Set LCLS2 environment
Data diagnostic commands
Commands below can be run in lcls2 environment on psana nodes having access to experimental data under /cds/data/psdm/<INSTRUMENT>/<EXPERIMENT>/xtc/*.
Command examples are valid for code release ps-4.5.5, default version on 2021-10-25. They may evolve in other releases. Use "-h" option to find latest option of each command.
datinfo
USAGE: datinfo -d <detector> -e <experiment> -r <run-number(s)> [kwargs] COMMAND EXAMPLES: datinfo -d epixquad -e ueddaq02 -r 27 -td -L DEBUG datinfo -d epixquad -e ueddaq02 -r 30-82 <--- DOES NOT WORK - missconfigured datinfo -d epixquad -e ueddaq02 -r 83 <--- dark datinfo -d epixquad -e ueddaq02 -r 84 <--- PARTLY WORKS charge injection datinfo -d epixquad -f /cds/data/psdm/ued/ueddaq02/xtc/ueddaq02-r0065-s001-c000.xtc2 datinfo -d epixquad -f /cds/data/psdm/ued/ueddaq02/xtc/ueddaq02-r0086-s001-c000.xtc2 datinfo -d tmoopal -e tmoc00118 -r 123 -td HELP: datinfo -h
epix10ka_raw_calib_image
USAGE: epix10ka_raw_calib_image [test-name] [optional-arguments] where test-name: raw - test_raw W/O GRAPHICS calib - test_calib W/O GRAPHICS [image] - test_image WITH GRAPHICS - optional default mask, peds, rms, status, gain, z/y/xcoords - test_single_image WITH GRAPHICS COMMAND EXAMPLES: epix10ka_raw_calib_image raw -e ueddaq02 -d epixquad -r66 # raw epix10ka_raw_calib_image calib -e ueddaq02 -d epixquad -r66 # calib epix10ka_raw_calib_image mask -e ueddaq02 -d epixquad -r66 # mask epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r66 -N1000 # image epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r108 -N1 -S grind epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r140 -N100 -M2 -S calibcm8 epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r140 -N100 -M2 -S calibcm8 -o img-ueddaq02-epixquad-r140-ev0002-cm8-7-100-10.png -N3 epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r211 -N1 -M0 -Speds -g0 # - plot pedestals for gain group 0/FH epix10ka_raw_calib_image -e ueddaq02 -d epixquad -r211 -N100 -Sraw-peds -M2 -g2 # - plot calib[step=2] - pedestals[gain group 2] epix10ka_raw_calib_image -e rixx45619 -d epixhr -r118 --gramin 1 --gramax 32000 -Sraw epix10ka_raw_calib_image -e rixx45619 -d epixhr -r118 --gramin 1 --gramax 32000 -Speds -g0 epix10ka_raw_calib_image -e rixx45619 -d epixhr -r118 --gramin -100 --gramax 100 -Sraw-peds -g0 epix10ka_raw_calib_image -e rixx45619 -d epixhr -r119 -Scalib epix10ka_raw_calib_image -e rixx45619 -d epixhr -r119 -Sones epix10ka_raw_calib_image -e rixx45619 -d epixhr -N10000 -J200 --gramin 0 --gramax 10 -Sgrind epix10ka_raw_calib_image mask -e rixx45619 -d epixhr -r119 epix10ka_raw_calib_image peds -e rixx45619 -d epixhr -r119 -g1 epix10ka_raw_calib_image gains -e rixx45619 -d epixhr -r119 -g1 epix10ka_raw_calib_image xcoords -e rixx45619 -d epixhr -r119 --cframe=1 HELP: epix10ka_raw_calib_image -h
epix10ka_calib_components
USAGE: epix10ka_calib_components -r554 -t1 epix10ka_calib_components -e ueddaq02 -d epixquad -r554 -t1 -t, --tname - test number: 1 - segment numeration 2 - gain range index 3 - gain, ADU/keV 4 - pedestals 5 - rms 6 - raw 7 - raw-peds 8 - (raw-peds)/gain, keV 9 - calib, keV 10 - status 11 - gain factor = 1/gain, keV/ADU ---- 21 - run 401 two-threshold selection issue 22 - (raw-peds)/gain, keV hot - specific isuue test 23 - (raw-peds)/gain, keV cold - specific isuue test epix10ka_calib_components - test per-event components of the det.raw.calib method HELP: epix10ka_calib_components -h
References
Overview
Content Tools