Al foils

materialthicknessformquantity / conditionpurchase order needs
Al0.65 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al

0.8 µm

foillow / none99%, light-tight, ~ 0.01 m2, x1
Al1.2 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al1.8 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al2 µmfoil-no
Al2.5 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al3 µmfoil-no
Al4.0 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al7.0 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al10 µmfoil(100x100mm) x3no
Al12.5 µmfoil-no
Al12.5 µmfoillow / none99%, light-tight, ~ 0.01 m2, x1
Al20 µmfoilsmall piecesno
Al25 µmfoilmany foilsno
Al30 µmfoil-no
Al50 µmfoil(100x100mm) x5no
Al50 µmfoilscrapsno
Al100 µmfoilx3no
Al100 µmfoilscraps99%, light-tight, ~ 0.1 m2, x2

Plastics

materialthicknessformquantity / conditionpurchase order needs
black kapton25 µmfoil-no
amber kapton130 µm ± 10 µmfoil(300x300mm) x1.75no
LDPE125 µmfoila few piecesno
polycarbonate125 µmfoillarge dimensionsno
PET clear100 µmfoil(100x100mm) x5no

Spectrometer calibration samples

materialthicknessformquantity / conditionpurchase order needs
Ti12.7 µmfoil99.8% (90x90mm)no
Fe50 µmfoil(25x25mm) x2 partly usedno
Co25 µmfoil-no
Ni12.5 µmfoilsmall piecesno
Cu25 µmfoil(25x25mm)no
Zn25 µmfoil(25x25mm)no
Tb100 µmfoil(25x25mm)no

3d transition metal bag

materialthicknessformquantity / conditionpurchase order needs
Sc12.5 µmfoil(25x25mm) x1no
Ti200 µmfoil-no
V2 µmfoilx1no
Cr2 µmfoix4no
Cr20 µmfoil-no
Mn2 µmon polyester foil(25x25mm) x4no
Mn10 µmfoilscrapsno
Fe5 µmfoil-no
Fe6 µmfoil-no
Fe12.5 µmfoil-no
Fe25 µmfoil-no
Fe100 µmfoil-no
Fe150 µmfoil-

no

Co2 µmfoilx4no
Ni2 µmfoil(25x25mm) x3no
Ni2 µmfoil-no
Ni12.5 µmfoilx3no
Ni25 µmfoilx2no
Cu2 µmfoil-no
Cu5 µmfoilx2no
Cu25 µmfoil-no
Cu50 µmfoil-no

Magnesium bag

materialthicknessformquantity / conditionpurchase order needs
Mg7.5 µmfoil(50x50mm) x2no
Mg7.5 µmfoil-no
Mg10 µmfoil-no
Mg25 µmfoilx3no
Mg50 µmfoil-no

Copper bag

materialthicknessformquantity / conditionpurchase order needs
Cu10 µmfoil(50x50mm) x2no
Cu38 µmfoil-no
Cu25 µmfoilx2no
Cu50 µmfoil-no
Cu100 µmfoil-no
Cu1.0 mmfoil-no
Cu-thick plate-no

High-Z

materialthicknessformquantity / conditionpurchase order needs
Ag10 µmfoil-no
Ag12.5 µmfoil-no
Sn5 µm

foil

-no
Sn6 µmfoil-no
Sn15 µmfoilEmptyyes
W4 µmfoil-no
W5 µmfoil(25x25mm)no
Au2 µm

foil

-no
Au5 µmfoil(25x25mm)no
Au10 µmfoil(100x100mm)no
Au100 µmfoil-no
Bi2.5 µmfoil-no

Alloys bag

materialthicknessformquantity / conditionpurchase order needs
Mg96/Al3/Zn1250 µmfoil-no
Al95/Mg530 µmfoil-no
stainless steel Fe/Cr18/Ni105 µmfoil-no

Miscellaneous

materialthicknessformquantity / conditionpurchase order needs
C vitreous200 µmfoil-no
alumina Al2O3150 µmfoil-no
alumina Al2O3250 µmfoil-no
aluminized mylar-disc-no
Ti2.5 µmfoil-no
Ti250 µmfoil-no
Ti500 µmfoil-no
V25 µmfoilmany foilsno
Fe25 µmroll-no
Fe50 µmdiscø 6 mmno
  • No labels