This page is meant to serve as a space that lists the current IMS and dumb motor stages currently deployed in LCLS-I. The names listed here are also the names associated with the parameter manager, a tool used for setting up these stages for use in experiments, and should be put in the "Stage Identifier" tab on the experiment questionnaire. Unless noted otherwise, these stages are outfitted with 2-phase stepper motors. For all stages, there should be a descriptive label affixed to it.
Stage Name | Specifications | # of motors/axis | Parameter Manager current and Future Config Name | Configuration Location | In stock? | Tested? |
---|---|---|---|---|---|---|
Huber Goniometer Head1003-MS | x | huber_gon_head_1003-MS_x/Huberhead_xy | have/in pmgr(xcsusr)/not tested | |||
y | huber_gon_head_1003-MS_y/Huberhead_xy | have/in pmgr(xcsusr)/not tested | ||||
ry | huber_gon_head_1003-MS_ry/Huberhead_rot | have/in pmgr(xcsusr)/not tested | ||||
rx | huber_gon_head_1003-MS_rx/Huberhead_rot | have/in pmgr(xcsusr)/not tested | ||||
Huber 408-110766 | huber_408.01 | have/in pmgr(xppusr)/not tested | ||||
AT-C8-HV (JJ Slits) | Horizontal Gap | JJxray_gap | in pmgr(usr)/not tested | |||
Vertical Gap | ||||||
Horizontal Offset | JJxray_offset | in pmgr(usr)/not tested | ||||
Vertical Offset | ||||||
LINK | 1 | Micronix_VT50-55mm | in pmgr(xcsusr/usr)/not tested | |||
1 | Micronix_VT50-100mm | in pmgr(xcsusr/usr)/not tested | ||||
?? | OptiquePeter_RVTS65 | in pmgr(usr)/not tested | ||||
LINK | 1 | Kohzu_RA10A-W01 | have/not in pmgr/not tested | XCS | ||
LINK | 1 | Kohzu_ZA10A-W201 | in pmgr(usr) | XCS | Yes | |
Kohzu XA07A-R103 | LINK | 1 | Kohzu_XA07A-R103 | have/not in pmgr/not tested | XCS | |
LINK | 1 | Kohzu_SA05A-R2T01 | have/not in pmgr/not tested | XCS | ||
Kohzu RA10A-W-4T | Unlisted | Kohzu_RA10A-W-4T | have/in pmgr(usr/xcsusr)/not tested | XCS | ||
Kohzu_RA10A-W-4T_GR40 | not in pmgr/not tested | |||||
Unlisted | Kohzu_SA07A-R2W | in pmgr(xppusr)/not tested | ||||
1 | Kohzu_SA07A-R2M | have/not in pmgr/not tested | ||||
LINK | 1 | Kohzu_XA07A-R102 | in pmgr(usr)/not tested | |||
LINK | Kohzu_SA05A-R2M01 | in pmgr(usr) | XCS | Yes | ||
LINK | 1 | Kohzu_RA10A-W | in pmgr/not tested | |||
Kohzu_RA10A-T | have/not in pmgr/not tested | XPP | ||||
LINK | 1 | Kohzu_XA07A-R202 | in pmgr/not tested | |||
Unlisted | Kohzu_XA07A-R2 | have/in pmgr(usr/xcsusr)/not tested | XPP | |||
LINK | 1 | Kohzu_XA10A-L1 | in pmgr(xppusr)/not tested | |||
LINK | 1 | Kohzu_XA10A-R1 | have/in pmgr(xppusr)/not tested | XPP | Yes | |
LINK | 1 | Kohzu_XA10A-R101 | have/in pmgr(usr/xcsusr)/not tested | XCS | ||
LINK | 1 | Kohzu_XA10A-R201 | in pmgr(usr)/not tested | Yes | ||
LINK | 1 | Kohzu_ZA05A-W1 | have/in pmgr(usr/xcsusr)/not tested | |||
LINK | 1 | Kohzu_ZA07A-R3S | have/in pmgr(usr/xcsusr)/not tested | XPP | Yes | |
LINK | 1 | Kohzu_ZA10A-32F | have/in pmgr(usr/xcsusr)/not tested | XPP | Yes | |
LINK | 1 | Kohzu_ZA10A-W201 | have/in pmgr(usr)/not tested | XPP | Yes | |
LINK | 1 | Kohzu_ZA10A-W2C-02 | in pmgr(usr/xcsusr/xppusr)/not tested | |||
LINK | 1 | Kohzu_SA07A-RT01 | have/in pmgr(usr/xcsusr)/not tested | |||
LINK | 1 | Kohzu_RA07A-W | in pmgr(usr/xcsusr)/not tested | |||
1 | Kohzu_XA05A-L201 | xppusr | ||||
LINK | 1 | Kohzu_MVRA16A-WH-BM | usr/cyro_chamber | XPP | Yes | |
LINK | 1 | Kohzu_MVSA10-RB-1P | usr/cyro_chamber | XPP | Yes | |
LINK | 1 | Kohzu_MVSA10-RM-R-1A | usr/cyro_chamber | XPP | Yes | |
LINK | 1 | Kohzu_MVXA07A-L202 | usr/cyro_chamber | XPP | Yes | |
LINK | 1 | Kohzu_MVXA07A-R103 | usr/cyro_chamber | XPP | Yes | |
LINK? | 1 | Kohzu_MVZA07A-W2C01-1B | usr/cyro_chamber | XPP | Yes | |
LINK? | 1 | Kohzu_MVZA10A-W2-R-1A | usr/cyro_chamber | XPP | Yes | |
Micos_6237 | LINK | 1 | Micos_6237 | usr/Micos_6237 | MEC | Yes |