For the anotated traceroutes see here Routing from UNIMAS to S. E. Asia

Target

Address

Malaysian State

Hops

Min RTT at end (ms)

ASNs

6th hop

Anomalies

www.myren.net.my

203.80.16.120

Kuala Lumpur

11

24

MYREN

MYREN

 

www.um.edu.my

202.185.111.194

Kuala Lumpur*

14

43

MYREN, Jaring

Jaring

 

www.umt.edu.my

58.26.189.68

Terenggaru

12

48

MYREN

MYREN

 

www.upsi.edu.my

202.190.201.62

Perak*

13

24

TM, Jaring

Jaring

 

www.upnm.edu.my

1.9.21.6

 

11

33

MYREN, Jaring

MYREN

 

www.usim.edu.my

58.26.99.98

Negari Sembilan*

12

30

MYREN, Jaring

MYREN

 

www.unisza.edu.my

161.142.148.23

Terenggaru*

12

42

MYREN, Jaring

MYREN

 

www.utem.edu.my

210.48.157.23

Melaka*

19

92

MYREN, Jaring, TM

MYREN

 

www.utm.my

161.139.193.85

Kuala Lumpur*

> 12

31

Jaring, MYREN

Jaring

 

www.universitycollegeshahputra.edu.my

199.27.134.51

 

10

29

Jaring, TM, C&W, PACNET

Jaring, TM

Singapore

www.utp.edu.m

203.135.191.100

Perak*

11

33

MYREN, Jaring

MYREN

 

www.qiup.edu.my

103.6.196.75

 

10

21

TM, Jaring

TM

mschosting

www.allianzeunicollege.edu.my

110.4.41.15

Penang*

10

33

TM, Jaring

TM

mschosting

www.newinti.edu.my

124.150.142.118

 

10

25

TM, Jaring

TM

hop 8 webserver.myix.gov.my

www.mmu.edu.my

203.106.61.79

Selangor*

14

42

MYREN

MYREN

 

www.unikl.edu.my

113.23.141.10

 

15

33

TM, Jaring

TM

 

www.utar.edu.my

58.27.19.137

 

9

33

TM, Jaring, Extreme Broadband

TM

 

www.mahsa.edu.my 

175.139.189.25

 

9

38

TM, Jaring

TM

 

www.miu.edu.my 

220.226.189.71

Selangor*

13

362

TM, Tinet , flag , Reliance

TM

Route via London, Ireland, India

www.aiu.edu.my 

110.4.45.135

Kedah*

10

37

TM, Jaring, mschosting

TM

mschosting

www.btu.upm.edu.my

119.40.116.240

Serawak*

26

71

MYREN, Jaring

MYREN

Lot of hops for not a long way

www.maxis.com.my 

202.75.129.146

 

12

25

TM, Jaring, maxis.myix.gov.my

TM

maxis.myix.gov.my

www.celcom.com.my

203.82.70.227

 

14

40

TM, Jaring, celcom.myix.gov.my

TM

celcom.myix.gov.my

shinjiru.com.my 

111.90.143.33

 

11

21

TM, globaltransit-my.myix.gov.my (218.100.44.67), Jaring

TM

globaltransit-my.myix.gov.my (218.100.44.67)

datakl.com 

210.48.148.222

 

10

43

TM, Jaring

TM

 

emerge.com.my 

210.48.155.230

 

17

58

TM, Jaring

TM

 

* See the measurement of loss, jitter and average RTT from SLAC below:

SLAC to Malaysian Hosts Nov. 2012

UNIMAS to Malaysian Hosts Dec, 2012

Spreadsheet

Spreadsheet

Notes

  • ASN = Autonomous System Number
  • TM  = Telekom Malaysia Berhad
  • myix.gov.my is the Malaysia Internet eXchange
  • The 6th hop is where the traffic is handed over to the ISP.
  • >n means the target host never responded, n is the last hop recorded
  • The min RTT is the minimum of the 3 RTTs measured at each hop.
  • mschosting AKA ExaBytes cloud, looks like the end host may be at cloud service provider rather than the University site. It also appears that mschosting.com name is up or sale.
  • The routing is very strange for www.miu.edu.my. This leads to long RTTs. I believe the traceroutes were made in mid to late December 2012. If so,  they are not reflected in the UNIMAS to MIU pingtable.pl results (see below). Maybe the routes between www.miu.edu.my and pinger.uniumas.my and the host used to make the traceroute measurements are different. This bears fruther investigation.
  • Only 7 out of 25 Malaysian targets use MYREN as their initial ISP. how come? Is Jaring or TM part of MYREN or vice versa.
  • What is the relationship between MYREN, TM and Jaring (in December 2006, the Ministry of Finance of Malaysia officially took over JARING from MIMOS Berhad)

The 2010 map of MYREN seen below may help in understanding the routing. However, the UNIMAS links is here reported at 10Mbps, whereas it is 100Mbps. Also Sabah, Bintulu, Sibu don't show up in the map.

Fibre Optic cables

Sacofa (Sarawak Common Communications Facilities) owns & operates an extensive on-land fibre network within Sarawak as well as an optical fibre submarine cable system connecting Sarawak and Peninsular Malaysia. They have five Operation & Maintenance Centres in Kuching, Sibu, Bintulu, Miri & Mersing. More

There is (2011) a proposed link between Sarawak’s capital Kuching and Indonesia’s Pontianak . The Government Linked Company (GLC) of Sarcofa ,which celebrates 10 years in 2011, enjoys fibre network connectivity with Brunei and an underwater cable system to Mersing, Johor on the west coast of peninsular Malaysia.

The submarine Fiber Optic Cable which provide backbone connectivity between Labuan to Sabah, Sarawak and Peninsular Malaysia has a total bandwith of 110Gbps. Two ground satellites which facilitate as a restoration during submarine cable failure. Labuan is connected to 23 countries via an International Toll Free Services. More.

There is also a list of completed towers available.

  • No labels