Reason for change:
We request to deploy AlarmsCfg-07-01-02 in L1proc. In this new tag we relaxed the limits for the alarms related to the spacecraft altitude.
Test Procedure:
This version of AlarmsCfg has been tested processing locally the monitoring products from a LPA run (42863605).
Rollback procedure:
The package can be rolled back to the previous version by flipping a soft link. Also note that the package is completely independent from any other package running in the pipeline and will not cause a version change of L1Proc.
CCB JIRA:
- SSC-466Getting issue details... STATUS
Details:
from AlarmsCfg/doc/release.notes:
- -Updating alarm limits on Mean_FastMon_SpaceCraft_Altitude:
low warning limit changed from 500 to 480
Relevant threads:https://www-glast.stanford.edu/protected/mail/datamon/4445.html