUS_M_RSVD_25 = 0
HFC_STATUS_M_LYR_ENERGY = 0
HFC_STATUS_M_LYR_COUNTS = 0
HFC_STATUS_M_GEM_NOTKR = 0
HFC_STATUS_M_GEM_NOCALLO = 75
HFC_STATUS_M_GEM_NOCNO = 66354
HFC_STATUS_M_VETOED = 66429

OnboardFilter.D... INFO – DFC Filter bit frequency table –
Status Bit Value
DFC_STATUS_M_STAGE_GEM 66429
Veto Bit Summary
Trigger Name Count

DFC_STATUS_M_GEM_CLASSES 66429
DFC_STATUS_M_VETOED 66429

OnboardFilter INFO Encountered 0 events with no ebf data

  • No labels