NetLogger Installation

Intro

A detailed explanation of NetLogger installation procedure can be found here:

http://acs.lbl.gov/NetLogger-releases/doc/trunk/manual.html#python_install

Note: I am doing python install, to keep things simple and to avoid security problems at slac. The other option is perl, but since all the code developed by Dan Gunter will be in python, it will be easier to integrate.

Note netlogger requires python version of 2.4 and greater.

You can check your python version by using -V option:

$ python \-V

Pre-requisite packages

You might require python's setup tools if not installed already. They can be obtained from python setuptools.

As a dependency package "mysql-devel" may be required, if not installed already. The easiest way to do this is "yum install mysql-devel".

MySQLdb Interface to Python

In order to install MySQLdb, easy_install is supposed to be the easiest method, but on running the command:

$ easy_install MySQLdb

I received the error, that no such Library was found. So I installed the lib using source.

From source forge I got the direct link to Mysql

$ /usr/bin/wget [http://downloads.sourceforge.net/project/mysql-python/mysql-python-test/1.2.3c1/MySQL-python-1.2.3c1.tar.gz?use_mirror=hivelocity]

$ gunzip MySQL-python-1.2.3c1.tar.gz

$ tar \-xvf MySQL-python-1.2.3c1.tar

$ cd MySQL-python-1.2.3c1

$ python setup.py build

$ python setup.py install

PostgresSQL Interface to Python

For installing Postgre I used easy_install. However on running :

$ sudo easy_install psycopg2

I received an error

error: Setup script exited with error: No such file or directory

So I did:

$ sudo easy_install -eb. psycopg2

and got the path where pgycopg2 was downloaded and extracted.

$ cd ./psycopg2/

$ sudo python -c "import setuptools; execfile('setup.py')" bdist_egg

I got the following error:

warning: manifest_maker: standard file '-c' not found

error: No such file or directory

I then decided to make sure postgre was installed and updated, so I ran

$ sudo yum -y install postgresql postgresql-server

$ sudo python -c "import setuptools; execfile('setup.py')" bdist_egg

I got the following error again:

warning: manifest_maker: standard file '-c' not found

error: No such file or directory

This was resolved by using yum to install python interface:

$ sudo yum install postgresql-python

Installing NetLogger from Source

See here: http://confluence.slac.stanford.edu/display/IEPM/Netlogger Installation Failed Attempts

Installing Netlogger from svn

Link to the svn can be found here:

http://acs.lbl.gov/NetLoggerWiki/index.php/Downloads#Subversion

The procedure I followed, was pretty much standard.

I created a directory netlogger_svn_install, and then did a svn checkout to get the python version for netlogger.

$ mkdir netlogger_svn_install

$ cd netlogger_svn_install/

$ svn checkout https://bosshog.lbl.gov/repos/netlogger/trunk/python/ ./

$ cp gridftp.py netlogger_svn_install/netlogger/parsers/modules/
 

This module is required for handling a bug in GridFTP logs, with timestamp.

bash-3.2$ sudo python setup.py build
Password:
running build
running build_py
creating build
creating build/lib.linux-i686-2.4
creating build/lib.linux-i686-2.4/netlogger
copying netlogger/config_verify.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nlganglia.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/__init__.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/dispatch.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/info_broker.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/configobj.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nlapi.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/pipeline.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nfd.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nldate.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nllog.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/nlstatus.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/util.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/magicdate.py \-> build/lib.linux-i686-2.4/netlogger
copying netlogger/version.py \-> build/lib.linux-i686-2.4/netlogger
creating build/lib.linux-i686-2.4/netlogger/parsers
copying netlogger/parsers/base.py \-> build/lib.linux-i686-2.4/netlogger/parsers
copying netlogger/parsers/nlreadline.py \-> build/lib.linux-i686-2.4/netlogger/parsers
copying netlogger/parsers/__init__.py \-> build/lib.linux-i686-2.4/netlogger/parsers
copying netlogger/parsers/config.py \-> build/lib.linux-i686-2.4/netlogger/parsers
copying netlogger/parsers/nlparser.py \-> build/lib.linux-i686-2.4/netlogger/parsers
creating build/lib.linux-i686-2.4/netlogger/pegasus
copying netlogger/pegasus/kickstart_hdr.py \-> build/lib.linux-i686-2.4/netlogger/pegasus
copying netlogger/pegasus/__init__.py \-> build/lib.linux-i686-2.4/netlogger/pegasus
copying netlogger/pegasus/nl_troubleshooting.py \-> build/lib.linux-i686-2.4/netlogger/pegasus
copying netlogger/pegasus/extractAndgetCumul.py \-> build/lib.linux-i686-2.4/netlogger/pegasus
creating build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/bestman.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/hsi_ndapi.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/kickstart.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/__init__.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/condor_dag.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/globus_condor.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/gridftp.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/wsgram.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/csa_acct.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/bp.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/gk.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/sge_rpt.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/hsi_xfer.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/jobstate.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/generic.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/ks.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/sge.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/vmstat.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/gridftp_auth.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/gram_acct.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/gensim.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/netstat.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/dynamic.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
copying netlogger/parsers/modules/pbs.py \-> build/lib.linux-i686-2.4/netlogger/parsers/modules
creating build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/wflowgen.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/filemon.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/bottleneck.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/loaderConfig.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/histogram.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/__init__.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/nlloader.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/schema.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/startend.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/loader.py \-> build/lib.linux-i686-2.4/netlogger/analysis
copying netlogger/analysis/lifeline.py \-> build/lib.linux-i686-2.4/netlogger/analysis
creating build/lib.linux-i686-2.4/netlogger/tests
copying netlogger/tests/__init__.py \-> build/lib.linux-i686-2.4/netlogger/tests
copying netlogger/tests/shared.py \-> build/lib.linux-i686-2.4/netlogger/tests
creating build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseKickstart.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseGridftp.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseHsiNdapi.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseCondorDag.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseCsaAcct.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseSgeRpt.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/__init__.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testNlPipeline.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseHsiXfer.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testDatabase.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testLoader.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseJobstate.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testNfd.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/all.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseSge.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseGridftpAuth.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseGramAcct.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testUtil.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseDynamic.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParsePBS.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParsers.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParserConfig.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
copying netlogger/tests/component/testParseBestman.py \-> build/lib.linux-i686-2.4/netlogger/tests/component
package init file 'netlogger/tests/data/__init__.py' not found (or not a regular file)
creating build/lib.linux-i686-2.4/netlogger/tests/data
copying netlogger/tests/data/fake_pipeline_prog.py \-> build/lib.linux-i686-2.4/netlogger/tests/data
creating build/lib.linux-i686-2.4/netlogger/tests/stress
copying netlogger/tests/stress/testUtil.py \-> build/lib.linux-i686-2.4/netlogger/tests/stress
copying netlogger/tests/stress/__init__.py \-> build/lib.linux-i686-2.4/netlogger/tests/stress
copying netlogger/tests/stress/shared.py \-> build/lib.linux-i686-2.4/netlogger/tests/stress
copying netlogger/tests/stress/testLoader.py \-> build/lib.linux-i686-2.4/netlogger/tests/stress
creating build/lib.linux-i686-2.4/netlogger/tests/system
copying netlogger/tests/system/all.py \-> build/lib.linux-i686-2.4/netlogger/tests/system
copying netlogger/tests/system/testFullPipeline.py \-> build/lib.linux-i686-2.4/netlogger/tests/system
copying netlogger/tests/system/__init__.py \-> build/lib.linux-i686-2.4/netlogger/tests/system
copying netlogger/tests/system/testPegasusLoad.py \-> build/lib.linux-i686-2.4/netlogger/tests/system
copying netlogger/tests/system/testScripts.py \-> build/lib.linux-i686-2.4/netlogger/tests/system
creating build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testParseGridftp.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testIncConfigObj.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testParseGlobusCondor.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testLoaderConfig.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testNetlogd.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/__init__.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testDispatch.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testNlLoader.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testDateParsing.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testPegasusHdr.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testLoader.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testNfd.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testParseGatekeeper.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/all.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testParseVmstat.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testNllog.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testParseDynamic.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testStartend.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testNlParser.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
copying netlogger/tests/unit/testFIFODict.py \-> build/lib.linux-i686-2.4/netlogger/tests/unit
creating build/lib.linux-i686-2.4/netlogger/data
copying netlogger/data/schema.conf \-> build/lib.linux-i686-2.4/netlogger/data
copying netlogger/data/nl_loader.spec \-> build/lib.linux-i686-2.4/netlogger/data
copying netlogger/data/nl_parser.spec \-> build/lib.linux-i686-2.4/netlogger/data
package init file 'netlogger/tests/data/__init__.py' not found (or not a regular file)
running build_ext
building 'netlogger/parsers/modules/_ks' extension
creating build/temp.linux-i686-2.4
creating build/temp.linux-i686-2.4/netlogger
creating build/temp.linux-i686-2.4/netlogger/parsers
creating build/temp.linux-i686-2.4/netlogger/parsers/modules
gcc \-pthread \-fno-strict-aliasing \-DNDEBUG \-O2 \-g \-pipe \-Wall \-Wp,-D_FORTIFY_SOURCE=2 \-fexceptions \-fstack-protector \--param=ssp-buffer-size=4 \-m32 \-march=i386 \-mtune=generic \-fasynchronous-unwind-tables \-D_GNU_SOURCE \-fPIC \-fPIC \-I/usr/include/python2.4 \-c netlogger/parsers/modules/ks_wrap.c \-o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks_wrap.o
gcc \-pthread \-fno-strict-aliasing \-DNDEBUG \-O2 \-g \-pipe \-Wall \-Wp,-D_FORTIFY_SOURCE=2 \-fexceptions \-fstack-protector \--param=ssp-buffer-size=4 \-m32 \-march=i386 \-mtune=generic \-fasynchronous-unwind-tables \-D_GNU_SOURCE \-fPIC \-fPIC \-I/usr/include/python2.4 \-c netlogger/parsers/modules/ks.c \-o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks.o
netlogger/parsers/modules/ks.c: In function 'parse_one_event':
netlogger/parsers/modules/ks.c:200: warning: suggest parentheses around assignment used as truth value
netlogger/parsers/modules/ks.c:132: warning: unused variable 'attr_p'
gcc \-pthread \-shared build/temp.linux-i686-2.4/netlogger/parsers/modules/ks_wrap.o build/temp.linux-i686-2.4/netlogger/parsers/modules/ks.o \-o build/lib.linux-i686-2.4/netlogger/parsers/modules/_ks.so
running build_scripts
creating build/scripts-2.4
copying and adjusting scripts/nl_lifeline \-> build/scripts-2.4
copying and adjusting scripts/nl_cpu \-> build/scripts-2.4
copying and adjusting scripts/nl_wflowgen \-> build/scripts-2.4
copying and adjusting scripts/nl_dup \-> build/scripts-2.4
copying and adjusting scripts/nl_config_verify \-> build/scripts-2.4
copying and adjusting scripts/nl_write \-> build/scripts-2.4
copying and adjusting scripts/nl_csv \-> build/scripts-2.4
copying and adjusting scripts/nl_findbottleneck \-> build/scripts-2.4
copying and adjusting scripts/nl_parser \-> build/scripts-2.4
copying and adjusting scripts/nl_snoop \-> build/scripts-2.4
copying and adjusting scripts/nl_actions \-> build/scripts-2.4
copying and adjusting scripts/nl_check_pipeline \-> build/scripts-2.4
copying and adjusting scripts/nl_ganglia \-> build/scripts-2.4
copying and adjusting scripts/nl_pipeline \-> build/scripts-2.4
copying and adjusting scripts/nl_loader \-> build/scripts-2.4
copying and adjusting scripts/nl_gap \-> build/scripts-2.4
copying and adjusting scripts/nl_notify \-> build/scripts-2.4
copying and adjusting scripts/nl_cfgmon \-> build/scripts-2.4
copying and adjusting scripts/nl_findmissing \-> build/scripts-2.4
copying and adjusting scripts/nl_view \-> build/scripts-2.4
copying and adjusting scripts/nl_dbquery \-> build/scripts-2.4
copying and adjusting scripts/nl_date \-> build/scripts-2.4
copying and adjusting scripts/nl_check \-> build/scripts-2.4
copying and adjusting scripts/nl_cpuprobe \-> build/scripts-2.4
copying and adjusting scripts/nl_load \-> build/scripts-2.4
copying and adjusting scripts/nl_status \-> build/scripts-2.4
copying and adjusting scripts/nl_interval \-> build/scripts-2.4
copying and adjusting scripts/netlogd \-> build/scripts-2.4
copying and adjusting scripts/pegasus/nl_pegload \-> build/scripts-2.4
copying and adjusting scripts/pegasus/nl_pegasus_hdr \-> build/scripts-2.4
changing mode of build/scripts-2.4/nl_lifeline from 644 to 755
changing mode of build/scripts-2.4/nl_cpu from 644 to 755
changing mode of build/scripts-2.4/nl_wflowgen from 644 to 755
changing mode of build/scripts-2.4/nl_dup from 644 to 755
changing mode of build/scripts-2.4/nl_config_verify from 644 to 755
changing mode of build/scripts-2.4/nl_write from 644 to 755
changing mode of build/scripts-2.4/nl_csv from 644 to 755
changing mode of build/scripts-2.4/nl_findbottleneck from 644 to 755
changing mode of build/scripts-2.4/nl_parser from 644 to 755
changing mode of build/scripts-2.4/nl_snoop from 644 to 755
changing mode of build/scripts-2.4/nl_actions from 644 to 755
changing mode of build/scripts-2.4/nl_check_pipeline from 644 to 755
changing mode of build/scripts-2.4/nl_ganglia from 644 to 755
changing mode of build/scripts-2.4/nl_pipeline from 644 to 755
changing mode of build/scripts-2.4/nl_loader from 644 to 755
changing mode of build/scripts-2.4/nl_gap from 644 to 755
changing mode of build/scripts-2.4/nl_notify from 644 to 755
changing mode of build/scripts-2.4/nl_cfgmon from 644 to 755
changing mode of build/scripts-2.4/nl_findmissing from 644 to 755
changing mode of build/scripts-2.4/nl_view from 644 to 755
changing mode of build/scripts-2.4/nl_dbquery from 644 to 755
changing mode of build/scripts-2.4/nl_date from 644 to 755
changing mode of build/scripts-2.4/nl_check from 644 to 755
changing mode of build/scripts-2.4/nl_cpuprobe from 644 to 755
changing mode of build/scripts-2.4/nl_load from 644 to 755
changing mode of build/scripts-2.4/nl_status from 644 to 755
changing mode of build/scripts-2.4/nl_interval from 644 to 755
changing mode of build/scripts-2.4/netlogd from 644 to 755
changing mode of build/scripts-2.4/nl_pegload from 644 to 755
changing mode of build/scripts-2.4/nl_pegasus_hdr from 644 to 755

Build looks fine, now the install.

bash-3.2$ sudo python setup.py install
running install
running build
running build_py
package init file 'netlogger/tests/data/__init__.py' not found (or not a regular file)
package init file 'netlogger/tests/data/__init__.py' not found (or not a regular file)
running build_ext
running build_scripts
running install_lib
copying build/lib.linux-i686-2.4/netlogger/config_verify.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nlganglia.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/dispatch.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/info_broker.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/configobj.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nlapi.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/pipeline.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nfd.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nldate.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nllog.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/nlstatus.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/util.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/magicdate.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/version.py \-> /usr/lib/python2.4/site-packages/netlogger
copying build/lib.linux-i686-2.4/netlogger/parsers/base.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers
copying build/lib.linux-i686-2.4/netlogger/parsers/nlreadline.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers
copying build/lib.linux-i686-2.4/netlogger/parsers/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers
copying build/lib.linux-i686-2.4/netlogger/parsers/config.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers
copying build/lib.linux-i686-2.4/netlogger/parsers/nlparser.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/bestman.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/hsi_ndapi.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/kickstart.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/condor_dag.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/globus_condor.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gridftp.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/wsgram.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/csa_acct.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/bp.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gk.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/sge_rpt.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/hsi_xfer.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/jobstate.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/generic.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/ks.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/sge.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/vmstat.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gridftp_auth.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gram_acct.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/gensim.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/netstat.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/dynamic.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/pbs.py \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/parsers/modules/_ks.so \-> /usr/lib/python2.4/site-packages/netlogger/parsers/modules
copying build/lib.linux-i686-2.4/netlogger/pegasus/kickstart_hdr.py \-> /usr/lib/python2.4/site-packages/netlogger/pegasus
copying build/lib.linux-i686-2.4/netlogger/pegasus/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/pegasus
copying build/lib.linux-i686-2.4/netlogger/pegasus/nl_troubleshooting.py \-> /usr/lib/python2.4/site-packages/netlogger/pegasus
copying build/lib.linux-i686-2.4/netlogger/pegasus/extractAndgetCumul.py \-> /usr/lib/python2.4/site-packages/netlogger/pegasus
copying build/lib.linux-i686-2.4/netlogger/analysis/wflowgen.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/filemon.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/bottleneck.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/loaderConfig.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/histogram.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/nlloader.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/schema.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/startend.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/loader.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/analysis/lifeline.py \-> /usr/lib/python2.4/site-packages/netlogger/analysis
copying build/lib.linux-i686-2.4/netlogger/tests/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/tests
copying build/lib.linux-i686-2.4/netlogger/tests/shared.py \-> /usr/lib/python2.4/site-packages/netlogger/tests
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseKickstart.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseGridftp.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseHsiNdapi.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseCondorDag.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseCsaAcct.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseSgeRpt.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testNlPipeline.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseHsiXfer.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testDatabase.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testLoader.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseJobstate.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testNfd.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/all.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseSge.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseGridftpAuth.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseGramAcct.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testUtil.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseDynamic.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParsePBS.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParsers.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParserConfig.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/component/testParseBestman.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/component
copying build/lib.linux-i686-2.4/netlogger/tests/data/fake_pipeline_prog.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/data
copying build/lib.linux-i686-2.4/netlogger/tests/stress/testUtil.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/stress
copying build/lib.linux-i686-2.4/netlogger/tests/stress/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/stress
copying build/lib.linux-i686-2.4/netlogger/tests/stress/shared.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/stress
copying build/lib.linux-i686-2.4/netlogger/tests/stress/testLoader.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/stress
copying build/lib.linux-i686-2.4/netlogger/tests/system/all.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/system
copying build/lib.linux-i686-2.4/netlogger/tests/system/testFullPipeline.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/system
copying build/lib.linux-i686-2.4/netlogger/tests/system/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/system
copying build/lib.linux-i686-2.4/netlogger/tests/system/testPegasusLoad.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/system
copying build/lib.linux-i686-2.4/netlogger/tests/system/testScripts.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/system
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testParseGridftp.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testIncConfigObj.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testParseGlobusCondor.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testLoaderConfig.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testNetlogd.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/__init__.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testDispatch.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testNlLoader.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testDateParsing.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testPegasusHdr.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testLoader.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testNfd.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testParseGatekeeper.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/all.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testParseVmstat.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testNllog.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testParseDynamic.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testStartend.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testNlParser.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/tests/unit/testFIFODict.py \-> /usr/lib/python2.4/site-packages/netlogger/tests/unit
copying build/lib.linux-i686-2.4/netlogger/data/schema.conf \-> /usr/lib/python2.4/site-packages/netlogger/data
copying build/lib.linux-i686-2.4/netlogger/data/nl_loader.spec \-> /usr/lib/python2.4/site-packages/netlogger/data
copying build/lib.linux-i686-2.4/netlogger/data/nl_parser.spec \-> /usr/lib/python2.4/site-packages/netlogger/data
byte-compiling /usr/lib/python2.4/site-packages/netlogger/config_verify.py to config_verify.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nlganglia.py to nlganglia.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/dispatch.py to dispatch.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/info_broker.py to info_broker.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/configobj.py to configobj.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nlapi.py to nlapi.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/pipeline.py to pipeline.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nfd.py to nfd.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nldate.py to nldate.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nllog.py to nllog.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/nlstatus.py to nlstatus.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/util.py to util.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/magicdate.py to magicdate.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/version.py to version.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/base.py to base.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/nlreadline.py to nlreadline.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/config.py to config.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/nlparser.py to nlparser.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/bestman.py to bestman.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/hsi_ndapi.py to hsi_ndapi.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/kickstart.py to kickstart.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/condor_dag.py to condor_dag.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/globus_condor.py to globus_condor.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/gridftp.py to gridftp.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/wsgram.py to wsgram.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/csa_acct.py to csa_acct.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/bp.py to bp.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/gk.py to gk.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/sge_rpt.py to sge_rpt.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/hsi_xfer.py to hsi_xfer.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/jobstate.py to jobstate.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/generic.py to generic.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/ks.py to ks.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/sge.py to sge.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/vmstat.py to vmstat.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/gridftp_auth.py to gridftp_auth.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/gram_acct.py to gram_acct.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/gensim.py to gensim.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/netstat.py to netstat.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/dynamic.py to dynamic.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/parsers/modules/pbs.py to pbs.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/pegasus/kickstart_hdr.py to kickstart_hdr.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/pegasus/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/pegasus/nl_troubleshooting.py to nl_troubleshooting.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/pegasus/extractAndgetCumul.py to extractAndgetCumul.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/wflowgen.py to wflowgen.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/filemon.py to filemon.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/bottleneck.py to bottleneck.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/loaderConfig.py to loaderConfig.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/histogram.py to histogram.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/nlloader.py to nlloader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/schema.py to schema.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/startend.py to startend.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/loader.py to loader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/analysis/lifeline.py to lifeline.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/shared.py to shared.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseKickstart.py to testParseKickstart.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseGridftp.py to testParseGridftp.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseHsiNdapi.py to testParseHsiNdapi.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseCondorDag.py to testParseCondorDag.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseCsaAcct.py to testParseCsaAcct.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseSgeRpt.py to testParseSgeRpt.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testNlPipeline.py to testNlPipeline.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseHsiXfer.py to testParseHsiXfer.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testDatabase.py to testDatabase.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testLoader.py to testLoader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseJobstate.py to testParseJobstate.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testNfd.py to testNfd.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/all.py to all.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseSge.py to testParseSge.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseGridftpAuth.py to testParseGridftpAuth.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseGramAcct.py to testParseGramAcct.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testUtil.py to testUtil.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseDynamic.py to testParseDynamic.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParsePBS.py to testParsePBS.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParsers.py to testParsers.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParserConfig.py to testParserConfig.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/component/testParseBestman.py to testParseBestman.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/data/fake_pipeline_prog.py to fake_pipeline_prog.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/stress/testUtil.py to testUtil.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/stress/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/stress/shared.py to shared.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/stress/testLoader.py to testLoader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/system/all.py to all.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/system/testFullPipeline.py to testFullPipeline.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/system/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/system/testPegasusLoad.py to testPegasusLoad.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/system/testScripts.py to testScripts.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testParseGridftp.py to testParseGridftp.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testIncConfigObj.py to testIncConfigObj.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testParseGlobusCondor.py to testParseGlobusCondor.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testLoaderConfig.py to testLoaderConfig.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testNetlogd.py to testNetlogd.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/__init__.py to \__init__.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testDispatch.py to testDispatch.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testNlLoader.py to testNlLoader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testDateParsing.py to testDateParsing.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testPegasusHdr.py to testPegasusHdr.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testLoader.py to testLoader.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testNfd.py to testNfd.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testParseGatekeeper.py to testParseGatekeeper.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/all.py to all.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testParseVmstat.py to testParseVmstat.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testNllog.py to testNllog.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testParseDynamic.py to testParseDynamic.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testStartend.py to testStartend.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testNlParser.py to testNlParser.pyc
byte-compiling /usr/lib/python2.4/site-packages/netlogger/tests/unit/testFIFODict.py to testFIFODict.pyc
running install_scripts
copying build/scripts-2.4/nl_lifeline \-> /usr/bin
copying build/scripts-2.4/nl_cpu \-> /usr/bin
copying build/scripts-2.4/nl_wflowgen \-> /usr/bin
copying build/scripts-2.4/nl_dup \-> /usr/bin
copying build/scripts-2.4/nl_config_verify \-> /usr/bin
copying build/scripts-2.4/nl_write \-> /usr/bin
copying build/scripts-2.4/nl_csv \-> /usr/bin
copying build/scripts-2.4/nl_findbottleneck \-> /usr/bin
copying build/scripts-2.4/nl_parser \-> /usr/bin
copying build/scripts-2.4/nl_snoop \-> /usr/bin
copying build/scripts-2.4/nl_actions \-> /usr/bin
copying build/scripts-2.4/nl_check_pipeline \-> /usr/bin
copying build/scripts-2.4/nl_ganglia \-> /usr/bin
copying build/scripts-2.4/nl_pipeline \-> /usr/bin
copying build/scripts-2.4/nl_loader \-> /usr/bin
copying build/scripts-2.4/nl_gap \-> /usr/bin
copying build/scripts-2.4/nl_notify \-> /usr/bin
copying build/scripts-2.4/nl_cfgmon \-> /usr/bin
copying build/scripts-2.4/nl_findmissing \-> /usr/bin
copying build/scripts-2.4/nl_view \-> /usr/bin
copying build/scripts-2.4/nl_dbquery \-> /usr/bin
copying build/scripts-2.4/nl_date \-> /usr/bin
copying build/scripts-2.4/nl_check \-> /usr/bin
copying build/scripts-2.4/nl_cpuprobe \-> /usr/bin
copying build/scripts-2.4/nl_load \-> /usr/bin
copying build/scripts-2.4/nl_status \-> /usr/bin
copying build/scripts-2.4/nl_interval \-> /usr/bin
copying build/scripts-2.4/netlogd \-> /usr/bin
copying build/scripts-2.4/nl_pegload \-> /usr/bin
copying build/scripts-2.4/nl_pegasus_hdr \-> /usr/bin
changing mode of /usr/bin/nl_lifeline to 755
changing mode of /usr/bin/nl_cpu to 755
changing mode of /usr/bin/nl_wflowgen to 755
changing mode of /usr/bin/nl_dup to 755
changing mode of /usr/bin/nl_config_verify to 755
changing mode of /usr/bin/nl_write to 755
changing mode of /usr/bin/nl_csv to 755
changing mode of /usr/bin/nl_findbottleneck to 755
changing mode of /usr/bin/nl_parser to 755
changing mode of /usr/bin/nl_snoop to 755
changing mode of /usr/bin/nl_actions to 755
changing mode of /usr/bin/nl_check_pipeline to 755
changing mode of /usr/bin/nl_ganglia to 755
changing mode of /usr/bin/nl_pipeline to 755
changing mode of /usr/bin/nl_loader to 755
changing mode of /usr/bin/nl_gap to 755
changing mode of /usr/bin/nl_notify to 755
changing mode of /usr/bin/nl_cfgmon to 755
changing mode of /usr/bin/nl_findmissing to 755
changing mode of /usr/bin/nl_view to 755
changing mode of /usr/bin/nl_dbquery to 755
changing mode of /usr/bin/nl_date to 755
changing mode of /usr/bin/nl_check to 755
changing mode of /usr/bin/nl_cpuprobe to 755
changing mode of /usr/bin/nl_load to 755
changing mode of /usr/bin/nl_status to 755
changing mode of /usr/bin/nl_interval to 755
changing mode of /usr/bin/netlogd to 755
changing mode of /usr/bin/nl_pegload to 755
changing mode of /usr/bin/nl_pegasus_hdr to 755

  • No labels