On Analog boards
- Quad Analog-BRD:
Design | Ver | PCB # | LDO | Supply/Net | TP# | Sheet | Item(s) | To | State | (1)Current draw[mA] | Problem.......................................................................... | Note(s) |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Quad | C00 | LT3086EFE | A0+2_5V | See no sense load to AGND | 0 | Possibly... no minimum load resistance | See Small | |||||
A0+2_5V (sheet 18: ASIC_APWR) | 18 | R255 | DET_GND → R364 (0Ohm) → AGND | NO LOAD! | ||||||||
Quad | C01 | VR3 & VR4 | LT3086EFE | VOUT (A0+2_5V) | 9 | See no sense load to AGND | See Small | |||||
R10 & R11 (330 Ohm) | I_MON = I_OUT/1000 resistor for VR3 & VR4 → I_OUT = 1000*I_MON = (1000/330)*V_MON | |||||||||||
ASIC_ANA_EN | 7 | R1 | ASIC_ANA_EN → R1 (10kOhm) → AGND | LDO physically off at bootup | ||||||||
A0+2_5V | 13 | 7 | ||||||||||
A0+2_5V (sheet 19: ASIC_APWR) | 19 | R264 | DET_GND → R364 (0Ohm) → AGND | NO LOAD! | 0 | Possibly... no minimum load resistance | ||||||
A1+2_5V | ||||||||||||
A2+2_5V | ||||||||||||
A3+2_5V | ||||||||||||
Quad | C01B | VR14 | LT3086 | VOUT (D0+2_5V) | 16 | |||||||
R36 (330 Ohm) | I_MON = I_OUT/1000 resistor for VR3 & VR4 → I_OUT = 1000*I_MON = (1000/330)*V_MON | |||||||||||
D0+2_5V | 11 | 7 | ||||||||||
D0+2_5V (sheet 19: ASIC_DPWR) | 19 | NO LOAD! | 0 |
(1) Without asic load added
On Digital boards
- Quad Digital-BRD:
Testing Mods
- PC_261_100_86_C01
- PC_261_100_85_C01