  • /reg/d/psdm/mec/mecj5515/xtc - data for runs 1-340 taken from December 2, 2015 to January 4,2016.
  • Runs 128, 129 were taken on December 14, 2015

Metrology and geometry

As posted on https://confluence.slac.stanford.edu/display/PSDM/CSPad+alignment#CSPADAlignment-MEC

metrology measurements for MecTargetChamber.0:Cspad.0 was done on

  • 2015-06-08 for quad0 (quads 1 and 2 were not available)
  • 2016-02-16 for quad0-2 (recommended to use for later dates)

In mecj5515 metrology from 2015-06-08 for quad 0 is used also for quads 1 and 2.

Plots

use

  • exp=mecj5515:run=128 for quad0,1
  • exp=mecj5515:run=129 for quad2

Images for cspad and quads 0,1,2 using 2015-06-08 metrology

Images for cspad and quads 0,1,2 using 2015-02-16 metrology

Summary

  • For mecj5515 metrology for quads 1 and 2 is unavailable.
  • metrology from 2015-06-08 for quad 0 is used also for quads 1 and 2.
  • It is not clear if metrology from 2015-02-16 works better.

 

 

 

 