Toroid Electronics Meeting Minutes
June 12, 2006
Electronics/Triggering Discussion
^
Contents
Unknown macro: {maketoc}
^
Attendees:
John Dusatko |
Mike Browne |
Stephen Norum |
Michael Cecere |
Agenda:
- Analog Electronics
- Trigger Generation
Presentation Materials:
Analog Electronics and Triggering, M. Cecere
(PPT Format)
Minutes:
- Discussed Analog Electronics Design
- Is the new toroid polarity being specified? will look into with Tim and Steve
- Need to be careful about headroom (top and bottom) in single supply signal chain
- Use NPO ceramic caps for integration, S/H
- Configuration, can use a DB header, or even jumpers on the main board itself
- Discussed Triggering requirements and generation
- John will handle timing CPLD. Yeah!
- Ron's PAD board will work,
- he can make extras easy, we need two + spare
- his software has a diagnostic mode where the whole waveform is transferred
- i generated various documents for PDR and other purposes,
- in my v: drive users directory
Action Items:
- M. Cecere: Adjust circuit as described above
- M. Cecere: Develop Trigger Generation Scheme with John
- M. Cecere: Need ICD and Test Plan
- M. Cecere: Determine handshaking scheme for IOC and MPS
- M. Cecere: Add Mechnical Box design to timeline
- M. Cecere: Add fast digitizer coding, and coder, to timeline