Install Netlogger from Source
I downloaded Netlogger version 4.01
$ wget [http://pypi.python.org/packages/source/n/netlogger/netlogger-4.1.0.tar.gz#md5=6fc16362d2d677e58746bf00f320bea0] $ gunzip netlogger-4.1.0.tar.gz $ tar \-xvf netlogger-4.1.0.tar $ cd netlogger-4.1.0
$ sudo python setup.py build running build running build_py creating build creating build/lib.linux-i686-2.4 creating build/lib.linux-i686-2.4/netlogger copying netlogger/\__init_\_.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/bpize.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/configobj.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/logutil.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/nlapi.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/nlganglia.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/nllog.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/pipeline.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/talktome.py \-> build/lib.linux-i686-2.4/netlogger copying netlogger/util.py \-> build/lib.linux-i686-2.4/netlogger creating build/lib.linux-i686-2.4/netlogger/parsers copying netlogger/parsers/\__init_\_.py \-> build/lib.linux-i686-2.4/netlogger/parsers copying netlogger/parsers/base.py \-> build/lib.linux-i686-2.4/netlogger/parsers copying netlogger/parsers/config.py \-> build/lib.linux-i686-2.4/netlogger/parsers copying netlogger/parsers/nlparser.py \-> build/lib.linux-i686-2.4/netlogger/parsers copying netlogger/parsers/nlreadline.py \-> build/lib.linux-i686-2.4/netlogger/parsers creating build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/\__init_\_.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/bestman.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/bp.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/condorxml.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/csa_acct.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/dynamic.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/generic.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/gk.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/gridftp.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/gridftp_auth.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/jobstate.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/kickstart.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/ks.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/pbs.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/sge.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/sge_rpt.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules copying netlogger/parsers/modules/wsgram.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules creating build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/\__init_\_.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/bottleneck.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/filemon.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/histogram.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/lifeline.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/loader.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/loaderConfig.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/nlloader.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/schema.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/startend.py \-> build/lib.linux-i686-2.4/netlogger/analysis copying netlogger/analysis/wflowgen.py \-> build/lib.linux-i686-2.4/netlogger/analysis creating build/lib.linux-i686-2.4/netlogger/analysis/query copying netlogger/analysis/query/\__init_\_.py \-> build/lib.linux-i686-2.4/netlogger/analysis/query copying netlogger/analysis/query/base.py \-> build/lib.linux-i686-2.4/netlogger/analysis/query copying netlogger/analysis/query/describe.py \-> build/lib.linux-i686-2.4/netlogger/analysis/query copying netlogger/analysis/query/grep.py \-> build/lib.linux-i686-2.4/netlogger/analysis/query copying netlogger/analysis/schema.conf \-> build/lib.linux-i686-2.4/netlogger/analysis running build_ext building 'netlogger/parsers/modules/_ks' extension creating build/temp.linux-i686-2.4 creating build/temp.linux-i686-2.4/netlogger creating build/temp.linux-i686-2.4/netlogger/parsers creating build/temp.linux-i686-2.4/netlogger/parsers/modules gcc \-pthread \-fno-strict-aliasing \-DNDEBUG \-O2 \-g \-pipe \-Wall \-Wp,-D_FORTIFY_SOURCE=2 \-fexceptions \-fstack-protector \--param=ssp-buffer-size=4 \-m32 \-march=i386 \-mtune=generic \-fasynchronous-unwind-tables \-D_GNU_SOURCE \-fPIC \-fPIC \-I/usr/include/python2.4 \-c netlogger/parsers/modules/ks_wrap.c \-o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks_wrap.o gcc \-pthread \-fno-strict-aliasing \-DNDEBUG \-O2 \-g \-pipe \-Wall \-Wp,-D_FORTIFY_SOURCE=2 \-fexceptions \-fstack-protector \--param=ssp-buffer-size=4 \-m32 \-march=i386 \-mtune=generic \-fasynchronous-unwind-tables \-D_GNU_SOURCE \-fPIC \-fPIC \-I/usr/include/python2.4 \-c netlogger/parsers/modules/ks.c \-o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks.o netlogger/parsers/modules/ks.c: In function 'parse_one_event': netlogger/parsers/modules/ks.c:200: warning: suggest parentheses around assignment used as truth value netlogger/parsers/modules/ks.c:132: warning: unused variable 'attr_p' gcc \-pthread \-shared build/temp.linux-i686-2.4/netlogger/parsers/modules/ks_wrap.o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks.o \-o build/lib.linux-i686-2.4/netlogger/parsers/modules/_ks.so running build_scripts creating build/scripts-2.4 copying and adjusting scripts/nl_cfgmon \-> build/scripts-2.4 copying and adjusting scripts/nl_check \-> build/scripts-2.4 copying and adjusting scripts/nl_cpuprobe \-> build/scripts-2.4 copying and adjusting scripts/nl_csv \-> build/scripts-2.4 copying and adjusting scripts/nl_date \-> build/scripts-2.4 copying and adjusting scripts/nl_dbquery \-> build/scripts-2.4 copying and adjusting scripts/nl_findbottleneck \-> build/scripts-2.4 copying and adjusting scripts/nl_findmissing \-> build/scripts-2.4 copying and adjusting scripts/nl_ganglia \-> build/scripts-2.4 copying and adjusting scripts/nl_interval \-> build/scripts-2.4 copying and adjusting scripts/nl_lifeline \-> build/scripts-2.4 copying and adjusting scripts/nl_loader \-> build/scripts-2.4 copying and adjusting scripts/nl_notify \-> build/scripts-2.4 copying and adjusting scripts/nl_parser \-> build/scripts-2.4 copying and adjusting scripts/nl_pipeline \-> build/scripts-2.4 copying and adjusting scripts/nl_query \-> build/scripts-2.4 copying and adjusting scripts/nl_tbl \-> build/scripts-2.4 copying and adjusting scripts/nl_view \-> build/scripts-2.4 copying and adjusting scripts/nl_wflowgen \-> build/scripts-2.4 copying and adjusting scripts/nl_write \-> build/scripts-2.4 copying and adjusting scripts/netlogd \-> build/scripts-2.4 copying and adjusting scripts/nagios/nl_check_pipeline \-> build/scripts-2.4 changing mode of build/scripts-2.4/nl_cfgmon from 644 to 755 changing mode of build/scripts-2.4/nl_check from 644 to 755 changing mode of build/scripts-2.4/nl_cpuprobe from 644 to 755 changing mode of build/scripts-2.4/nl_csv from 644 to 755 changing mode of build/scripts-2.4/nl_date from 644 to 755 changing mode of build/scripts-2.4/nl_dbquery from 644 to 755 changing mode of build/scripts-2.4/nl_findbottleneck from 644 to 755 changing mode of build/scripts-2.4/nl_findmissing from 644 to 755 changing mode of build/scripts-2.4/nl_ganglia from 644 to 755 changing mode of build/scripts-2.4/nl_interval from 644 to 755 changing mode of build/scripts-2.4/nl_lifeline from 644 to 755 changing mode of build/scripts-2.4/nl_loader from 644 to 755 changing mode of build/scripts-2.4/nl_notify from 644 to 755 changing mode of build/scripts-2.4/nl_parser from 644 to 755 changing mode of build/scripts-2.4/nl_pipeline from 644 to 755 changing mode of build/scripts-2.4/nl_query from 644 to 755 changing mode of build/scripts-2.4/nl_tbl from 644 to 755 changing mode of build/scripts-2.4/nl_view from 644 to 755 changing mode of build/scripts-2.4/nl_wflowgen from 644 to 755 changing mode of build/scripts-2.4/nl_write from 644 to 755 changing mode of build/scripts-2.4/netlogd from 644 to 755 changing mode of build/scripts-2.4/nl_check_pipeline from 644 to 755
$ copy [gridftp.py|^gridftp.py] netlogger/parsers $ sudo python setup.py build running build running build_py copying netlogger/parsers/gridftp.py \-> build/lib.linux-i686-2.4/netlogger/parsers running build_ext running build_scripts
$ sudo /usr/bin/python setup.py install running install running bdist_egg running egg_info writing requirements to netlogger.egg-info/requires.txt writing netlogger.egg-info/PKG-INFO writing top-level names to netlogger.egg-info/top_level.txt writing dependency_links to netlogger.egg-info/dependency_links.txt reading manifest file 'netlogger.egg-info/SOURCES.txt' reading manifest template 'MANIFEST.in' warning: no previously-included files found matching 'scripts/nl_*.py' warning: no files found matching '*.gz' under directory 'extra' writing manifest file 'netlogger.egg-info/SOURCES.txt' installing library code to build/bdist.linux-i686/egg running install_lib running build_py running build_ext creating build/bdist.linux-i686/egg creating build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/__init__.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/bpize.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/configobj.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/logutil.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/nlapi.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/nlganglia.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/nllog.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/pipeline.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/talktome.py -> build/bdist.linux-i686/egg/netlogger copying build/lib.linux-i686-2.4/netlogger/util.py -> build/bdist.linux-i686/egg/netlogger creating build/bdist.linux-i686/egg/netlogger/parsers copying build/lib.linux-i686-2.4/netlogger/parsers/__init__.py -> build/bdist.linux-i686/egg/netlogger/parsers copying build/lib.linux-i686-2.4/netlogger/parsers/base.py -> build/bdist.linux-i686/egg/netlogger/parsers copying build/lib.linux-i686-2.4/netlogger/parsers/config.py -> build/bdist.linux-i686/egg/netlogger/parsers copying build/lib.linux-i686-2.4/netlogger/parsers/nlparser.py -> build/bdist.linux-i686/egg/netlogger/parsers copying build/lib.linux-i686-2.4/netlogger/parsers/nlreadline.py -> build/bdist.linux-i686/egg/netlogger/parsers creating build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/__init__.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/bestman.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/bp.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/condorxml.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/csa_acct.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/dynamic.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/generic.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gk.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gridftp.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gridftp_auth.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/jobstate.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/kickstart.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/ks.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/pbs.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/sge.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/sge_rpt.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/wsgram.py -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/modules/_ks.so -> build/bdist.linux-i686/egg/netlogger/parsers/modules copying build/lib.linux-i686-2.4/netlogger/parsers/gridftp.py -> build/bdist.linux-i686/egg/netlogger/parsers creating build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/__init__.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/bottleneck.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/filemon.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/histogram.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/lifeline.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/loader.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/loaderConfig.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/nlloader.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/schema.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/startend.py -> build/bdist.linux-i686/egg/netlogger/analysis copying build/lib.linux-i686-2.4/netlogger/analysis/wflowgen.py -> build/bdist.linux-i686/egg/netlogger/analysis creating build/bdist.linux-i686/egg/netlogger/analysis/query copying build/lib.linux-i686-2.4/netlogger/analysis/query/__init__.py -> build/bdist.linux-i686/egg/netlogger/analysis/query copying build/lib.linux-i686-2.4/netlogger/analysis/query/base.py -> build/bdist.linux-i686/egg/netlogger/analysis/query copying build/lib.linux-i686-2.4/netlogger/analysis/query/describe.py -> build/bdist.linux-i686/egg/netlogger/analysis/query copying build/lib.linux-i686-2.4/netlogger/analysis/query/grep.py -> build/bdist.linux-i686/egg/netlogger/analysis/query copying build/lib.linux-i686-2.4/netlogger/analysis/schema.conf -> build/bdist.linux-i686/egg/netlogger/analysis byte-compiling build/bdist.linux-i686/egg/netlogger/__init__.py to __init__.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/bpize.py to bpize.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/configobj.py to configobj.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/logutil.py to logutil.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/nlapi.py to nlapi.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/nlganglia.py to nlganglia.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/nllog.py to nllog.pyc File "build/bdist.linux-i686/egg/netlogger/nllog.py", line 103 yield ^ SyntaxError: invalid syntax byte-compiling build/bdist.linux-i686/egg/netlogger/pipeline.py to pipeline.pyc SyntaxError: ('future feature with_statement is not defined',) byte-compiling build/bdist.linux-i686/egg/netlogger/talktome.py to talktome.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/util.py to util.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/__init__.py to __init__.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/base.py to base.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/config.py to config.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/nlparser.py to nlparser.pyc File "build/bdist.linux-i686/egg/netlogger/parsers/nlparser.py", line 107 with nllog.logged(self.log, "addEofMarker", ^ SyntaxError: invalid syntax byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/nlreadline.py to nlreadline.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/__init__.py to __init__.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/bestman.py to bestman.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/bp.py to bp.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/condorxml.py to condorxml.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/csa_acct.py to csa_acct.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/dynamic.py to dynamic.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/generic.py to generic.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/gk.py to gk.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/gridftp.py to gridftp.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/gridftp_auth.py to gridftp_auth.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/jobstate.py to jobstate.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/kickstart.py to kickstart.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/ks.py to ks.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/pbs.py to pbs.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/sge.py to sge.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/sge_rpt.py to sge_rpt.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/wsgram.py to wsgram.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/gridftp.py to gridftp.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/__init__.py to __init__.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/bottleneck.py to bottleneck.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/filemon.py to filemon.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/histogram.py to histogram.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/lifeline.py to lifeline.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/loader.py to loader.pyc File "build/bdist.linux-i686/egg/netlogger/analysis/loader.py", line 573 with nllog.logged(log, "drop.database"): ^ SyntaxError: invalid syntax byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/loaderConfig.py to loaderConfig.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/nlloader.py to nlloader.pyc File "build/bdist.linux-i686/egg/netlogger/analysis/nlloader.py", line 209 with nllog.logged(self.log, "spin." + why): ^ SyntaxError: invalid syntax byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/schema.py to schema.pyc File "build/bdist.linux-i686/egg/netlogger/analysis/schema.py", line 90 with nllog.logged(self.log, event="schema.init"): ^ SyntaxError: invalid syntax byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/startend.py to startend.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/wflowgen.py to wflowgen.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/query/__init__.py to __init__.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/query/base.py to base.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/query/describe.py to describe.pyc byte-compiling build/bdist.linux-i686/egg/netlogger/analysis/query/grep.py to grep.pyc creating stub loader for netlogger/parsers/modules/_ks.so byte-compiling build/bdist.linux-i686/egg/netlogger/parsers/modules/_ks.py to _ks.pyc creating build/bdist.linux-i686/egg/EGG-INFO installing scripts to build/bdist.linux-i686/egg/EGG-INFO/scripts running install_scripts running build_scripts creating build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_cfgmon -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_check -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_cpuprobe -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_csv -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_date -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_dbquery -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_findbottleneck -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_findmissing -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_ganglia -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_interval -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_lifeline -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_loader -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_notify -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_parser -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_pipeline -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_query -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_tbl -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_view -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_wflowgen -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_write -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/netlogd -> build/bdist.linux-i686/egg/EGG-INFO/scripts copying build/scripts-2.4/nl_check_pipeline -> build/bdist.linux-i686/egg/EGG-INFO/scripts changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_cfgmon to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_check to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_cpuprobe to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_csv to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_date to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_dbquery to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_findbottleneck to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_findmissing to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_ganglia to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_interval to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_lifeline to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_loader to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_notify to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_parser to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_pipeline to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_query to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_tbl to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_view to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_wflowgen to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_write to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/netlogd to 755 changing mode of build/bdist.linux-i686/egg/EGG-INFO/scripts/nl_check_pipeline to 755 writing netlogger.egg-info/native_libs.txt copying netlogger.egg-info/PKG-INFO -> build/bdist.linux-i686/egg/EGG-INFO copying netlogger.egg-info/SOURCES.txt -> build/bdist.linux-i686/egg/EGG-INFO copying netlogger.egg-info/dependency_links.txt -> build/bdist.linux-i686/egg/EGG-INFO copying netlogger.egg-info/native_libs.txt -> build/bdist.linux-i686/egg/EGG-INFO copying netlogger.egg-info/requires.txt -> build/bdist.linux-i686/egg/EGG-INFO copying netlogger.egg-info/top_level.txt -> build/bdist.linux-i686/egg/EGG-INFO zip_safe flag not set; analyzing archive contents... netlogger.parsers.config: module references __path__ creating 'dist/netlogger-4.1.0-py2.4-linux-i686.egg' and adding 'build/bdist.linux-i686/egg' to it removing 'build/bdist.linux-i686/egg' (and everything under it) Processing netlogger-4.1.0-py2.4-linux-i686.egg removing '/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg' (and everything under it) creating /usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg Extracting netlogger-4.1.0-py2.4-linux-i686.egg to /usr/lib/python2.4/site-packages File "/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg/netlogger/nllog.py", line 103 yield ^ SyntaxError: invalid syntax SyntaxError: ('future feature with_statement is not defined',) File "/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg/netlogger/parsers/nlparser.py", line 107 with nllog.logged(self.log, "addEofMarker", ^ SyntaxError: invalid syntax File "/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg/netlogger/analysis/loader.py", line 573 with nllog.logged(log, "drop.database"): ^ SyntaxError: invalid syntax File "/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg/netlogger/analysis/nlloader.py", line 209 with nllog.logged(self.log, "spin." + why): ^ SyntaxError: invalid syntax File "/usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg/netlogger/analysis/schema.py", line 90 with nllog.logged(self.log, event="schema.init"): ^ SyntaxError: invalid syntax netlogger 4.1.0 is already the active version in easy-install.pth Installing nl_parser script to /usr/bin Installing nl_lifeline script to /usr/bin Installing nl_check script to /usr/bin Installing nl_loader script to /usr/bin Installing nl_ganglia script to /usr/bin Installing nl_cpuprobe script to /usr/bin Installing nl_tbl script to /usr/bin Installing nl_pipeline script to /usr/bin Installing nl_notify script to /usr/bin Installing nl_view script to /usr/bin Installing nl_interval script to /usr/bin Installing nl_check_pipeline script to /usr/bin Installing netlogd script to /usr/bin Installing nl_findbottleneck script to /usr/bin Installing nl_query script to /usr/bin Installing nl_dbquery script to /usr/bin Installing nl_wflowgen script to /usr/bin Installing nl_write script to /usr/bin Installing nl_csv script to /usr/bin Installing nl_date script to /usr/bin Installing nl_findmissing script to /usr/bin Installing nl_cfgmon script to /usr/bin Installed /usr/lib/python2.4/site-packages/netlogger-4.1.0-py2.4-linux-i686.egg Processing dependencies for netlogger==4.1.0
I then tried to use python2.5 from afs, which for me was visible under /opt/TWWfsw/bin/python. Mysql and postgresSQL modules were already present so I ran the command:
bash $export PYTHONPATH=/afs/slac.stanford.edu/u/sg/fahad/netlogger_install/ && sudo /opt/TWWfsw/bin/python setup.py install \--prefix=/afs/slac.stanford.edu/u/sg/fahad/netlogger_install/
This command, is supposed to first export the PYTHONPATH variable and then using the python from afs run the setup.py script. The prefix variable which can also be replaced by the home variable is supposed to point to the location where installation needs to be done.
On running this command, I received and error, which indicated that the directory passed in the prefix command was not set for .pth files.
After reading a lot of blogs and forums, I created a file under my home directory ~./pydistutils.cfg and placed the following in there:
\[install\] install_lib = /afs/slac/u/sg/fahad/lib/python2.5 \# This next line is optional but often quite useful; it directs EasyInstall \# and the distutils to install scripts in the user's "bin" directory. For \# Mac OS X framework Python builds, you should use /usr/local/bin instead, \# because neither \~/bin nor the default script installation location are on \# the system PATH. \# install_scripts = /afs/slac/u/sg/fahad/bin
All this did was to help me reduce the size of command to:
$ sudo /opt/TWWfsw/bin/python setup.py install
The error:
running install Checking .pth file support in /afs/slac/u/sg/fahad/lib/python2.5/ /opt/TWWfsw/bin/python \-E \-c pass TEST FAILED: /afs/slac/u/sg/fahad/lib/python2.5/ does NOT support .pth files error: bad install directory or PYTHONPATH You are attempting to install a package to a directory that is not on PYTHONPATH and which Python does not read ".pth" files from. The installation directory you specified (via \--install-dir, \--prefix, or the distutils default setting) was: /afs/slac/u/sg/fahad/lib/python2.5/ and your PYTHONPATH environment variable currently contains: '' Here are some of your options for correcting the problem: \* You can choose a different installation directory, i.e., one that is on PYTHONPATH or supports .pth files \* You can add the installation directory to the PYTHONPATH environment variable. (It must then also be on PYTHONPATH whenever you run Python and want to use the package(s) you are installing.) \* You can set up the installation directory to support ".pth" files by using one of the approaches described here: http://peak.telecommunity.com/EasyInstall.html#custom-installation-locations Please make the appropriate changes for your system and try again.
I then tried to create a virtual-python, as indicated here: http://peak.telecommunity.com/EasyInstall.html#custom-installation-locations
I used the script here: http://peak.telecommunity.com/dist/virtual-python.py, did a wget and ran it.
$ sudo /opt/TWWfsw/bin/python virtual-python.py
This created python links in my local directory under bin for python 2.5.
The next step was to install setup tools.
I followed the installation procedure from here:
http://pypi.python.org/pypi/setuptools
But installing them required access on afs space.
So I ran:
$ sh setuptools-0.6c11-py2.5.egg \--prefix=\~
Failing here, I went on to use svn for installing netlogger.