Traceroutes from unimas.my measured Dec 30, 2012

Malaysian targets

traceroute to www.myren.net.my (203.80.16.120), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.429 ms 0.471 ms 0.530 ms
2 10.64.0.1 (10.64.0.1) 0.416 ms 0.503 ms 0.558 ms
3 10.15.0.17 (10.15.0.17) 20.707 ms 20.761 ms 20.814 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.140 ms 1.147 ms 1.133 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.611 ms 1.751 ms 1.774 ms #Still in Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.602 ms 20.872 ms 20.853 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 36.035 ms gi0-1-1-0.kch95.jaring.my (61.6.47.33) 9.211 ms f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 36.044 ms
8 ge0-2-0-4-mea95.jaring.my (61.6.97.205) 49.128 ms 203.80.22.161 (203.80.22.161) 39.981 ms 37.031 ms #Jaring is an ISP in Malaysia based in Technology Park Malaysia (TPM), a science park located in Bukit Jalil, Kuala Lumpur,
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 38.062 ms 39.127 ms 38.113 ms
10 gi0-0-0-0-cbj-pe01-v4.myren.net.my (203.80.23.2) 38.018 ms 37.810 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 56.682 ms
11 www.myren.net.my (203.80.16.120) 23.199 ms 24.514 ms 36.527 ms #MYREN is based in Technology Park Malaysia (TPM), a science park located in Bukit Jalil, Kuala Lumpur

ISPs MYREN

=========================================================

traceroute to www.um.edu.my (202.185.111.194), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.391 ms 0.433 ms 0.497 ms
2 10.64.0.1 (10.64.0.1) 0.417 ms 0.489 ms 0.548 ms
3 10.15.0.17 (10.15.0.17) 0.466 ms 0.522 ms 0.559 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.074 ms 1.074 ms 1.171 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.583 ms 1.584 ms 1.580 ms
6 161.142.6.205 (161.142.6.205 Jaring) 7.999 ms 7.562 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 24.896 ms #Penang?
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 27.503 ms 25.158 ms 37.965 ms
8 203.80.22.161 (203.80.22.161) 41.384 ms 39.743 ms 25.570 ms
9 f0-2-0-um-pe01-v4.myren.net.my (203.80.23.74) 37.772 ms 38.251 ms pos0-3-0-1.mlk95 (61.6.17.45) 52.677 ms #Penang?
10 * pos0-2-0-0.drc96.jaring.my (161.142.25.85) 54.624 ms *
11 161.142.24.130 (161.142.24.130) 71.626 ms 72.251 ms 72.161 ms
12 * * *
13 * * pos0-3-0-0.pld95.jaring.my (161.142.23.186) 56.470 ms
14 booksurvey.um.edu.my (202.185.111.194) 43.218 ms 161.142.23.190 (161.142.23.190) 54.073 ms 54.656 ms

MYREN & Jaring are the ISPs
=========================================================

traceroute to www.umt.edu.my (58.26.189.68), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.332 ms 0.364 ms 0.429 ms
2 10.64.0.1 (10.64.0.1) 0.411 ms 0.462 ms 0.519 ms
3 10.15.0.17 (10.15.0.17) 15.700 ms 15.768 ms 15.828 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.952 ms 1.014 ms 1.127 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.125 ms 1.613 ms 1.595 ms # Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.630 ms 20.654 ms 20.675 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 58.680 ms 48.188 ms 57.873 ms
8 203.80.22.161 (203.80.22.161) 49.658 ms 60.498 ms 48.190 ms
9 pos0-3-0-1.mlk95 (61.6.17.45) 51.612 ms 51.576 ms pos0-0-0-1-ump-p-v4.myren.net.my (203.80.22.154) 46.529 ms #Malaka?
10 f0-2-0-umt-pe01-v4.myren.net.my (203.80.23.178) 58.414 ms 58.231 ms 58.202 ms #Penang?
11 f5-6-umt-ce-v4.myren.net.my (203.80.19.74) 38.024 ms 37.677 ms 37.673 ms
12 58.26.189.68 (58.26.189.68) 48.582 ms 48.833 ms 48.517 ms

MYREN is the ISP
=========================================================

traceroute to www.upsi.edu.my (202.190.201.62), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.330 ms 0.368 ms 0.419 ms
2 10.64.0.1 (10.64.0.1) 0.451 ms 0.514 ms 0.565 ms
3 10.15.0.17 (10.15.0.17) 0.702 ms 0.762 ms 0.817 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.207 ms 1.075 ms 1.199 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.277 ms 1.249 ms 1.178 ms # Kuching
6 161.142.6.205 (161.142.6.205) 8.184 ms 8.305 ms 58.26.240.61 (58.26.240.61) 1.922 ms # Jaring, Kuching
7 * * *
8 58.27.101.130 (58.27.101.130) 23.199 ms 24.291 ms 33.391 ms #Telecom Malaysia
9 te0-2-0-0.bkj95.jaring.my (61.6.51.17) 40.387 ms pos0-3-0-1.mlk95 (61.6.17.45) 51.477 ms 50.907 ms # Bukit Jalal, Malaka?
10 g0-0-0-3.upi15.jaring.my (161.142.24.22) 36.640 ms 34.276 ms 36.479 ms
11 61.6.13.206 (61.6.13.206) 35.847 ms 35.843 ms 33.974 ms
12 g0-0-0-3.upi15.jaring.my (161.142.24.22) 54.784 ms 202.190.201.52 (202.190.201.52) 36.873 ms 39.427 ms
13 202.190.201.62 (202.190.201.62) 24.118 ms 24.280 ms 33.073 ms

Jaring and TM (Telekom Malaysia Berhad) are ISPs
=========================================================

traceroute to www.upnm.edu.my (1.9.21.6), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.365 ms 0.399 ms 0.456 ms
2 10.64.0.1 (10.64.0.1) 0.453 ms 0.509 ms 0.569 ms
3 10.15.0.17 (10.15.0.17) 0.469 ms 0.513 ms 0.565 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.093 ms 1.092 ms 1.160 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.569 ms 1.574 ms 1.560 ms #Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.245 ms 161.142.6.205 (161.142.6.205) 7.600 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 20.624 ms #Penang
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 9.066 ms f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 38.627 ms 38.003 ms
8 203.80.22.161 (203.80.22.161) 25.724 ms 26.202 ms 36.505 ms
9 f0-2-0-upnm-pe01-v4.myren.net.my (203.80.23.110) 37.212 ms 37.464 ms pos0-3-0-1.mlk95 (61.6.17.45) 51.687 ms
10 203.80.19.86 (203.80.19.86) 35.183 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 55.241 ms 203.80.19.86 (203.80.19.86) 34.459 ms
11 1.9.21.6 (1.9.21.6) 34.406 ms 37.144 ms 33.267 ms

MYREN and Jaring are ISPs
=========================================================

traceroute to www.usim.edu.my (58.26.99.98), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 1.987 ms 2.028 ms 2.078 ms
2 10.64.0.1 (10.64.0.1) 0.394 ms 0.477 ms 0.524 ms
3 10.15.0.17 (10.15.0.17) 0.448 ms 0.483 ms 0.539 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.239 ms 1.237 ms 1.213 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.596 ms 1-subnet87.unimas.my (161.142.87.1) 1.263 ms 1-subnet236.unimas.my (49.50.236.1) 1.524 ms # Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.373 ms 21.065 ms 20.999 ms
7 * * *
8 ge0-2-0-4-mea95.jaring.my (61.6.97.205) 50.205 ms 49.577 ms *
9 * * *
10 * * *
11 203.80.19.98 (203.80.19.98) 46.155 ms 45.018 ms 58.27.101.129 (58.27.101.129) 92.060 ms #MYREN
12 58.26.99.98 (58.26.99.98) 31.856 ms 43.017 ms 29.614 ms

MYREN and Jaring are ISPs
=========================================================

traceroute to www.unisza.edu.my (161.142.148.23), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.342 ms 0.382 ms 0.431 ms
2 10.64.0.1 (10.64.0.1) 0.567 ms 0.638 ms 0.712 ms
3 10.15.0.17 (10.15.0.17) 0.547 ms 0.543 ms 0.609 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.250 ms 1.227 ms 1.228 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.437 ms 1.437 ms 1.435 ms #Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 22.264 ms 21.600 ms 161.142.6.205 (161.142.6.205) 7.741 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 61.538 ms 56.950 ms gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.349 ms
8 203.80.22.161 (203.80.22.161) 59.104 ms 49.069 ms 60.209 ms
9 pos0-0-0-1-ump-p-v4.myren.net.my (203.80.22.154) 46.873 ms 48.976 ms 46.884 ms
10 f0-2-0-unisz-pe01-v4.myren.net.my (203.80.23.170) 54.428 ms 54.535 ms 54.509 ms
11 61.6.9.114 (61.6.9.114) 71.868 ms f0-3-0-udm-ce-v4.myren.net.my (203.80.19.78) 43.989 ms 43.668 ms
12 www.unisza.edu.my (161.142.148.23) 42.925 ms 53.668 ms 61.6.50.45 (61.6.50.45) 72.050 ms

MYREN and Jaring are the ISPs
=========================================================

traceroute to www.utem.edu.my (210.48.157.23), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.352 ms 0.395 ms 0.445 ms
2 10.64.0.1 (10.64.0.1) 0.523 ms 0.592 ms 0.662 ms
3 10.15.0.17 (10.15.0.17) 0.490 ms 0.529 ms 0.581 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.133 ms 1.197 ms 1.109 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.310 ms 1.295 ms 1.299 ms #Kuching
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.291 ms 21.021 ms 21.399 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 52.500 ms 48.242 ms 47.594 ms
8 ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.513 ms 203.80.22.161 (203.80.22.161) 53.275 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.555 ms
9 pos0-0-0-1-utm-p-v4.myren.net.my (203.80.22.150) 36.328 ms 52.066 ms 35.714 ms
10 f0-2-0-utem-pe01-v4.myren.net.my (203.80.23.158) 33.113 ms 33.166 ms 33.120 ms
11 * * *
12 * * *
13 * * *
14 * * *
15 * * *
16 * * 202.71.96.206 (202.71.96.206) 56.065 ms #TM
17 * * *
18 * * *
19 210.48.157.23 (210.48.157.23) 92.473 ms * *

MYREN, Jaring, TM are ISPs
=========================================================

traceroute to www.utm.my (161.139.193.85), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.371 ms 0.414 ms 0.471 ms
2 10.64.0.1 (10.64.0.1) 0.452 ms 0.532 ms 0.584 ms
3 10.15.0.17 (10.15.0.17) 0.446 ms 0.511 ms 0.561 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.139 ms 1.213 ms 1.315 ms
5 1-subnet87.unimas.my (161.142.87.1) 1.474 ms 1-subnet236.unimas.my (49.50.236.1) 1.567 ms 1.362 ms
6 161.142.6.205 (161.142.6.205) 7.844 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 20.993 ms 20.965 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 35.333 ms 44.442 ms 31.767 ms
8 203.80.22.161 (203.80.22.161) 31.702 ms 31.808 ms 31.410 ms
9 pos0-3-0-1.mlk95 (61.6.17.45) 51.620 ms pos0-0-0-1-utm-p-v4.myren.net.my (203.80.22.150 MYREN) 43.532 ms pos0-3-0-1.mlk95 (61.6.17.45 Jaring) 51.128 ms
10 f0-2-0-utm-pe01-v4.myren.net.my (203.80.23.154) 39.633 ms 40.426 ms 39.606 ms
11 161.139.244.2 (161.139.244.2) 28.471 ms 28.969 ms 28.004 ms
12 te0-0-0-0.bkj96.jaring.my (61.6.10.2) 56.366 ms utm.my (161.139.193.85) 30.471 ms te0-0-0-0.bkj96.jaring.my (61.6.10.2) 57.295 ms

MYREN and Jaring are ISPs
=========================================================

traceroute to www.universitycollegeshahputra.edu.my (199.27.134.51), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.333 ms 0.367 ms 0.416 ms
2 10.64.0.1 (10.64.0.1) 0.490 ms 0.553 ms 0.612 ms
3 10.15.0.17 (10.15.0.17) 0.470 ms 0.533 ms 0.591 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.920 ms 1.007 ms 0.963 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.605 ms 1.591 ms 1.574 ms
6 161.142.6.205 (161.142.6.205 Jaring) 7.836 ms 58.26.240.61 (58.26.240.61 TM) 1.725 ms 1.709 ms
7 * * *
8 TM.gw3.sin3.asianetcom.net (203.192.169.25 PACNET) 26.222 ms E1-11-0-5.gw1.sin1.asianetcom.net (203.192.169.37) 26.289 ms PEER-ANC-4260.asianetcom.net (203.192.169.25) 26.371 ms #PACNET
9 so-0-1-2-ccr1.sng.cw.net (203.169.57.153 Cable & Wireless) 143.166 ms CDF-0006.asianetcom.net (203.192.154.6 PACNET) 43.093 ms so-0-1-2-ccr1.sng.cw.net (203.169.57.153) 142.395 ms #Singapore? C&W and PACNET
10 cf-199-27-134-51.cloudflare.com (199.27.134.51) 39.803 ms 27.516 ms 29.485 ms

Jaring, TM, PACNET, C&W are ASN
=========================================================

traceroute to www.utp.edu.my (203.135.191.100), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.321 ms 0.361 ms 0.412 ms
2 10.64.0.1 (10.64.0.1) 0.444 ms 0.509 ms 0.609 ms
3 10.15.0.17 (10.15.0.17) 0.524 ms 0.585 ms 0.639 ms
4 244-subnet236.unimas.my (49.50.236.244) 2.280 ms 2.280 ms 2.374 ms
5 1-subnet236.unimas.my (49.50.236.1) 2.375 ms 1-subnet87.unimas.my (161.142.87.1) 2.297 ms 2.353 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 22.389 ms 21.602 ms 21.796 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 45.283 ms 44.018 ms 44.604 ms
8 203.80.22.161 (203.80.22.161) 43.972 ms 48.542 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 49.400 ms
9 fa0-2-0-01001-utp-pe01-v4.23.80.203.in-addr.arpa (203.80.23.82) 43.744 ms pos0-3-0-1.mlk95 (61.6.17.45 Jaring) 50.913 ms fa0-2-0-01001-utp-pe01-v4.23.80.203.in-addr.arpa (203.80.23.82) 43.058 ms
10 f1-0-utp-ce-v4.myren.net.my (203.80.18.146) 31.505 ms 31.498 ms 31.472 ms
11 www.utp.edu.my (203.135.191.100) 32.778 ms te0-2-0-0.bkj95.jaring.my (61.6.51.17) 56.080 ms www.utp.edu.my (203.135.191.100) 43.420 ms

MYREN and Jaring
=========================================================

traceroute to www.qiup.edu.my (103.6.196.75), 30 hops max, 60 byte packets
1 10.64.113.1 (10.64.113.1) 0.344 ms 0.385 ms 0.445 ms
2 10.64.0.1 (10.64.0.1) 0.431 ms 0.484 ms 0.546 ms
3 10.15.0.17 (10.15.0.17) 0.445 ms 0.501 ms 0.571 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.256 ms 1.297 ms 1.321 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.500 ms 1.503 ms 1.491 ms
6 58.26.240.61 (58.26.240.61 TM) 2.122 ms 1.936 ms 2.067 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 10.241 ms * 9.615 ms
8 218.100.44.113 (218.100.44.113 Unknown) 39.101 ms 38.783 ms 36.711 ms
9 110.4.44.218 (110.4.44.218 mschosting) 35.614 ms 36.774 ms 34.748 ms
10 kritosaurus.mschosting.com (103.6.196.75) 24.248 ms 34.015 ms 21.654 ms

  1. Is this really at QIUP? ISPs TM, Jaring
    =========================================================
traceroute to www.allianzeunicollege.edu.my (110.4.41.15), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.342 ms 0.381 ms 0.445 ms
2 10.64.0.1 (10.64.0.1) 0.426 ms 0.483 ms 0.537 ms
3 10.15.0.17 (10.15.0.17) 0.663 ms 0.700 ms 0.842 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.158 ms 1.049 ms 1.193 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.393 ms 1.476 ms 1.277 ms
6 58.26.240.61 (58.26.240.61 TM) 2.039 ms 161.142.6.205 (161.142.6.205 Jaring) 7.577 ms 58.26.240.61 (58.26.240.61 TM) 1.890 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.242 ms * *
8 218.100.44.113 (218.100.44.113 Unknown) 37.262 ms 38.568 ms 36.616 ms
9 110.4.44.218 (110.4.44.218 mschosting) 36.075 ms 36.073 ms 35.389 ms
10 server.acms.edu.my (110.4.41.15 mschosting) 32.965 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 55.827 ms 55.193 ms

mschosting AKA ExaBytes cloud, carriers Jaring, TM
=========================================================

traceroute to www.newinti.edu.my (124.150.142.118), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.338 ms 0.358 ms 0.408 ms
2 10.64.0.1 (10.64.0.1) 0.472 ms 0.547 ms 0.601 ms
3 10.15.0.17 (10.15.0.17) 0.450 ms 0.511 ms 0.548 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.939 ms 0.950 ms 0.986 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.218 ms 1.174 ms 1.208 ms
6 58.26.240.61 (58.26.240.61 TM) 1.930 ms 1.791 ms 1.760 ms
7 * * gi0-1-1-0.kch95.jaring.my (61.6.47.33) 9.839 ms
8 webserver.myix.gov.my (218.100.44.108 Unknown) 31.999 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.094 ms webserver.myix.gov.my (218.100.44.108) 36.013 ms
9 * * *
10 124.150.142.118 (124.150.142.118) 50.640 ms 40.049 ms 35.485 ms

ISPs are Jaring, TM
=========================================================

traceroute to www.mmu.edu.my (203.106.61.79), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.315 ms 0.352 ms 0.403 ms
2 10.64.0.1 (10.64.0.1) 0.478 ms 0.535 ms 0.590 ms
3 10.15.0.17 (10.15.0.17) 0.444 ms 0.500 ms 0.555 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.953 ms 1.268 ms 1.350 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.523 ms 1.521 ms 1.517 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.194 ms 161.142.6.205 (161.142.6.205) 7.543 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.183 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 9.557 ms f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 23.888 ms 40.604 ms
8 203.80.22.161 (203.80.22.161 MYREN) 41.083 ms 27.735 ms 37.174 ms
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 38.334 ms 24.841 ms 26.536 ms
10 f0-2-0-mmu-pe01-v4.myren.net.my (203.80.23.22) 23.579 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 54.550 ms f0-2-0-mmu-pe01-v4.myren.net.my (203.80.23.22) 23.711 ms
11 58.27.101.129 (58.27.101.129 TM) 82.959 ms 203.106.66.66 (203.106.66.66 MYREN) 33.701 ms 33.713 ms
12 203.106.66.134 (203.106.66.134 MYREN) 37.572 ms 37.769 ms 37.927 ms
13 203.106.61.79 (203.106.61.79 MYREN) 42.038 ms 218.208.72.26 (218.208.72.26) 59.906 ms 203.106.61.79 (203.106.61.79) 42.222 ms
14 203.106.61.79 (203.106.61.79 MYREN) 60.810 ms 41.943 ms 41.879 ms

End host in MYREN, ISP is MYREN
=========================================================

traceroute to www.unikl.edu.my (113.23.141.10), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.318 ms 0.358 ms 0.409 ms
2 10.64.0.1 (10.64.0.1) 0.499 ms 0.568 ms 0.651 ms
3 10.15.0.17 (10.15.0.17) 0.511 ms 0.566 ms 0.628 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.239 ms 1.098 ms 1.097 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.440 ms 1.435 ms 1.416 ms
6 58.26.240.61 (58.26.240.61 TM) 67.481 ms 161.142.6.205 (161.142.6.205 Jaring) 7.780 ms 7.677 ms
7 * * *
8 218.100.44.140 (218.100.44.140 Unknown) 32.865 ms 33.478 ms 31.239 ms
9 113.23.163.177 (113.23.163.177 Unknown) 31.950 ms 33.984 ms 33.403 ms
10 113.23.163.78 (113.23.163.78 Unknown) 41.730 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 56.005 ms 113.23.163.78 (113.23.163.78 Unknown)) 40.419 ms
11 te0-2-0-0.bkj95.jaring.my (61.6.51.17) 56.544 ms 113.23.133.197 (113.23.133.197) 29.450 ms 29.413 ms
12 113.23.161.26 (113.23.161.26 Extreme Broadband) 42.886 ms 42.150 ms 41.923 ms
13 113.23.170.197 (113.23.170.197 Unknown) 46.317 ms 218.100.44.140 (218.100.44.140 Unknown) 53.949 ms 113.23.170.197 (113.23.170.197 Unknown) 44.906 ms
14 113.23.163.177 (113.23.163.177 Unknown) 54.029 ms 113.23.141.10 (113.23.141.10 Extreme Broadband) 46.630 ms 47.194 ms
15 113.23.141.10 (113.23.141.10) 32.603 ms 44.652 ms 42.744 ms

Carriers Jaring, Extreme Broadband
=========================================================

traceroute to www.utar.edu.my (58.27.19.137), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.328 ms 0.370 ms 0.421 ms
2 10.64.0.1 (10.64.0.1) 0.444 ms 0.517 ms 0.575 ms
3 10.15.0.17 (10.15.0.17) 0.468 ms 0.522 ms 0.576 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.921 ms 0.984 ms 0.983 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.274 ms 1.281 ms 1.293 ms
6 58.26.240.61 (58.26.240.61 MT) 2.008 ms 1.543 ms 1.616 ms
7 * * gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.275 ms
8 58.26.179.14 (58.26.179.14 TM) 45.686 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.883 ms 58.26.179.14 (58.26.179.14 TM) 47.014 ms
9 www.utar.edu.my (58.27.19.137 TM) 34.928 ms 37.707 ms 33.241 ms

Carriers Extreme Broadband, Jaring
=========================================================

traceroute to www.mahsa.edu.my (175.139.189.25), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.360 ms 0.400 ms 0.453 ms
2 10.64.0.1 (10.64.0.1) 0.478 ms 0.553 ms 0.612 ms
3 10.15.0.17 (10.15.0.17) 0.485 ms 0.560 ms 0.644 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.013 ms 1.012 ms 1.122 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.334 ms 1.311 ms 1-subnet87.unimas.my (161.142.87.1) 1.312 ms
6 58.26.240.61 (58.26.240.61 TM) 1.728 ms 1.841 ms 1.811 ms
7 * * *
8 175.144.91.130 (175.144.91.130 TM) 38.990 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205 TM) 49.382 ms 48.753 ms
9 175.139.189.25 (175.139.189.25 Unknown) 38.314 ms 38.150 ms 38.121 ms

Carriers TM and Jaring
=========================================================

traceroute to www.miu.edu.my (220.226.189.71), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.343 ms 0.383 ms 0.433 ms
2 10.64.0.1 (10.64.0.1) 0.455 ms 0.534 ms 0.592 ms
3 10.15.0.17 (10.15.0.17) 0.474 ms 0.533 ms 0.586 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.043 ms 1.043 ms 1.114 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.276 ms 1.273 ms 1-subnet87.unimas.my (161.142.87.1) 1.251 ms
6 58.26.240.61 (58.26.240.61 TM) 2.732 ms 2.812 ms 2.759 ms
7 * * *
8 xe-7-2-0.lon21.ip4.tinet.net (77.67.75.149 TINET, Inteliquent) 219.186 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 49.648 ms 49.046 ms #London?
9 xe-5-2-1.lax30.ip4.tinet.net (141.136.111.97) 298.085 ms 296.385 ms 298.049 ms #Los Angeles?
10 flag-telecom-ireland-network-gw.ip4.tinet.net (199.229.231.166) 281.749 ms 282.902 ms 284.943 ms
11 so-2-1-3.0.pjr01.wad001.flagtel.com (62.216.128.69) 342.361 ms so-2-1-2.0.pjr01.wad001.flagtel.com (62.216.128.165) 352.435 ms 349.707 ms
12 ge-6-0-0.0.ejr01.chn001.flagtel.com (62.216.135.225) 90.349 ms so-0-0-0.0.pjr01.hkg005.flagtel.com (85.95.25.194) 282.987 ms 284.226 ms $Hong Kong, Chennai
13 so-0-3-0.0.pjr01.mmb004.flagtel.com (85.95.25.238) 360.788 ms 357.898 ms 360.868 ms #Mumbai?
14 * * *
15 * * *
16 202.138.117.210 (202.138.117.210 Reliance) 340.828 ms 341.629 ms 343.332 ms
17 202.138.113.1 (202.138.113.1) 347.209 ms 345.638 ms 348.311 ms
18 202.138.112.241 (202.138.112.241) 344.961 ms 345.502 ms 202.138.112.66 (202.138.112.66) 118.536 ms
19 220.226.192.58 (220.226.192.58 Reliance) 362.833 ms 361.306 ms 359.464 ms
20 220.226.189.68 (220.226.189.68) 355.620 ms 356.774 ms 357.072 ms
21 * * *
22 220.226.189.71 (220.226.189.71) 362.978 ms 366.862 ms 361.713 ms

Strange route, 360ms appears to go to GB, India
=========================================================

traceroute to www.aiu.edu.my (110.4.45.135), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.348 ms 0.504 ms 0.577 ms
2 10.64.0.1 (10.64.0.1) 0.645 ms 0.721 ms 0.802 ms
3 10.15.0.17 (10.15.0.17) 2.119 ms 2.282 ms 2.353 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.932 ms 1.020 ms 1.091 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.172 ms 1.456 ms 1.536 ms
6 58.26.240.61 (58.26.240.61 TM) 2.134 ms 1.971 ms 161.142.6.205 (161.142.6.205) 11.365 ms
7 * * *
8 218.100.44.113 (218.100.44.113 Unknown) 39.386 ms 38.434 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 49.455 ms
9 110.4.44.218 (110.4.44.218 mschosting) 34.625 ms 41.435 ms 41.271 ms
10 poseidon.mschosting.com (110.4.45.135) 38.056 ms 37.283 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 56.132 ms

mschosting
=========================================================

traceroute to www.maxis.com.my (202.75.129.146), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.327 ms 0.421 ms 0.483 ms
2 10.64.0.1 (10.64.0.1) 0.542 ms 0.653 ms 0.763 ms
3 10.15.0.17 (10.15.0.17) 0.573 ms 0.688 ms 0.789 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.365 ms 1.469 ms 1.515 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.656 ms 1.744 ms 1.573 ms
6 58.26.240.61 (58.26.240.61 TM) 2.246 ms 1.973 ms 1.829 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.651 ms * 11.102 ms
8 maxis.myix.gov.my (218.100.44.80) 32.887 ms 32.963 ms 36.731 ms
9 202.151.241.153 (202.151.241.153) 39.810 ms 39.165 ms 39.216 ms
10 gi1-0-0.sgbp-pe90a.maxis.net.my (202.151.241.14) 35.511 ms 35.413 ms 34.504 ms
11 te-0-1-1-0.drc95.jaring.my (61.6.51.1) 54.945 ms 202.151.252.46 (202.151.252.46) 23.130 ms te-0-1-1-0.drc95.jaring.my (61.6.51.1) 54.292 ms
12 202.75.129.146 (202.75.129.146) 38.005 ms 36.571 ms 25.224 ms

ISPs TM & Jaring, maxis.gov.my
=========================================================

traceroute to www.celcom.com.my (203.82.70.227), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.328 ms 0.413 ms 0.463 ms
2 10.64.0.1 (10.64.0.1) 0.513 ms 0.661 ms 0.769 ms
3 10.15.0.17 (10.15.0.17) 0.535 ms 0.583 ms 0.676 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.992 ms 1.094 ms 1.033 ms
5 1-subnet87.unimas.my (161.142.87.1) 1.243 ms 1-subnet236.unimas.my (49.50.236.1) 1.625 ms 1-subnet87.unimas.my (161.142.87.1) 1.278 ms
6 58.26.240.61 (58.26.240.61 TM) 2.194 ms 1.669 ms 1.710 ms
7 * * *
8 ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.537 ms 1.9.244.46 (1.9.244.46) 24.510 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.591 ms
9 * * *
10 * * *
11 * * *
12 te0-0-0-0.bkj96.jaring.my (61.6.10.2) 55.032 ms * *
13 * * celcom.myix.gov.my (218.100.44.87) 55.572 ms
14 www.celcom.com.my (203.82.70.227) 39.520 ms 37.941 ms 42.882 ms

ISPs TM, Jaring, myix.gov.my
=========================================================

traceroute to shinjiru.com.my (111.90.143.33), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.354 ms 0.487 ms 0.655 ms
2 10.64.0.1 (10.64.0.1) 0.557 ms 0.733 ms 0.895 ms
3 10.15.0.17 (10.15.0.17) 0.804 ms 0.950 ms 1.017 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.083 ms 1.154 ms 1.232 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.298 ms 2.087 ms 1.568 ms
6 58.26.240.61 (58.26.240.61 TM) 2.162 ms 1.713 ms 1.836 ms
7 * * *
8 globaltransit-my.myix.gov.my (218.100.44.67) 51.644 ms 51.083 ms 51.218 ms
9 pos0-3-0-1.mlk95 (61.6.17.45 Jaring) 51.100 ms xe-0-2-0-0.edge-gw-1-kul-pip.my.globaltransit.net (61.11.210.176) 34.977 ms pos0-3-0-1.mlk95 (61.6.17.45 Jaring) 50.480 ms # Kuala Lumpur, Malaka?
10 119.110.8.42 (119.110.8.42) 37.432 ms 39.709 ms 37.446 ms
11 111.90.143.33 (111.90.143.33) 23.367 ms 20.926 ms 24.586 ms

ISPs TM, globaltransit-my.myix.gov.my
=========================================================

traceroute to datakl.com (210.48.148.222), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.328 ms 0.428 ms 0.520 ms
2 10.64.0.1 (10.64.0.1) 0.586 ms 0.705 ms 0.890 ms
3 10.15.0.17 (10.15.0.17) 0.622 ms 0.737 ms 0.804 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.196 ms 1.053 ms 1.110 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.632 ms 1.703 ms 1-subnet87.unimas.my (161.142.87.1) 1.217 ms
6 58.26.240.61 (58.26.240.61 TM) 2.423 ms 2.592 ms 2.676 ms
7 * gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.422 ms *
8 ge0-2-0-4-mea95.jaring.my (61.6.97.205) 50.124 ms 1.9.33.206 (1.9.33.206) 47.876 ms 47.721 ms
9 202.75.52.1 (202.75.52.1) 78.004 ms 77.557 ms 77.838 ms
10 datakl.com 210.48.148.222 (210.48.148.222) 42.587 ms 47.725 ms 43.431 ms
ISPs Jaring
=========================================================

traceroute to emerge.com.my (210.48.155.230), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 1.542 ms 1.562 ms 1.603 ms
2 10.64.0.1 (10.64.0.1) 0.461 ms 0.550 ms 0.596 ms
3 10.15.0.17 (10.15.0.17) 1.846 ms 1.927 ms 2.079 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.165 ms 1.262 ms 1.312 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.982 ms 1.929 ms 1-subnet87.unimas.my (161.142.87.1) 1.338 ms
6 58.26.240.61 (58.26.240.61 TM) 2.081 ms 1.601 ms 1.665 ms
7 * * gi0-1-1-0.kch95.jaring.my (61.6.47.33) 12.244 ms
8 1.9.33.206 (1.9.33.206) 49.566 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 50.243 ms 1.9.33.206 (1.9.33.206) 49.260 ms
9 202.75.52.1 (202.75.52.1) 51.890 ms 61.409 ms 60.864 ms
10 * * *
11 * te-0-1-1-0.drc95.jaring.my (61.6.51.1) 55.283 ms *
12 te0-1-0-0.bkj96.jaring.my (61.6.51.13) 53.979 ms 53.703 ms *
13 * * *
14 * * *
15 1.9.33.206 (1.9.33.206) 56.394 ms * *
16 202.75.52.1 (202.75.52.1) 195.406 ms * 195.312 ms
17 210.48.155.230 (210.48.155.230) 57.539 ms * *

=========================================================

traceroute to www.btu.upm.edu.my (119.40.116.240), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.298 ms 0.444 ms 0.336 ms
2 10.64.0.1 (10.64.0.1) 0.409 ms 0.467 ms 0.555 ms
3 10.15.0.17 (10.15.0.17) 0.477 ms 0.543 ms 0.589 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.878 ms 0.942 ms 0.954 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.025 ms 1.186 ms 1.016 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.311 ms 21.031 ms 161.142.6.205 (161.142.6.205) 7.535 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 42.255 ms 42.669 ms 25.771 ms
8 203.80.22.161 (203.80.22.161 MYREN) 35.965 ms 24.652 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 50.512 ms
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 25.696 ms 27.248 ms 42.476 ms
10 f0-2-0-upm-pe01-v4.myren.net.my (203.80.23.6) 34.912 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 55.850 ms f0-2-0-upm-pe01-v4.myren.net.my (203.80.23.6) 35.066 ms
11 gi0-3-upm-ce-v4.myren.net.my (203.80.18.178) 22.185 ms 21.816 ms 21.797 ms
12 119.40.118.253 (119.40.118.253 UPM) 62.767 ms 44.327 ms 44.290 ms
13 * * *
14 * * *
15 161.142.19.181 (161.142.19.181 Jaring) 49.239 ms 27.440 ms 27.409 ms
16 fe4-1-0.mup15.jaring.my (61.6.189.9) 95.666 ms p3491.sgw.equinix.com (202.79.197.43) 61.408 ms fe4-1-0.mup15.jaring.my (61.6.189.9) 87.117 ms
17 pos0-3-2-3.bkj95.jaring.my (161.142.23.169) 83.038 ms 86.172 ms 86.136 ms
18 te0-0-0-0.bkj96.jaring.my (61.6.10.2) 81.498 ms 96.150 ms 96.142 ms
19 te-0-2-0-0.drc95.jaring.my (61.6.51.14) 77.653 ms 124.158.224.91 (124.158.224.91) 87.166 ms 87.324 ms
20 ge0-1-0-2-ktk95.jaring.my (61.6.97.54) 82.677 ms 78.643 ms 84.617 ms
21 ae-1.cr-02-glsfb.ni.time.net.my (223.28.2.121 Unknown) 65.284 ms ge0-1-mri.jaring.my (161.142.0.106) 79.986 ms 79.980 ms
22 s5-0.btl.jaring.my (61.6.5.122) 69.069 ms 68.890 ms 68.880 ms
23 161.142.19.105 (161.142.19.105 Jaring) 72.268 ms 70.086 ms 70.057 ms
24 161.142.19.106 (161.142.19.106 Jaring) 71.358 ms 70.792 ms 71.761 ms
25 xe-0-0-0-0.er-01-akhmw.ni.time.net.my (223.28.2.54) 72.994 ms * 71.976 ms
26 www.btu.upm.edu.my (119.40.116.240) 80.764 ms 84.707 ms 70.911 ms

ISPs MYREN, Jaring

Brunei targets

traceroute to www.ubd.edu.bn (202.160.1.54), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.398 ms 0.433 ms 0.490 ms
2 10.64.0.1 (10.64.0.1) 0.510 ms 0.543 ms 0.622 ms
3 10.15.0.17 (10.15.0.17) 1.608 ms 1.683 ms 1.774 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.145 ms 1.024 ms 1.173 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.702 ms 1-subnet87.unimas.my (161.142.87.1) 1.339 ms 1-subnet236.unimas.my (49.50.236.1) 1.285 ms
6 58.26.240.61 (58.26.240.61 TM) 2.213 ms 1.977 ms 1.856 ms
7 * * *
8 203.208.171.193 (203.208.171.193) 53.809 ms 203.208.166.9 (203.208.166.9) 53.978 ms 203.208.186.77 (203.208.186.77 SINGTEL) 49.835 ms
9 ge-2-0-0-0.sngtp-dr2.ix.singtel.com (203.208.149.190) 62.704 ms ge0-3-0-0.mea97.jaring.my (61.6.18.6) 49.750 ms 49.824 ms
10 203.208.175.86 (203.208.175.86) 100.831 ms 98.441 ms 97.271 ms
11 te-0-1-1-0-crth.brunet.bn (61.6.255.106) 100.441 ms 95.922 ms 96.501 ms
12 te-9-3-nsth.brunet.bn (61.6.255.126) 92.054 ms 95.661 ms 91.860 ms
13 11-222.static.espeed.com.bn (202.93.222.11) 95.979 ms 99.383 ms 97.935 ms
14 18-222.static.espeed.com.bn (202.93.222.18) 84.381 ms 11-222.static.espeed.com.bn (202.93.222.11) 68.883 ms 18-222.static.espeed.com.bn (202.93.222.18) 82.112 ms
15 22-222.static.espeed.com.bn (202.93.222.22) 84.631 ms 88.488 ms 87.384 ms
16 202.160.1.54 (202.160.1.54) 87.277 ms 97.751 ms 22-222.static.espeed.com.bn (202.93.222.22) 69.819 ms

ISPs TM, SINGTEL, BRUNET, ESPEED

=========================================================

Indonesion targets

traceroute to www.usu.ac.id (202.0.107.9), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.366 ms 0.407 ms 0.501 ms
2 10.64.0.1 (10.64.0.1) 0.434 ms 0.541 ms 0.602 ms
3 10.15.0.17 (10.15.0.17) 0.489 ms 0.550 ms 0.615 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.884 ms 1.108 ms 1.047 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.466 ms 1.410 ms 1.479 ms
6 161.142.6.205 (161.142.6.205 Jaring) 7.871 ms 7.822 ms 58.26.240.61 (58.26.240.61 TM) 1.628 ms
7 * * *
8 58.27.107.194 (58.27.107.194 TM) 56.727 ms 57.287 ms 58.348 ms
9 JNode1-acl.so3-0-1.pkm.JGW01.Medan.Indosat.com (124.195.57.217) 72.107 ms 72.511 ms ge0-3-0-0.mea97.jaring.my (61.6.18.6) 49.395 ms
10 124.195.60.26 (124.195.60.26 INDOSAT) 73.182 ms 203.208.186.129 (203.208.186.129 SINGTEL) 47.574 ms 124.195.60.26 (124.195.60.26) 74.053 ms
11 202.0.107.9 (202.0.107.9) 79.102 ms 76.342 ms 62.742 ms

ISPs Jaring, TM, INDOSAT, SINGTEL
=========================================================

traceroute to www.uinjkt.ac.id (103.12.240.22), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 1.263 ms 1.404 ms 1.540 ms
2 10.64.0.1 (10.64.0.1) 0.472 ms 0.720 ms 0.861 ms
3 10.15.0.17 (10.15.0.17) 0.612 ms 0.771 ms 0.911 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.237 ms 1.048 ms 1.380 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.841 ms 1-subnet87.unimas.my (161.142.87.1) 2.006 ms 1.928 ms
6 58.26.240.61 (58.26.240.61 TM) 2.153 ms 1.640 ms 1.782 ms
7 * * *
8 * * *
9 ge0-3-0-0.mea97.jaring.my (61.6.18.6) 51.711 ms IP-112-217.MCS.napinfo.net (119.110.112.217) 272.194 ms 273.242 ms
10 IP-112-250.MCS.napinfo.net (119.110.112.250) 92.008 ms 92.123 ms 96.055 ms
11 IP-121-98.MCS.napinfo.net (119.110.121.98) 97.171 ms 97.073 ms 97.191 ms
12 ptp-1-core3-brd82.orion.net.id (203.84.155.1) 97.267 ms 94.815 ms 97.625 ms
13 IP-112-238.MCS.napinfo.net (119.110.112.238) 95.386 ms ultrium.net.ge9.2.br02.sin02.pccwbtn.net (63.218.213.158) 98.482 ms 94.178 ms
14 2.247.31.114.platinum.net.id (114.31.247.2) 84.644 ms 84.810 ms 84.877 ms
15 14.247.31.114.platinum.net.id (114.31.247.14) 101.533 ms 97.800 ms 97.621 ms
16 103.12.240.254 (103.12.240.254 Unknown) 89.317 ms 85.590 ms 84.686 ms
17 2.247.31.114.platinum.net.id (114.31.247.2) 95.192 ms 103.12.240.22 (103.12.240.22) 96.466 ms 106.026 ms

ISPs TM, Jaring, NAPINFO, PCCWBTN, PLATINUM
=========================================================

traceroute to www.itb.ac.id (167.205.1.34), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.346 ms 0.476 ms 0.627 ms
2 10.64.0.1 (10.64.0.1) 0.548 ms 0.667 ms 0.801 ms
3 10.15.0.17 (10.15.0.17) 0.726 ms 0.843 ms 0.898 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.058 ms 0.991 ms 1.122 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.706 ms 1.618 ms 1.755 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.483 ms 161.142.6.205 (161.142.6.205 Jaring) 8.481 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.327 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 10.209 ms f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 37.817 ms 37.517 ms
8 203.80.22.161 (203.80.22.161 MYREN) 39.278 ms 42.506 ms 28.279 ms
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 36.321 ms 39.703 ms 23.684 ms
10 gi0-2-0-cbj-ibr-v4.myren.net.my (203.80.23.58) 22.333 ms 203.208.186.129 (203.208.186.129 SINGTEL) 47.554 ms gi0-2-0-cbj-ibr-v4.myren.net.my (203.80.23.58) 22.745 ms
11 so-7-0-0-0.sngc3-ar4.ix.singtel.com (203.208.152.33) 47.770 ms * *
12 hk-xe-03-v4.bb.tein3.net (202.179.241.101) 110.088 ms 110.557 ms 110.418 ms
13 202.152.0.56 (202.152.0.56 LINTASARTA) 62.202 ms * *
14 vlan50-v4-itb-pop.inherent-dikti.net (167.205.132.2) 83.558 ms 83.560 ms 83.885 ms
15 AI3-NOC-PAU-Cat6-Vlan.ITB.ac.id (167.205.23.3) 81.768 ms 81.680 ms 81.428 ms
16 www.itb.ac.id (167.205.1.34) 82.460 ms 93.636 ms 83.642 ms

ISPs MYREN, Jaring, SINGTEL, TEIN3, LINTASARTA, INHERENT
=========================================================

traceroute to www.ugm.ac.id (175.111.88.11), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.333 ms 0.451 ms 0.582 ms
2 10.64.0.1 (10.64.0.1) 0.504 ms 0.635 ms 0.695 ms
3 10.15.0.17 (10.15.0.17) 1.564 ms 1.736 ms 1.870 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.257 ms 1.142 ms 1.296 ms
5 1-subnet87.unimas.my (161.142.87.1) 1.349 ms 1-subnet236.unimas.my (49.50.236.1) 1.763 ms 1-subnet87.unimas.my (161.142.87.1) 1.400 ms
6 58.26.240.61 (58.26.240.61 TM) 2.536 ms 1.908 ms 2.011 ms
7 * * *
8 58.27.14.58 (58.27.14.58 TM) 55.432 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 49.338 ms 58.27.14.58 (58.27.14.58 TM) 55.525 ms
9 ge0-3-0-0.mea97.jaring.my (61.6.18.6) 49.010 ms 142.subnet118-98-61.astinet.telkom.net.id (118.98.61.142 TELKOMNET) 51.387 ms 50.295 ms
10 169.subnet118-98-12.astinet.telkom.net.id (118.98.12.169) 64.364 ms 64.449 ms 64.511 ms
11 38.subnet118-98-56.astinet.telkom.net.id (118.98.56.38) 83.749 ms 83.001 ms 87.069 ms
12 170.subnet118-98-53.astinet.telkom.net.id (118.98.53.170) 77.418 ms 76.726 ms 76.192 ms
13 166.subnet118-98-53.astinet.telkom.net.id (118.98.53.166) 83.651 ms 80.784 ms 80.269 ms
14 61.5.118.230 (61.5.118.230 TELCOMNET)) 78.815 ms 79.016 ms 79.127 ms
15 118.97.5.122 (118.97.5.122 TELCOMNET) 87.269 ms 83.206 ms 83.512 ms
16 ns1.ugm.ac.id (202.43.92.2) 70.261 ms 66.434 ms 66.484 ms
17 host-175-111-88-11.ugm.ac.id (175.111.88.11) 68.962 ms 67.502 ms 71.311 ms

ISPs TM, Jaring, TELCOMNET
=========================================================

traceroute to www.unair.ac.id (210.57.208.14), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.910 ms 0.983 ms 1.769 ms
2 10.64.0.1 (10.64.0.1) 0.409 ms 0.532 ms 0.596 ms
3 10.15.0.17 (10.15.0.17) 1.796 ms 1.852 ms 1.903 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.977 ms 1.047 ms 1.104 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.460 ms 1-subnet87.unimas.my (161.142.87.1) 1.600 ms 1-subnet236.unimas.my (49.50.236.1) 1.534 ms
6 58.26.240.61 (58.26.240.61 TM) 1.956 ms 2.171 ms 161.142.6.205 (161.142.6.205 Jaring) 7.276 ms
7 * * *
8 58.27.14.150 (58.27.14.150 TM) 29.862 ms 58.27.14.58 (58.27.14.58) 44.017 ms 58.27.14.150 (58.27.14.150 TM) 29.331 ms
9 142.subnet118-98-61.astinet.telkom.net.id (118.98.61.142) 39.775 ms 38.220 ms 40.234 ms
10 169.subnet118-98-12.astinet.telkom.net.id (118.98.12.169) 55.626 ms 203.208.186.129 (203.208.186.129 SINGTEL) 47.688 ms 169.subnet118-98-12.astinet.telkom.net.id (118.98.12.169) 56.066 ms
11 38.subnet118-98-56.astinet.telkom.net.id (118.98.56.38) 75.562 ms 75.024 ms 74.912 ms
12 61.5.116.174 (61.5.116.174) 72.927 ms 73.182 ms 142.subnet118-98-61.astinet.telkom.net.id (118.98.61.142) 82.357 ms
13 169.subnet118-98-12.astinet.telkom.net.id (118.98.12.169) 110.321 ms ppp-spl-a.telkom.net.id (61.5.48.169) 57.356 ms 58.157 ms
14 118.97.5.38 (118.97.5.38 TELCOMNET) 112.383 ms 107.261 ms 100.036 ms
15 210.57.223.50 (210.57.223.50 UNAIR) 71.157 ms 80.328 ms 80.200 ms
16 ppp-spl-a.telkom.net.id (61.5.48.169) 109.912 ms unair.ac.id (210.57.208.14) 68.239 ms 66.877 ms

ISPs TM, Jaring, TELCOMNET, SINGTEL, UNAIR
=========================================================

traceroute to www.untan.ac.id (203.24.50.2), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.354 ms 0.464 ms 0.629 ms
2 10.64.0.1 (10.64.0.1) 0.546 ms 0.687 ms 0.745 ms
3 10.15.0.17 (10.15.0.17) 0.802 ms 0.873 ms 0.941 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.131 ms 1.051 ms 1.202 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.399 ms 1.473 ms 1.298 ms
6 58.26.240.61 (58.26.240.61 TM) 29.551 ms 26.345 ms 161.142.6.205 (161.142.6.205 Jaring) 7.893 ms
7 * * *
8 58.27.14.150 (58.27.14.150 TM) 39.773 ms 39.787 ms 58.27.14.58 (58.27.14.58) 55.079 ms
9 142.subnet118-98-61.astinet.telkom.net.id (118.98.61.142) 50.909 ms 50.249 ms 53.922 ms
10 p7713.sgw.equinix.com (202.79.197.77) 81.701 ms 61.5.51.62 (61.5.51.62) 52.236 ms p7713.sgw.equinix.com (202.79.197.77) 81.606 ms
11 10.subnet118-98-10.astinet.telkom.net.id (118.98.10.10) 51.864 ms 199.292 ms 180.919 ms
12 118.97.6.162 (118.97.6.162 TELCOMNET) 46.623 ms 46.430 ms 47.522 ms
13 203.24.50.2 (203.24.50.2) 63.172 ms 49.979 ms 48.613 ms

ISPs TM, TELCOMNET, EQUINIX
=========================================================

Philippines targets

traceroute to www.swu.edu.ph (121.96.58.6), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.325 ms 0.362 ms 0.414 ms
2 10.64.0.1 (10.64.0.1) 0.489 ms 0.552 ms 0.604 ms
3 10.15.0.17 (10.15.0.17) 0.907 ms 0.971 ms 1.047 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.032 ms 1.102 ms 1.007 ms
5 1-subnet87.unimas.my (161.142.87.1) 1.217 ms 1.265 ms 1-subnet236.unimas.my (49.50.236.1) 1.657 ms
6 58.26.240.61 (58.26.240.61 TM) 2.073 ms 2.020 ms 1.991 ms #Still in Kuching
7 * * *
8 121.189.3.29 (121.189.3.29) 101.287 ms 99.768 ms 102.627 ms
9 112.174.83.49 (112.174.83.49) 104.248 ms ge0-3-0-0.mea97.jaring.my (61.6.18.6) 48.573 ms 112.174.83.49 (112.174.83.49) 104.558 ms #Possibly in Bukit Jalil, Kuala Lumpur
10 203.208.186.129 (203.208.186.129 SINGTEL) 47.783 ms 112.174.83.10 (112.174.83.10) 103.810 ms 102.164 ms
11 112.174.87.54 (112.174.87.54) 152.722 ms ge-3-0-0-0.sngc3-dr2.ix.singtel.com (203.208.151.162) 87.889 ms 112.174.87.54 (112.174.87.54) 150.983 ms #Singapore
12 203.208.191.178 (203.208.191.178) 91.875 ms 121.189.2.70 (121.189.2.70) 136.144 ms 136.060 ms
13 Te1-1.ccore1.rsv.bayan.net.ph (202.78.96.162) 136.744 ms 136.045 ms 136.050 ms
14 * * *
15 * * *
16 * * *
17 * * *
18 * * *
19 * * *
20 * * *
21 * * *
22 * * *
23 * * *
24 * * *
25 * * *
26 * * *
27 * * *
28 * * *
29 * * *
30 * * *

Jaring and SingTel are ISPs
========================================================

traceroute to www.auf.edu.ph (210.4.97.195), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.353 ms 0.388 ms 0.439 ms
2 10.64.0.1 (10.64.0.1) 0.516 ms 0.586 ms 0.647 ms
3 10.15.0.17 (10.15.0.17) 0.499 ms 0.564 ms 0.626 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.148 ms 1.148 ms 1.145 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.777 ms 1.761 ms 1.766 ms
6 58.26.240.61 (58.26.240.61) 2.120 ms 2.116 ms 161.142.6.205 (161.142.6.205 Jaring) 8.359 ms #Still in Kuching
7 * gi0-1-1-0.kch95.jaring.my (61.6.47.33) 11.073 ms * # Kuching
8 63-218-211-45.static.pccwglobal.net (63.218.211.45) 70.519 ms 68.060 ms 71.465 ms
9 comclark-vlan50-gi1-9.br02.hkg04.pccwbtn.net (63.218.1.70) 72.345 ms 73.105 ms 75.930 ms
10 202.69.190.65 (202.69.190.65) 98.117 ms 98.263 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 54.057 ms
11 202.69.190.42 (202.69.190.42) 92.155 ms te0-2-0-0.bkj95.jaring.my (61.6.51.17) 54.734 ms 202.69.190.42 (202.69.190.42) 92.694 ms # Bukit Jalil, Kuala Lumpur 
12 210.4.97.78 (210.4.97.78) 93.927 ms 95.682 ms 93.873 ms
13 210.4.97.195 (210.4.97.195) 99.340 ms 82.569 ms 93.810 ms

PCCW Global, Jaring are ISPs.
=========================================================

Singapore targets

traceroute to www.nus.edu.sg (137.132.21.27), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.331 ms 0.409 ms 0.457 ms
2 10.64.0.1 (10.64.0.1) 0.499 ms 0.545 ms 0.583 ms
3 10.15.0.17 (10.15.0.17) 0.617 ms 0.648 ms 0.689 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.968 ms 1.089 ms 1.030 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.851 ms 1-subnet87.unimas.my (161.142.87.1) 1.158 ms 1-subnet236.unimas.my (49.50.236.1) 1.735 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.395 ms 21.270 ms 161.142.6.205 (161.142.6.205 Jaring) 7.668 ms
7 f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 37.294 ms 40.294 ms 37.026 ms
8 203.80.22.161 (203.80.22.161 MYREN) 23.675 ms 23.147 ms 25.290 ms
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 24.966 ms 41.201 ms pos0-3-0-1.mlk95 (61.6.17.45 61.6.17.45) 52.090 ms
10 pos0-2-0-0.drc96.jaring.my (161.142.25.85) 54.045 ms gi0-2-0-cbj-ibr-v4.myren.net.my (203.80.23.58) 22.761 ms 22.826 ms
11 * * POS3-0-2.gw3.kul1.asianetcom.net (203.192.154.153) 53.009 ms
12 sg-pr-v4.bb.tein3.net (202.179.249.58) 42.361 ms 42.173 ms 42.553 ms
13 203.30.38.13 (203.30.38.13 SINGAREN) 31.258 ms 31.482 ms 31.149 ms
14 202.51.240.25 (202.51.240.25 NUS) 44.673 ms 43.967 ms 44.022 ms
15 nus-gw1.gigapop.nus.edu.sg (202.51.241.14) 40.947 ms NUS-0020.GW2.SIN1.asianetcom.net (202.147.33.178) 88.007 ms nus-gw1.gigapop.nus.edu.sg (202.51.241.14) 41.057 ms
16 * * 202.51.240.25 (202.51.240.25 NUS) 90.931 ms
17 * nus-gw1.gigapop.nus.edu.sg (202.51.241.14) 91.537 ms *
18 * * *
19 * * *
20 * * *
21 * * *
22 ddu.nus.edu.sg (137.132.21.27) 44.549 ms 28.719 ms 31.334 ms

ISPs MYREN, Jaring, SINGAREN
=========================================================

traceroute to www.singaporetech.edu.sg (119.31.233.174), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.544 ms 0.588 ms 0.685 ms
2 10.64.0.1 (10.64.0.1) 0.634 ms 0.700 ms 0.737 ms
3 10.15.0.17 (10.15.0.17) 0.804 ms 0.862 ms 0.916 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.185 ms 1.276 ms 1.214 ms
5 1-subnet87.unimas.my (161.142.87.1) 1.448 ms 1-subnet236.unimas.my (49.50.236.1) 1.646 ms 1.776 ms
6 161.142.6.205 (161.142.6.205 Jaring) 8.097 ms 58.26.240.61 (58.26.240.61 TM) 1.496 ms 1.490 ms
7 * * *
8 58.27.105.138 (58.27.105.138 TM) 40.806 ms ge0-2-0-4-mea95.jaring.my (61.6.97.205) 48.932 ms 58.27.105.138 (58.27.105.138 TM) 30.277 ms
9 ge0-3-0-0.mea97.jaring.my (61.6.18.6) 48.821 ms vlan907-an-cat6k-ts2-r1.starhub.net.sg (203.118.3.217) 30.067 ms 28.109 ms
10 203.118.7.35 (203.118.7.35 STARHUNINTERNET) 44.573 ms 44.550 ms 42.155 ms
11 203.116.10.126 (203.116.10.126 STARHUBINTERNET) 28.675 ms 28.757 ms 26.541 ms
12 ge-2-1-0.a088.m1net.sg (203.211.158.97 QUALA-SG) 28.835 ms 27.611 ms 28.810 ms
13 114.203-211-158.unknown.qala.com.sg (203.211.158.114) 43.707 ms 45.107 ms 43.217 ms
14 * * *
15 * r12-04-sh8-v144.cdp8.sgsvr.com (119.31.232.34) 42.140 ms *
16 vps.sit.edu.sg (119.31.233.174) 39.961 ms 41.107 ms 26.665 ms

ISPs Jaring, TM, STARHUNINTERNET, QALA
=========================================================

Thailand targets

Traceroute to www.ku.ac.th (158.108.216.5), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.323 ms 0.361 ms 0.413 ms
2 10.64.0.1 (10.64.0.1) 0.437 ms 0.496 ms 0.590 ms
3 10.15.0.17 (10.15.0.17) 0.517 ms 0.610 ms 0.638 ms
4 244-subnet236.unimas.my (49.50.236.244) 1.038 ms 1.337 ms 1.169 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.253 ms 1.407 ms 1.265 ms
6 f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 20.977 ms 161.142.6.205 (161.142.6.205 Jaring) 7.628 ms f0-2-2-unims-pe01-v4.myren.net.my (203.80.18.181) 21.016 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 8.961 ms f0-0-2-2-um-p-v4.myren.net.my (203.80.23.93) 38.329 ms 25.055 ms
8 203.80.22.161 (203.80.22.161 MYREN) 37.385 ms 41.139 ms 26.306 ms
9 gi0-0-1-0-cbj-p-v4.myren.net.my (203.80.22.129) 25.647 ms 25.468 ms 23.268 ms
10 gi0-2-0-cbj-ibr-v4.myren.net.my (203.80.23.58) 23.187 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 55.217 ms 54.510 ms
11 * * *
12 * * *
13 * * *
14 202.28.210.190 (202.28.210.190 Unknown) 57.730 ms te0-0-2-0.wr2.sin0.asianetcom.net (61.14.157.113) 61.205 ms 202.28.210.190 (202.28.210.190 Unknown) 59.633 ms
15 202.28.213.98 (202.28.213.98 Unknown) 69.578 ms 69.846 ms gi0-0-0.gw2.sin3.asianetcom.net (61.14.157.170 PACNET) 60.870 ms
16 c6509-backbone1.ku.ac.th (158.108.250.237 NONTRINET) 80.340 ms 78.126 ms 79.146 ms
17 158.108.250.198 (158.108.250.198 NONTRINET) 74.737 ms 77.103 ms 61.19.9.157 (61.19.9.157) 82.512 ms
18 www.ku.ac.th (158.108.216.5) 77.905 ms 64.589 ms 61.19.9.17 (61.19.9.17) 82.157 ms

ISPs Jaring, MYREN, ASIANET, NONTRINET
=========================================================

traceroute to www.mju.ac.th (110.164.58.213), 30 hops max, 60 byte packets

1 10.64.113.1 (10.64.113.1) 0.353 ms 0.394 ms 0.447 ms
2 10.64.0.1 (10.64.0.1) 0.469 ms 0.533 ms 0.585 ms
3 10.15.0.17 (10.15.0.17) 0.936 ms 1.007 ms 1.099 ms
4 244-subnet236.unimas.my (49.50.236.244) 0.980 ms 1.085 ms 1.064 ms
5 1-subnet236.unimas.my (49.50.236.1) 1.220 ms 1.311 ms 1.211 ms
6 58.26.240.61 (58.26.240.61 TM) 2.085 ms 1.600 ms 2.586 ms
7 gi0-1-1-0.kch95.jaring.my (61.6.47.33) 9.700 ms * *
8 202.47.252.237 (202.47.252.237 THAI-GATEWAY) 49.078 ms 47.717 ms 48.992 ms
9 61.19.9.129 (61.19.9.129 THAI-GATEWAY) 68.197 ms 69.661 ms pos0-3-0-1.mlk95 (61.6.17.45 Jaring) 50.488 ms
10 61.19.9.37 (61.19.9.37 THAI-GATEWAY) 65.955 ms pos0-2-0-0.drc96.jaring.my (161.142.25.85) 55.305 ms 61.19.9.37 (61.19.9.37 THAI-GATEWAY) 65.437 ms
11 61.19.9.114 (61.19.9.114 THAI-GATEWAY) 51.654 ms 52.466 ms 52.704 ms
12 61.19.15.242 (61.19.15.242 THAI-GATEWAY) 66.460 ms 66.271 ms 64.095 ms
13 po10-0-0.gw2.sin1.asianetcom.net (202.147.32.92) 62.017 ms mx-ll-110.164.0-122.static.3bb.co.th (110.164.0.122 TTGN-INTER) 54.526 ms 52.856 ms
14 mx-ll-110.164.1-77.static.3bb.co.th (110.164.1.77 TTGN-INTER) 73.911 ms 72.501 ms 72.237 ms
15 mx-ll-110.164.1-129.static.3bb.co.th (110.164.1.129 TTGN-INTER) 73.517 ms 72.971 ms gi0-0-0.gw2.sin3.asianetcom.net (61.14.157.170) 61.173 ms
16 mx-ll-110.164.1-111.static.3bb.co.th (110.164.1.111 TTGN-INTER) 67.394 ms p4651.sgw.equinix.com (202.79.197.88) 63.446 ms mx-ll-110.164.1-111.static.3bb.co.th (110.164.1.111 TTGN-INTER) 67.229 ms
17 mx-ll-110.164.1-120.static.3bb.co.th (110.164.1.120 TTGN-INTER) 67.299 ms 70.056 ms 69.136 ms
18 * * 61.19.9.29 (61.19.9.29 THAI-GATEWAY) 81.864 ms
19 * 61.19.9.34 (61.19.9.34 THAI-GATEWAY) 81.782 ms *
20 * * *
21 mx-ll-110-164-58-210.static.3bb.co.th (110.164.58.210 TTGN-INTER) 84.957 ms mx-ll-110.164.0-122.static.3bb.co.th (110.164.0.122 TTGN-INTER) 115.274 ms mx-ll-110-164-58-210.static.3bb.co.th (110.164.58.210 TTGN-INTER) 85.453 ms
22 * * *
23 * * *
24 * mx-ll-110.164.1-111.static.3bb.co.th (110.164.1.111 TTGN-INTER) 115.362 ms *
25 mx-ll-110.164.1-120.static.3bb.co.th (110.164.1.120 TTGN-INTER) 115.311 ms * *
26 * * *
27 * * *
28 * * *
29 * * *
30 * * *

ISPs TM, Jaring, THAI-GATEWAY, TTGN-INTER, EQUINIX, PACNET
=========================================================

  • No labels