Linux and RTEMS

0x0 : BOOT_SUCCESS - The operating system has booted and been assigned an IP address
0x1 : BOOT_REBOOTING - The operating system received a DSL reboot request and is rebooting (V1.10.0 and up)
0x2 : BOOT_UPDATING - The operating system received a DSL update request and is updating (V1.10.0 and up)

RTEMS Only

0x8 - 8: BOOT_DSLEXE - dsl exe started
0xc - 12 : BOOT_DSLPREFS - dsl exe preferences loaded
0x10 - 16 : BOOT_STARTSVC - startup services started
0x12 - 18 : BOOT_LINKTRAIN - 10G network phy link training
0x14 - 20 : BOOT_STARTPREFS - startup service preferences loaded
0x18 - 24 : BOOT_APPSVT - application svt installed
0x1a - 26 : BOOT_SYSSVT - system svt installed
0x1e - 30 : BOOT_CFGNAMESPACE - config namespace installed
0x20 - 32 : BOOT_SYSNAMESPACE - system namespace installed
0x24 - 36 : BOOT_APP_SDMOUNT - application sd partition mounted
0x26 - 38 : BOOT_SYS_SDMOUNT - system sd partition mounted
0x28 - 40 : BOOT_SDINIT - sd driver initialized
0x2a - 42 : BOOT_RTEMSLDR - Ldr_Install_Rtems completed
0x2c - 44 : BOOT_DBGINIT - Debug package init completed
0x30 - 48 : BOOT_WRAPPOSTDRVHOOK - __wrap_bsp_postdriver_hook executed
0x34 - 52 : BOOT_POSTDRVHOOK - brd_postdriver_hook executed
0x38 - 56 : BOOT_WRAPPREDRVHOOK - __wrap_bsp_predriver_hook executed
0x3c - 60 :  BOOT_PREDRVHOOK - brd_predriver_hook executed
0x40 - 64 : BOOT_WRAPPRETASKHOOK - __wrap_bsp_pretasking_hook executed
0x44 - 68 : BOOT_PRETASKHOOK - brd_pretasking_hook executed
0x48 - 72 : BOOT_WRAPBSPSTART - __wrap_bsp_start executed
0x4c - 76 : BOOT_BRDSTART - brd_start executed
0x50 - 80 : BOOT_BSPSTARTHOOK1 - bsp_start_hook_1 executed
0x54 - 84 : BOOT_BSPSTARTHOOK0 - bsp_start_hook_0 executed

U-Boot

0xea - 234 : BOOT_OS_HANDOFF - U-boot has transferred control to another operating system
0xee - 238 : BOOT_RCE_READY - U-boot has completed RCE board initialization and is ready to boot an operating system
0xf2 - 242 : BOOT_CM_INIT - The DTM is initializing the network switch driver (DTM only)
0xff - 255 : BOOT_NOT_BOOTED - U-boot has started execution but has not yet initialized RCE board support

 